Voltage Supply; Degree Of Protection And Weight; Standards; Standards Used - Bosch rexroth RegisterControl ATEX MLC 14VRS Operating Instructions Manual

Table of Contents
12/39

Standards

7.2 Voltage supply

The voltage for the PY-MSS01.1-T1 mark stream sensor is supplied via "X1S Pow-
er".
Supply voltage
Nominal current
Power consumption

7.3 Degree of protection and weight

Degree of protection
Weight (without packaging)
8 Standards

8.1 Standards used

The PY-MSS01.1-T1 mark stream sensor complies with the DIN EN standards lis-
ted in the following:
Standard
EN 61326-1
(directive 2014/30/EU)
DIN EN 60079-0
(directive 2014/34/EU)
DIN EN 60079-28
(directive 2014/34/EU)
Tab. 8-1: Safety standards
Bosch Rexroth AG R911341913_Edition 05
24 V DC (19 V...30 V DC)
Typ. 240 mA (at a nominal current of 24 V)
Max. 5.8 W
IP 54
Ca. 300 g
Electrical equipment for measurement, control and laboratory use –
EMC requirements – Part 1: General requirements
Edition 2013
Explosive atmospheres - Part 0
Equipment – General requirements
Explosive atmospheres - Part 28
Protection of equipment and transmission systems using optical radia-
tion
MLC 14VRS RegisterControl ATEX