Environmental; Quality Assurance Program; Nuclear Cleaning; Hydrostatic Testing - Emerson Rosemount 3051N Reference Manual

Smart pressure transmitter for nuclear service
Hide thumbs Also See for Rosemount 3051N:
Table of Contents
Rosemount 3051N

Environmental

Quality Assurance
Program

Nuclear Cleaning

Hydrostatic Testing

5-2
Performance to normal operating limits as described in the "Performance
Specifications" and "Functional Specifications" sections of this manual.
In accordance with 10CFR50 Appendix B, ISO 9001:2000
To <1 ppm chloride content
Model
Range Code
3051ND
3051NG
(3)
3051NA
(1) Process O-ring Code A (glass-filled TFE).
(2) Maximum Working Pressure equals upper range limit (URL).
(3) Hydrostatic testing not performed on Rosemount 3051NA Range Code 0.
00809-0100-4808, Rev CA
Hydrostatic Test Pressure
0
750 psi
1
2000 psi
2–5
4200 psi
2–5
150% of maximum working pressure
1–4
Reference Manual
June 2008
(1)