Quick Links

TABLE OF CONTENTS

1 Specifications ----------------------------------------------------- 2
3 Troubleshooting Guide ----------------------------------------- 5
4.1. Remove the Dust cover assy. -------------------------- 6
and the Pedal cover. -------------------------------------- 6
unit.------------------------------------------------------------ 7
4.5. Remove the P.C.B. A Unit. ------------------------------ 9
4.6. Remove the Motor. ---------------------------------------10
5 Wiring Connection Diagram ---------------------------------12
6 Exploded View and Replacement Parts List -----------13
6.1. EXPLODED VIEW (ATTACHMENTS) --------------13
6.2. PARTS LIST (ATTACHMENTS) ----------------------14
6.3. EXPLODED VIEW (BODY UNIT) --------------------15
6.4. PARTS LIST (BODY UNIT) ----------------------------16
Model No.
Product Color :Royal Silver
Destination
PAGE
6.5. PACKING INSTRUCTIONS --------------------------- 18
6.6. PACKING LIST ------------------------------------------- 19
© 2008 Matsushita Electric Industrial Co.,Ltd. All
rights reserved. Unauthorized copying and distribu-
tion is a violation of law.
Order Number VCB0808014CE
Vacuum Cleaner
MC-CG881C-SC79
MC-CG881K-SP47
:Europe
PAGE
Table of Contents
loading

Summary of Contents for Panasonic MC-CG881C-SC79

  • Page 1: Table Of Contents

    Order Number VCB0808014CE Vacuum Cleaner MC-CG881C-SC79 Model No. MC-CG881K-SP47 Product Color :Royal Silver Destination :Europe TABLE OF CONTENTS PAGE PAGE 1 Specifications ----------------------------------------------------- 2 6.5. PACKING INSTRUCTIONS --------------------------- 18 2 Location of Controls and Components ------------------- 3 6.6. PACKING LIST ------------------------------------------- 19...
  • Page 2: Specifications

    1 Specifications Model No. MC-CG881C-SC79 MC-CG881K-SP47 Power source AC230V~50Hz AC230V~240V~50Hz Input power (MAX) 1600W Input power (IEC) 1300W 1250W~1300W Power control Extension wand Metel telescopic Nozzle assy Dimensions (WxLxH)mm 312×489×243 Cord length 6.5m Net weight 6.5kg Cleaning tools Crevice nozzle / Upholstery nozzle / Dusting brush...
  • Page 3: Location Of Controls And Components

    2 Location of Controls and Components...
  • Page 5: Troubleshooting Guide

    3 Troubleshooting Guide CONDITION PARTS TO BE CHECKED CHECK METHOD REMEDY The motor does not rotate. Power cord Check if the power cord is broken. If the cord is broken, replace the Inspect the cord in the cord reel cord reel assy. assy for continuity.
  • Page 6: Disassembly And Assembly Instructions

    4 Disassembly and Assembly Instructions Precautions: Make sure to power off the vacuum cleaner before replacing the parts. Disconnect the plug from the outlet. Caution: (1) When disassembling, check the component fitting state and wirings. After repairing, always restore them to the origi- nal state.
  • Page 7: Remove The Upper Body Unit And Lower Body Unit

    4.3. Remove the Upper body unit 3. Remove the Swivel cap. and Lower body unit. 1. Remove the screw from the Handle of the Lower body. 4. Remove the two screws each from the Switch cover and Pedal cover. 2. Remove the 2 screws holding the Lower body. 5.
  • Page 8: Remove The Cord Reel Partition Unit

    4.4. Remove the Cord reel partition 4. Remove the Upper body. unit. 1. Remove the Cord reel partition unit from the Lower body. 2. Disconnect the terminals of the two Lead wires. Note: Pull out the terminals while pressing the termi- nal lock to release it.
  • Page 9: Remove The P.c.b. A Unit

    4. Remove the screw at the center of the Body partition. 2. Remove the Body lining upper. 5. Remove the Cord reel assy from the Body partition. 3. Remove the Control connected to the P.C.B A Unit. 4.5. Remove the P.C.B. A Unit. 1.
  • Page 10: Remove The Motor

    4.6. Remove the Motor. Lead wire connection of the P.C.B A unit. 1. Remove the Motor case lining and the Motor case rubber. Note: Attach gasket F so that the lead wire will be 5. Remove the P.C.B A Unit from the Motor cover. sandwiched by the slit of gasket F.
  • Page 11 4. Remove the Motor cover and the Motor case. 6. Remove the Motor case plate. 7. Remove the Motor support. 8. Remove the Motor support rubber (front). 9. Disconnect the two Lead wires of the Motor. 5. Remove the thermal protector. Note: When assembling the motor, set the motor in the motor case with the thermal protector located on the...

This manual is also suitable for:

Mc-cg881k-sp47

Table of Contents