L## Chg Display; L## Chg Time/Date; L## Chg Passcode; L## Add User - Bosch D9412G Program Entry Manual

Table of Contents
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN

L## Chg Display

Program Record Sheet
Default:
See
Selection:
Blank or E
#15 Change Display [COMMAND][4][9]
Change the display (bright display, dim display, and
time display) in the area where this command center
is assigned.

L## Chg Time/Date

Default:
See
Program Record Sheet
Selection:
Blank or E
#16 Change Time and Date [COMMAND][4][5]
Change the date and time for the control panel in
this area.

L## Chg Passcode

Program Record Sheet
Default:
See
Selection:
Blank or E
#17 Change Passcodes [COMMAND][5][5]
Change a user passcode.

L## Add User

Program Record Sheet
Default:
See
Selection:
Blank or E
#18 Add User [COMMAND][5][6]
Add/change users, add/change authority levels,
add/change tokens/cards.
9210 NOT READY appears if a door
controller is not assigned (see CC#
Assign Door in Section 2.10.1 Cmd Cntr
(Command Center) Assignment) to the
command center used to add/change
tokens/cards.

L## Del User

Default:
See
Program Record Sheet
Selection:
Blank or E
#19 Delete User [COMMAND][5][3]
Delete users.
Bosch Security Systems | 10/03 | 47775E
0101
Although an individual user (001 through
0101
249) can be deleted separately, take
0101
caution. User passcode, token/cards
cannot be deleted individually within a
group (for example, User 001 has three
additional sub-users that use the same
authority levels for that group). When
dealing with an individual user, change
that user's token/passcode so other
users in the group do not need to be re-
added.

L## Extend Close

Default:
See
Program Record Sheet
Selection:
Blank or E
#20 Extend Close [COMMAND][5][1]
Change the closing time in the area where the
function is entered.

L## View Log

Program Record Sheet
Default:
See
Selection:
Blank or E
#21 View Log (MENU FUNCTION only)
View all panel-wide events in the control panel's
memory log.

L## Print Log

Program Record Sheet
Default:
See
Selection:
Blank or E
#22 Print Event Log (MENU FUNCTION only)
Print all panel-wide events from the log to the
printer in the area where the user is executing this
function.
This item can also be accessed using the
Service Menu ([9][9][ENT]).

L## User Cmd 7

Default:
See
Program Record Sheet
Selection:
Blank or E
#23 User COMMAND 7 [COMMAND][7]
Can be used in Function Menu. Generate the alarm
programmed at COMMAND 7 in the RADXPNTS
Handler.