5.3 Combining units and options

5.3.1 Possible options for the outdoor unit

5.3.2 Possible options for the indoor unit

EPGA11~16DAV3(7) + EAVH/X16S18+23DA6V(7)+9W(7)
Daikin Altherma 3 H F
4P556070-1A – 2021.09
Model identification
Example: E AV H 16 S 23 DA 6V G
Code
E
European model
AV
Floor-standing hydro-split unit with integrated tank
H
H=Heating only
X=Heating/cooling
16
Capacity class
S
Integrated tank material: Stainless steel
23
Integrated tank volume
DA
Model series
6V
Backup heater model
G
G=Grey model
[—]=White model
INFORMATION
Certain options might NOT be available in your country.
Bottom plate heater (EKBPH140L7)
Prevents freeze-up of the bottom plate.
Recommended in areas with low ambient temperature and high humidity.
For installation instructions, see the installation manual of the bottom plate heater.
User interface used as room thermostat (BRC1HHDA)
The user interface used as room thermostat can only be used in combination
with the user interface connected to the indoor unit.
The user interface used as room thermostat needs to be installed in the room
that you want to control.
For installation instructions, see the installation and operation manual of the user
interface used as room thermostat.
Room thermostat (EKRTWA, EKRTR1)
You can connect an optional room thermostat to the indoor unit. This thermostat
can either be wired (EKRTWA) or wireless (EKRTR1).
For installation instructions, see the installation manual of the room thermostat
and addendum book for optional equipment.