Precautions For Wiring; Wiring To Power Connector And Terminal Block - Panasonic MINAS A6N Manual

Ac servo driver
Hide thumbs Also See for MINAS A6N:
Table of Contents

8-3 Precautions for wiring

8-3-1 Wiring to power connector and terminal block

Size A, B 100 V / 200 V
MCCB
Power supply
(3-phase)
When using with single
*
phase power supply, be sure
to connect between L1 and
L3 terminals.
■ Connection of regenerative resistor
Short wire
Size
(accessory)
A
None
B
* The circuit connected to terminal X1 – X7 are secondary circuits. (See [ 5. Appearance and name of each part ])
Insulation is needed against the primary side power supply (power supply of the motor brake).
Please do not connect them with the same power supply.
* For details, refer to 7-1 Power connector XA, XB, XC, XD and terminal block.
R6.0
Thermostat
external
( See above)
regenerative resistor
When using the amplifier with VCM,
connect the U and W terminals
Isolated power supply
DC12~24 V
(±5 %)
Internal
regenerative
In case of using the external
resistor
Between P and B:
None
Connect the external
regenerative resistor.
Built- in Thermostat of an external regenerative resistor
( The wire color of optional accessories is light yellow)
ON
OFF
L
MC
Red
White
Black
Green or
Green/yellow
M
ALM
+
-
Connection of connector XB
regenerative resistor
Motion Control Business Unit, Panasonic Corporation
No. SX-DSV03224-50-
MC
ALM
Coil surge absorber
XA
L1
Main power
L2
supply
L3
L1C
Control power
L2C
supply
XB
Unlike the CD frame,
P
do not connect
N
a short wire to XB
B
in case of Size A and B
U
Motor output
V
W
X4
ALM+
ALM-
In case of not using the external
regenerative resistor
Between P and B:
Keep open
Table of Contents
loading

Table of Contents