  • Page 1 INSTRUCTIONS GE Industrial Systems GE Industrial Systems D20A6 expanded I/O for AV-300i Drives 12 Digital Inputs 8 Digital Outputs 2 Analog Inputs 2 Analog Outputs (V) 2 Analog Outputs (I)
  • Page 2 If further information is desired or if particular problems arise that are not covered sufficiently for the purchaser’s purpose, the matter should be referred to GE Industrial Systems, Salem, Virginia, USA. This document contains proprietary information of...
  • Page 3 SAFETY SYMBOL LEGEND / LÉGENDE DES SIGNES DE SÉCURITÉ ARNING Commands attention to an operating procedure, practice, condition, or statement which, if not strictly observed, could result in personal injury or death. Attire l’attention sur les modes d’utilisation et les procédés et conditions d’exploitation qui, en cas d’inobservation, pourraient entraîner des blessures corporelles ou la mort.
  • Page 5: Table Of Contents

    D20A6 Table of Contents SAFETY SYMBOL LEGEND / LÉGENDE DES SIGNES DE SÉCURITÉ ................3 Chapter 0 - SAFETY PRECAUTIONS / PRECAUTIONS DE SECURITÉ ................6 Chapter 1 - INTRODUCTION ............. 12 Chapter 2 - MOUNTING ............14 Chapter 3 - TERMINAL BOARD POINTS ........15 3.1 DIGITAL INPUTS TERMINAL BOARD POINTS ........
  • Page 6: Sécurité

    GEI-100427A Chapter 0 - SAFETY PRECAUTIONS / PRECAUTIONS DE SECURITÉ The terms “Inverter”, “Controller” and “Drive” are sometimes used interchangably throughout the indus- try. We will use the term “Drive” in this document Les mots “Inverter”, “Controller” et “Drive” sont interchangeables dans le domaine industriel.
  • Page 7 D20A6 89/392/EEC concernant le secteur de l’industrie. Les systèmes provoquent des mouvements mécaniques. L’utilisateur est responsable de la sécurité concernant les mouvements mécaniques. Les dispositifs de sécurité prévues par l’usine et les limitations operationelles ne doivent être dépassés ou modifiés.
  • Page 8 GEI-100427A Drives should be installed away from hazardous areas, even if used with motors suitable for use in these locations. L’utilisation des drives dans des zônes à risques (présence de vapeurs ou de poussières inflammables), peut provoquer des incendies ou des explosions. Les drives doivent être installés loin des zônes dangeureuses, et équipés de moteurs appropriés.
  • Page 9 D20A6 ! / P AUTION RECAUTION Do not connect power supply voltage that exceeds the standard specification voltage fluctuation permissible. If excessive voltage is applied to the Drive, damage to the internal components will result. Do not operate the Drive without the ground wire connected. The motor chassis should be grounded to earth through a ground lead separate from all other equipment ground leads to prevent noise coupling.
  • Page 10 GEI-100427A A capacitative load (e.g. Var compensation capacitors) should not be con- nected to the output of the frequency inverter (terminals U2, V2, W2). The electrical commissioning should only be carried out by qualified per- sonnel, who are also responsible for the provision of a suitable ground connection and a protected power supply feeder in accordance with the local and national regulations.
  • Page 11 D20A6 d’enlever des matériaux isolants ou des capots. Protéger l’appareil contre des effets extérieurs non permis (température, humidité, chocs etc.). Aucune tension ne doit être appliquée sur la sortie du convertisseur (bornes U2, V2 et W2). Il n’est pas permis de raccorder la sortie de plusieurs convertisseurs en parallèle, ni d’effectuer une connexion directe...
  • Page 12: Chapter 1 - Introduction

    GEI-100427A Chapter 1 - INTRODUCTION The D20A6 card is an AV-300i drive option used to add digital inputs, digital outputs, analog inputs, analog outputs to the drive. It is possible to use only one I/O expansion card per Drive. This option card features:...
  • Page 13 D20A6 Back side —————— I/O Expansion card ——————...
  • Page 14: Chapter 2 - Mounting

