1 Specifications Model No. MC-CG677K-S647 Power source AC230-240V~50Hz Input power (MAX) 1400W Input power (Nominal) 1100-1200W Power control Extension wand Metal telescopic Turbin nozzle Dimensions (WxLxH)mm 280x430x260 Net weight 5.1kg Cleaning tools Crevice nozzle / Dusting brush...
3 Troubleshooting Guide CONDITION CHECKPOINT METHOD OF INSPECTION CAUSE / REMEDY When dust is vacuumed off, the Air inlet Check whether or not dust or for- Wipe the dust sensor with a dry dust sensor indicator lamp doesn’t eign substances adhere to the dust soft cloth.
4 Disassembly and Assembly Instructions Important notice: Before replacing any components, make sure to turn OFF the vacuum cleaner. Remove the power plug from the outlet. 4.1. Dust box cover assembly 3. Remove the connectors from the lead wire AU and P.C.B. removal 1.
4.2. Separate the upper and lower 3. Lift the upper body U to separate it from the lower body U. body units 1. Remove the five screws fixing the upper body U and lower body U. 4.3. Printed circuit board assembly (P.C.B Ass’y) removal 1.
Page 8
4. Remove the P.C.B. Ass'y from the P.C.B. holder. 6. Remove the Control and Lead wiire BU. * When removing the P.C.B Ass’y, widen the frame of the P.C.B holder, and then remove the P.C.B from the hook of the P.C.B holder. Note: When removing the P.C.B.
4.4. Motor removal * Note: When the thermal protector has been replaced, make sure to paste the tape (gasket V) back 1. Lift the motor section from the lower body U. on the terminals. 4.5. Replacement of the indicator ornamental plate unit 1.
3. Turn it over to remove the indicator ornamental plate unit. 3. Remove the P.C.B. KU. 4. Remove the air inlet guide U and then remove the lead 4.6. Replacement of the P.C.B. DU, wire AU from the P.C.B. DU. P.C.B.
6. Similarly, remove the LED lamp printed circuit board from * For easy removal, pull out the cord slightly, and then lift the cord reel. the Air inlet guide U. 4.8. Rail base U replacement 4.7. Cord reel partition unit 1.
4.9. Spring-loaded cord reel 4.10.2. Separation of the floor nozzle upper U from the floor nozzle pre-winding lower U 1. The cord reel partition U has a spring that pre-winds the 1. Remove the four screws fixing the floor nozzle lower U. cord reel.
Page 13
4.10.4. Removal of the floor nozzle brush CU.DU.EU.FU 1. Turn the floor nozzle lower unit over. Insert the tip of a flat-blade screwdriver into the ditch in the brush installa- tion part, then remove the brush.(Fig.32)
6.4. PARTS LIST (BODY UNIT) Safety Ref.No Service Parts No. Part Name & Description Q'TY Remarks AMV93K-4K0KP DUST COVER ASS'Y AMV94M-4K0SP INDICATOR PLATE UNIT Silver AMV66J-4K00P AMV64H-4K00P SUCTION INLET PACKING AMV67V-4K00P LEAD WIRE A UNIT AMV87V-4K00E PRINTED CIRCUIT BOARD DU AMV80J-4K0KP AIR INLET GUIDE UNIT AMV66H-4K00P...
6.6. PACKING LIST Safety Ref.No Service Parts No. Part Name & Description Q'TY Remarks AMV61Z-4K0SS CARTON BOX AMV98Z-4K00R CUSHION U AMV90Z-4K00R PARTITION BOARD UNIT AMV69Z-4K00R CUSHION A AMC69Z-YD00P CUSHION A AMV75Z-4K00R CUSHION PLATE AMV62Z-4K00R CUSHION PLATE AMC10Z-YD00P BODY BAG AMV01Z-4K00S OPERATING INSTRUCTIONS...