7
|
Unit installation
7.2.2 To open the outdoor unit
7.2.3 To remove the transportation stay
7.2.4 To close the outdoor unit
Installer reference guide
54
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
1
1
2
2
3×
1
1
NOTICE
If the unit is operated with the transportation stay attached, abnormal vibration or
noise may be generated.
The transportation stays (2×) protect the unit during transport. During installation
they must be removed.
a Transportation stays (2×)
1 Open the switch box cover. See
2 Remove the screws (4×) from the transportation stays, and dispose of them.
3 Remove the transportation stays (2×), and dispose of them.
NOTICE
When closing the outdoor unit cover, make sure that the tightening torque does NOT
exceed 4.1 N•m.
3 3
a
"7.2.2 To open the outdoor
EPRA14~18DAV3+W1 + ETVZ16S18+23EA6V+9W
4
unit" [
54].
Daikin Altherma 3 H HT F
4P644739-1 – 2021.02