    The D20A6 card is supplied with standoffs and the cable for connection between regulation and expansion card . Switch the drive off. Fasten the D20A6 card to the drive regulation board by means of screws (B) and standoffs (A). The D20A6 card is connected to the regulator card through the XH connector using the supplied connector.
  • Page 15: Chapter 3 - Terminal Board Points

    D20A6 Chapter 3 - TERMINAL BOARD POINTS 3.1 DIGITAL INPUTS TERMINAL BOARD POINTS Connectors XDI0 and XDI1 have different ground connection. DIGITAL INPUTS Connector XDI0 Terminal Function (Fw 1.X ) Digital input 5 Digital input 6 Digital input 7 Digital input 8 GND Function (Fw 2.X )
  • Page 16: Analog Inputs Terminal Board Points

    GEI-100427A 3.3 ANALOG INPUTS TERMINAL BOARD POINTS Differential analog inputs are available. ANALOG INPUTS Connector Terminal Function (Fw 1.X ) n.a. n.a. n.a. n.a. An inp 1X + An inp 1X - An inp 2X + An inp 2X - Function (Fw 2.X ) n.a.
  • Page 17: Functional Overview

    D20A6 3.5 FUNCTIONAL OVERVIEW 0V (COM) Digital input 5 (DI0X) +24V (PWR) Digital output 3 Digital input (DO0X) (DI1X) Digital output 4 Digital input (DO1X) (DI2X) Digital output 5 (DO2X) Digital input (DI3X) Digital output 6 (DO3X) (DI4X) Digital output 7...
  • Page 18: Chapter 4 - Jumpers

    GEI-100427A Chapter 4 - JUMPERS Following table describes the expansion board jumpers. JUMPERS ON BOARD Default Name Description Adaption to the input signal of analog input 1 ON 0…20mA / 4…20mA OFF 0…10V / -10V…-10V Adaption to the input signal of analog input 2 ON 0…20mA / 4…20mA OFF 0…10V / -10V…-10V expDA50...
  • Page 19: Chapter 6 - Technical Data

    D20A6 Chapter 6 - TECHNICAL DATA Dimensions and Weight 92.36 Dimensions _________________________________ 142.49mm [5.6 inches] x 92.36 mm [3.63 inches] Weight _____________________________________ 77 g [2.7 oz] —————— I/O Expansion card ——————...
  • Page 20: General Data

    GEI-100427A General Data I/O scan time ________________________________ 2ms Internal power supply from the drive _____________ +5VDC, ±18VDC The Drive TB can be used to supply 24VDC power. AV-300i 24VDC supply maximum output = 120 mA total including Encoder, LAN, EXP card and DGF. (or 350 mA without DGF) Digital Inputs Input type __________________________________ Voltage/Optocoupled Inputs no.
  • Page 21: Voltage Analog Outputs

    D20A6 Voltage Analog Outputs Output type _________________________________ Voltage Outputs no. _________________________________ 2 Max Output voltage __________________________ ±10V Output current ______________________________ 5mA max Bandwidth __________________________________ 265Hz Current Analog Outputs Output type _________________________________ Current Outputs no. _________________________________ 2 Max Output voltage __________________________ 0 up to 14V...
  • Page 22: Chapter 7 - Accessories

    GEI-100427A Chapter 7 - ACCESSORIES Terminals XDI0,XDI1, XDI2, XAI, XAQV, XAQI Type PHOENIX CONTACT 5 contacts MC1,5/5 ST3,81 1803604 or equivalent. Terminals XDQ __________________________ Type PHOENIX CONTACT 10 contacts MC 1,5/10 ST3,81 1803659 or equivalent. Chapter 8 - MAXIMUM WIRE SIZES Terminals on connector XDQ, XDI1, XDI2,XDI3, XAI,XAQV, XAQI 0.14 …...
  • Page 24 1S5G21 GEI-100427A 001109 SIEI...