5.5.6 Settings for Ethernet and RS485 communication

Click '
' to shift window of 'Ethernet Setup' and 'RS485 Setup'.
[Ethernet Setup]
1
Item
1
IP address
2
MEWTOCOL-COM
3
MODBUS-TCP
48
Select the setting method for the IP address.
When you select "Use the following IP address", set the IP
address, subnet mask and default gateway manually.
< Range >
Setting IP address: Obtain an IP address automatically or Use
the following IP address
IP address: 001. 000. 000. 000 to 255. 255. 255. 255
Subnet mask: 128. 000. 000. 000 to 255. 255. 255. 255
Default gateway: 001. 000. 000. 000 to 255. 255. 255.255
Set protocol and port number.
< List & Range >
Protocol: TCP, UDP (initial: TCP)
Port number: 1024 to 65535 (initial: 9094)
Set protocol and port number.
< List & Range >
Protocol: TCP, UDP (initial: TCP)
Port number: 502, 1024 to 65535 (initial: 502)
Description
(initial: 192.168.1.5)
(initial: 255.255.255.0)
(initial: 192.168.1.1)
KW2M-A/X User's Manual