Settings Mode - Electrolux SkyLine ChillS 202 User Manual

Lengthwise blast chillers/freezers
Table of Contents
2. Select the required cycle from the list shown:
HYGIENE
Manual Defrosting
Soft Drying
Strong Drying
Germicidal Cycle
Manual Defrosting
The appliance has an automatic defrost but it is possible to
select a manual defrost based on need.
Soft Drying
This function allows to perform a light cavity drying from
condensation.
Strong Drying
This function allows to perform an intense cavity drying from
condensation.
Germicidal Cycle
Available as option or only on specific models combined with
special accessory.
It allows to sanitise the surfaces and the air inside the
appliance compartment. It can also be used for kitchen
utensils such as: knives, carving forks, etc.
If the internal temperature is less than +15℃ the cycle will not
start.
Do not use this function if there is food in the compartment.
It is advisable to do a germicidal cycle at the start of the day
before using the appliance, and another at the end of the day,
after cleaning the compartment.
NOTE!
To maintain a maximum efficiency of the Germi-
cidal Cycle, it is advisable to replace the UV-C
lamp every 10 years.
The appliance has a safety device that switches off the lamps
when the door is opened.
This safety feature is provided because exposure to UV-C
radiation emitted by the lamps is harmful and can damage
eyes.
3. Open the door;
4. Open the drain plug;
If a Manual Defrosting or a Soft/Strong drying is selected,
keep the door opened with door stopper until the cycle ends.
34
00:00 h:m
00:00 h:m
00:00 h:m
00:00 h:m
5. Touch the button
to start the cycle;
At the start of the cycle, if the door is closed, a popup
window opens showing the message to open the door.
HYGIENE
7. When the cycle is finished a pop window appears showing
the following message:
HYGIENE
Electric consumption in kWh
Time consumption in hours : minutes : seconds
8. Close the drain plug immediately after the cleaning.
E.12 Settings mode
"Settings" mode allows to change some usage parameters of the
appliance.
1. Open the upper drawer and select Settings;
MAN UAL
Manual
1
-
Skyhub
?
Help
2. The display shows the main menu with ALL SETTINGS;
SETTING
a
Settings
Language
Date
18
Time
Measurement units
Sounds
Display
b
Touch screen calibration
Touch screen test
Food Safety
Norms
User Password
Open the door
Soft drying
done!
5.7 kWh
00:35:00
USER
Automatic
Prog rams
Chill
c
20
°
Hygiene
Settings
Agenda
USB
SkyDuo
Transfer
h:m
SETTING
Settings
Accessories
Manual
Automatic
Programs
MultiTimer
SkyHub
Hygiene
Identity Card
ID
Startup page
Service maintenance
Table of Contents
loading

Table of Contents