Electrolux ESV09CRS-B2 Installation Manual
Hide thumbs Also See for ESV09CRS-B2:

Quick Links

ESV09CRS-B2
ESV12CRS-B2
ESV09CRR-C6
ESV09CRR-C7
EN AIR CONDITIONER
ESM09CRR-B3
ESM12CRR-B3
ESM18CRR-B3
INSTALLATION MANUAL
2
loading

Summary of Contents for Electrolux ESV09CRS-B2

  • Page 1 ESV09CRS-B2 ESM09CRR-B3 ESV12CRS-B2 ESM12CRR-B3 ESM18CRR-B3 ESV09CRR-C6 ESV09CRR-C7 EN AIR CONDITIONER INSTALLATION MANUAL...
  • Page 2: Table Of Contents

    5. APPENDIX ......................21 WE’RE THINKING OF YOU Thank you for purchasing an Electrolux appliance. You’ve chosen a product that brings with it decades of professional experience and innovation. Ingenious and stylish, it has been designed with you in mind. So whenever you use it, you can be safe in the knowledge that you’ll get great results every time.
  • Page 3: Safety Instructions

    ENGLISH SAFETY INSTRUCTIONS Before the installation and use of the • Installation work must be performed appliance, carefully read the supplied in accordance with the national wiring instructions. The manufacturer is not standards and the electricity suppliers responsible if an incorrect installation and service rules by authorised personnel use causes injuries and damages.
  • Page 4 4 www.electrolux.com • For safety, be sure to turn off the • Do not step on the top of the outdoor circuit breaker before performing any unit or place heavy things on it. It may maintenance or cleaning or when the cause damage or injury.
  • Page 5: Before Installation

    ENGLISH 2. BEFORE INSTALLATION 2.1 Tools needs for installation 1. Level gauge 10. Gas-leak detector 2. Screw driver 11. Vacuum pump 3. Electric drill 12. Gauge manifold 4. Hole core drill 13. Pipe expander 5. Flaring tool set 14. Multimeter 6.
  • Page 6 6 www.electrolux.com 6 www.electrolux.com 2.3 Product Description Space to the ceiling Space to the wall ≥15cm Space to the wall ≥15cm Air outlet side Space to obstruction Air inlet side Space to the wall ≥30cm ≥50cm Space to the wall...
  • Page 7 ENGLISH 2.4 Installation site Outdoor unit • Maintain the minimum installation • Do not install the unit in areas with: distances specified in this document. – strong heat sources; • Do not block the air inlet or the air outlet. –...
  • Page 8: Product Installation

    8 www.electrolux.com 3. PRODUCT INSTALLATION 3.1 Indoor unit installation 3.1.3 Connective pipe 3.1.1 Installing the Wall Mounting 1. For the left-hand and right-hand piping, remove the pipe cover from the side Plate panel. The pipe cover can be kept as it may be used when relocating the air 1.
  • Page 9 ENGLISH 3.1.6 Piping and wrapping 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, 1. Bundle the tubing, connecting cable, do not let the drain hose slack. and drain hose with tape securely and evenly as shown in the Fig.3.1.6.
  • Page 10 10 www.electrolux.com 3.2.2 Condensate drainage of without obstacles. outdoor unit (only for heat pump 3. Install the unit at the site where it is exposed to as little wind as possible, model) especially not in areas where it is frequently windy.
  • Page 11 ENGLISH 3.3.1 Flaring work 3. Put nut on • Remove flare nuts attached to indoor Main cause for refrigerant leakage is due and outdoor unit, then put them on to defect in the flaring work. pipe/tube after completed burr removal. (It is not possible to put them on after Carry out correct flaring work using the flaring work.)
  • Page 12 12 www.electrolux.com 3.4 Piping Connection Fig.3.4.1-3 Cable Ties Insulation 3.4.1 Indoor Unit Material 1. Connecting the indoor unit tubing to the connection piping: • Align the centers of the pipes and sufficiently tighten the flare nut with your • Ensure to isolate separately the suction hands first.
  • Page 13 ENGLISH 3. Hang the indoor unit: Fig.3.4.2-1 • Remove the spacer. • Hook the indoor unit onto the upper portion of the mounting plate (Engage the hooks of the mounting plate into the openings at the rear top of the indoor unit).
  • Page 14 14 www.electrolux.com 3.4.4 Checking the Drainage • Wrap the piping, drain hose and connecting cable from the down to up. 1. Open and lift the indoor unit front panel. • Secure the wrapped piping along the exterior wall using saddle or equivalent.
  • Page 15 ENGLISH Fig.3.4.4-3 before the customer fixes the problem. 6. Be sure the power supply matches the Downward air conditioner. slope 7. Ensure the live wire, neutral wire and earth wire in the power socket are properly connected. 8. Inadequate or incorrect electrical connections may cause electric shock, fire or some electrical parts to malfunction.
  • Page 16 16 www.electrolux.com 2. Route the power connection cable • Do not connect two power cables and signal control wire (for heat pump together to supply power to the air model only) from back of the indoor unit conditioner. and pull it toward the front through the •...
  • Page 17 ENGLISH 3.6 Air Purging and Leakage Fig.3.5.3-2 Test Air and moisture in the refrigeration system have undesirable effects as indicated below: • Pressure in the system rises. • Operating current rises. • Cooling or heating (only for models with heating function) efficiency drops. Magnetic ring •...
  • Page 18 18 www.electrolux.com Fig.3.6.1 Outdoor unit Outdoor unit Oil trap Indoor unit Indoor unit Piping length under 4m Piping length 4m or more (A): Maximum Piping Length (B): Maximum Piping Height needed when outdoor unit installed at a NOTE: lower place than indoor unit).
  • Page 19: Test And Running

    ENGLISH 6. Turn the stem of the packed valve B NOTE: about 45 counter clockwise for 6~7 • The schrader valve is inside the seconds after the gas comes out, then charging port. tighten the flare nut again. Make sure 2.
  • Page 20 20 www.electrolux.com 4.2 Electrical Safety Check 4.4 Pump Down Perform the electric safety check after When relocating or disposing of the air completing installation: conditioner, pump down the system following the procedure as below so 1. Earthing work that no refrigerant is released into the •...
  • Page 21: Appendix

    ENGLISH 5. APPENDIX Appendix(1) Outdoor Unit Indoor Unit Mounting Plate Dimension (mm) Dimension (mm) Type 660*500*240 750*285*200 665*420*280 750*285*200 730*545*285 750*285*200 800*545*315 750*285*200 730*545*285 837*296*205 800*545*315 837*296*205 800*545*315 952*310*227 825*655*310 952*310*227 900*700*350 1082*330*233 533.7mm 390mm Type A 510mm Type B 510mm Type C...
  • Page 22 22 www.electrolux.com Appendix(2) Minimum Cross-Sectional Area Cable Types: of Power and Power Cables Indoor power cable: H05VV-F (if applicable) Rated Current Nominal Cross-Sectional of Appliance (A) Area (mm²) Power cable: H07RN-F or H05RN-F >3 and ≤ 6 0.75 The size of the power supply >6 and ≤...
  • Page 23 Models Length (m) Height (m) Refrigerant Diameter (mm) Diameter (mm) Length (m) (g/m) ESV09CRS-B2 ESV12CRS-B2 Ø9.52 (3/8") Ø6.35 (1/4") ESV09CRR-C6 ESV09CRR-C7 The Minimum length pipe is 3m Additional refrigerant required for pipe length greater than standard 7.5m installation can be calculated using the following equation: M = (F –...
  • Page 24 91030a...