Gemini slimline plastic light source range (17 pages)
Summary of Contents for UFO MicroLED 3000
Page 1
PRODUCT USER GUIDE MicroLED 3000 Light Source Rev: C1 PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE LIGHT SOURCE UNIT E357731...
Page 2
INTRODUCTION Thank you for purchasing this UFO light source/luminaire. To ensure that the light source is set up optimally and gives a long service life, please read this user guide before installing, operating or performing any maintenance on the unit.
Plug the mains plug into the electrical supply socket. Switch on power the led Indicator will illuminate and the light source will start up automatically. If no light is produced consult the TROUBLESHOOTING section NOTE: THESE LIGHT SOURCES ARE NOT MAINS DIMMABLE. UFO LIGHTING...
OPERATION MIC 3000 REMOTE CONTROLLER Description Details Comments Power 2 X AAA batteries Measured in free space, may Range 30 metres be attenuated by obstructions or other RF devices Approved for use in UK, Frequency 2.4GHz Europe and USA Batteries – With The LED Light Source powered up as described above, remove the rear cover on Remote Controller.
OPERATION REMOTE CONTROLLER OPERATION Matching Remote to Light Source– Remove the power plug from the rear of the Light Source, then replace and touch button 5 within 3 seconds, the Light Source will “blink” twice slowly indicating that the Remote Controller is matched to the Light Source. Unmatching Remote from Light Source- Remove the power plug from the rear of the Light Source, then replace and touch and hold button 5 within 3 seconds and the Light Source will “blink”...
Page 7
Brightness – brightness can be increased or reduced in any mode using buttons 6 & 7 Cycle Speed – speed of colour cycling in Modes 3 to 14 can be adjusted using buttons 5 & 8 UFO LIGHTING...
OPERATION REMOTE RANGE WALK TEST Once the Light Source is fully installed carry out a complete range walk test and record the range in the table below. This information is essential for maintenance purposes to determine if the range/sensitivity is reducing and also to record dead areas within the Remote Controller’s range due to RF obstructions and/or RF interference.
5. DMX OPERATION The MicroLED 3000 is programmed as a Master unit (See Mode designation label on rear of unit) and is capable of interlinking to and controlling MicroLED Slave Light Sources using a RJ45 cable linking the two. In this Master /Slave configuration the Slave Light Source will follow the Master Light Source.
MAINTENANCE MAINTENANCE LOG Date Maintenance Undertaken Note: A record of all maintenance MUST be kept in the table above, indicating what maintenance was undertaken and when. This MUST be dated for warranty purposes. 3000 MICROLED USER GUIDE...
DMX cable disconnected or faulty configuration, slave repair or replace light source works on standalone but Check master light source - refer to the relevant does not respondto Master light source not sending DMX signal user guide troubleshooting section DMX from master UFO LIGHTING...
TECHNICAL SPECIFICATION Port Connector Size Dual 30mm diameter Fibre Type Glass / PMMA Material/Finish Aluminium, silver anodised Dimensions (L x W x H) 140mm (5.5”) x 106mm (4.2”) x 68mm (2.7”) Weight 0.6kg Operating Environment Indoor use - IP20 Min Ambient Temp. -10°C Max Ambient Temp.