Configuration; About Standby Electricity Saving Function; To Turn On Standby Electricity Saving Function - Daikin 3AMXM52N2V1B9 Installer's Reference Manual

R32 split series
Hide thumbs Also See for 3AMXM52N2V1B9:
Table of Contents

11 Configuration

In this chapter

11.1 About standby electricity saving function

11.1.1 To turn ON standby electricity saving function

3AMXF-A9, 3AMXF-A9, 3AMXM-N9
R32 Split series
4P600463-1F - 2022.05
11.1
About standby electricity saving function..............................................................................................................................
11.1.1
To turn ON standby electricity saving function .....................................................................................................
11.2
About priority room function .................................................................................................................................................
11.2.1
To set the priority room function ..........................................................................................................................
11.3
About night quiet mode .........................................................................................................................................................
11.3.1
To turn ON the night quiet mode ..........................................................................................................................
11.4
About heat mode lock ............................................................................................................................................................
11.4.1
To turn ON heat mode lock....................................................................................................................................
11.5
About cool mode lock.............................................................................................................................................................
11.5.1
To turn ON cool mode lock ....................................................................................................................................
The standby electricity saving function:
turns OFF the power supply to the outdoor unit and,
turns ON the standby electricity saving mode on the indoor unit.
The standby electricity saving function works with following units:
3AMXM52
If another indoor unit is used, the connector for standby electric saving MUST be
plugged in.
The standby electricity saving function is turned OFF before shipping.
Prerequisite: The main power supply MUST be turned OFF.
1 Remove the service cover.
2 Disconnect the selective standby electricity saving connector.
3 Turn ON the main power supply.
11
|