L## Default Text; L## Change Skeds; L## C Function 128 [Through 143]; L## Force Arm - Bosch D9412G Program Entry Manual

Table of Contents
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
-
D1255 command center displays a
sequential count after each point is activated
and restored as well as the text for the point.
-
The D1255 command center displays ALL
PNTS TESTED.
If enabled in Routing, Service Start and
-
Service End are reported at the central
station receiver for the beginning and end of
the test.
Point 128 and Point 248 appear as missing. This is
normal. These points are used for supervising the
Zonex bus 1 (Point 128) and Zonex bus 2 (Point
248). If these points indicate a short, the Zonex bus
has a fault.
Extra points can be viewed using this function. Extra
points occur under two conditions: an extra point is
a point wired electrically to the Zonex bus with a
P### Point Index
blank
exist for the same Zonex address.

L## Default Text

Program Record Sheet
Default:
See
Selection:
Blank or E
#34 Default Text [COMMAND][5][7]
Temporarily display the armed state of the area
using control panel default text, A# AREA # IS ON,
A# NOT READY, A# AREA # IS OFF, and A#
ACCOUNT IS ON.

L## Change Skeds

Program Record Sheet
Default:
See
Selection:
Blank or E
#35 Change Skeds [COMMAND][5][2]
Change skeds that can be edited.
Skeds can be restricted from being edited
by programming S## Time Edit? to No.
Custom Functions

L## C Function 128 [through 143]

Program Record Sheet
Default:
See
Selection:
Blank or E
128 to 143 Enable Custom Function 128 through
143 (MENU FUNCTION only)
Execute the desired Custom Function.
Bosch Security Systems | 10/03 | 47775E
, or two Zonex devices
Report Levels

L## Force Arm

Program Record Sheet
Default:
See
Selection:
Blank or E
Allows a user with this authority level to Force Arm.

L## Area O/C

Default:
See
Program Record Sheet
Selection:
Blank or E
Generate Opening and Closing Reports if the area
where this authority level is assigned sends Opening
and Closing Reports.

L## Restricted O/C

Program Record Sheet
Default:
See
Selection:
Blank or E
Initiate an Opening Report if a bell is ringing or a
Closing Report when force/bypass arming. The area
where this authority level is assigned must be
programmed for restricted openings and closings
(see the
A# Restrictd O/C
Open/Close Options)

.L## Perimeter O/C

Default:
See
Program Record Sheet
Selection:
Blank or E
Report Perimeter Opening and Closing Reports if
the area where this authority level is assigned sends
Perimeter Opening and Closing Reports.

L## Send Duress

Program Record Sheet
Default:
See
Selection:
Blank or E
Send a Duress Report if the area where this
authority level is assigned sends duress. (See the
Duress Enable
prompt in Section 2.9 Area
Parameters).

L## Passcode Arm

Program Record Sheet
Default:
See
Selection:
Blank or E
Arm an area by entering a passcode and pressing
[ENTER].