Table of Contents
D9412GV3/D7412GV3 | Program Entry Guide | 6.0
D# Enter Request?
Default:
No
Selection:
Yes or No
Yes
A Door RTE Event from this door
controller is sent to the control panel
for processing.
No
A Door RTE Event from this door
controller is not sent to the control
panel for processing.
This program item determines if RTE Events are sent
to the control panel for processing memory, printing,
and remote reporting.
RTE Events require D# Access Granted
to be programmed as Yes.
D# Exit Request?
Default:
No
Selection:
Yes or No
Yes
A Door REX Event from this door
controller is sent to the control panel
for processing.
A Door REX Event from this door
No
controller is not sent to the control
panel for processing.
This program item determines if REX Events are sent
to the control panel for processing memory, printing,
and remote reporting.
REX Events require D# Access Granted
to be programmed as Yes.