5.1

Induction generator fault indicator

Display of a fault message
− The "On" light comes on for approximately 0.6 seconds.
− This is followed by rapid flashing signals.
The flashes must be counted. The number of flashes indicates the fault code. The fault can be
determined from the table below.
Number of
flashes
--
1
2
3
4
5
6
7
8
10
Fault
Cause
No fault
No fault
No heat being gen­
Unsuitable pan material
erated
No coil current, hard­
ware overcurrent
Coil or power PCB
faulty
No heat being gen­
Unsuitable pan material
erated
High coil current, soft­
ware overcurrent
CPU or power board
faulty
The appliance
Temperature at heat
switches off.
sink too high.
Fan, rectifier, sensor or
CPU faulty.
The appliance
Hob temperature - over­
switches off.
heating
Sensor faulty.
The appliance
Line break on the rotary
switches off.
power switch
The appliance con­
Elevated internal tem­
tinues to operate at
perature
reduced power in
clocked operation.
The appliance
Sensor faulty.
switches off.
The appliance
Mains phase failure
switches off.
The appliance
No connection to the
switches off.
generator.
Action
Compare with different hob and cook­
ware. Notify an authorized customer
service agent if the problem occurs
again with a different pan.
Compare with different hob and cook­
ware. Notify an authorized customer
service agent if the problem occurs
again with a different pan.
Clean the air filter
Have the supply and exhaust air flow
in the generator compartment
checked by an authorized customer
service agent and have the fan
cleaned.
Have the components checked by an
authorized customer service.
Empty cookware
Cookware damaged by overheating
and no longer usable.
Contact an authorized customer ser­
vice agent.
Contact an authorized customer ser­
vice agent.
Ambient temperature too high.
Clean the air filter
Check circulation of supply and ex­
haust air in the generator compart­
ment.
Contact an authorized customer ser­
vice agent.
Check phases. Contact an authorized
customer service agent.
Contact an authorized customer ser­
vice agent.
en