HANYOUNG NUX TPR-3SL-EP Instruction Manual

Power regulator

Quick Links

(021)33985010-33985020
Power REGULATOR
TPR-3SL-EP
INSTRUCTION MANUAL
Thank you for purchasing HANYOUNG product.
Please check whether the product is the exactly same as you ordered.
Before using the product, please read this instruction manual carefully.
Please keep this manual where you can view at any time
Safety information
Before using the product, please read the safety information thoroughly and use it properly.Alerts declared in the manual
are classified to Danger, Warning and Caution by their criticality
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury
Danger
To prevent electric shock while it is running, put to earth with the fixed screw of the unit and do not touch the radiator
panel since it is very hot. Do not touch or contact the input/output terminals because they cause electric shock.
Warning
•Please install appropriate protective circuit on the outside if malfunction or an incorrect operation may be
a cause of leading to a serious accident.
•If you use the product with methods other than specified by the manufacturer, there may be bodily injuries
or property damages.
•Since this product is not designed as a safety device if it is used with systems, machines and equipment
that could lead to a risk of life or property damage, please implement safety devices and protections for
both lives and the applications and plan for preventing accidents.
•To prevent damage or failure of this product, please supply the rated power voltage.
•To prevent electric shock or equipment failure, please do not turn on the power until completing wiring.
•Never disassemble, modify, or repair the product. There is a possibility of malfunction, electric shock,
or a risk of fire.
•Please turn off the power when mounting / dismounting of the product. This is a cause of electric shock,
malfunction, or failure.
Caution
•Since the product operating environment influences the product performance and expected life span,
please avoid using in the following places.
· a place where humidity is high and air flow is inappropriate.
· a place where dust or impurity accumulates, ambient temperature is high and vibration level is high.
· a place where corrosive gas (such as harmful gas, ammonia, etc.) and flammable gas occur.
· a place where there is direct vibration and a large physical impact to the product.
· a place where there is water, oil, chemicals, steam, dust, salt, iron or others (Contamination class 1 or 2).
· a place where excessive amounts of inductive interference and electrostatic and magnetic noise occur.
· a place where heat accumulation occurs due to direct sunlight or radiant heat.
•Please do not wipe this product with organic solvents such as alcohol, benzene and others. (Please use mild detergent)
•Please make sure to inspect the product if exposed to water since there is a possibility of electric leakage or a risk of fire.
•Please connect the product and other units after turning off all the power of the product, instruments and units.
•Please make sure that the power control (TPR) is installed perpendicularly.
•Please install the product inside of the control panel and install an exhaust fan onto the top of the control panel.
•Pay attention to the edge of heat sink which is sharp.
•Please close the cover after installation in the place there is a cover.
•The external circuit connected with the product should be connected by an insulated circuit more than basic insulation.
Suffix code
Model
Code
TPR-3SL
 -
Slim type 3-phase power regulator
040
40 A
055
55 A
070
70 A
Rated current
090
90 A
130
130 A
160
160 A
L
100 - 240 V a.c.
Power supply voltage
H
100 - 440 V a.c.
Option
EP
Each phase control (3 device individual control)
※ The circuit power and fan power must be applied separately 100 - 240 V a.c.
※130 A, 160 A products are FAN power 24 V d.c. Voltage must be applied.
Specification
TPR-3SL
TPR-3SL
Low
040L-EP
055L-EP
Model
High TPR-3SL
TPR-3SL
040H-EP
055H-EP
Low
Power supply
voltage
High
Circuit input power
Power frequency
Rated current
40 A
55 A
Applying load
Current input
4 - 20 mA d.c. (Impedance : 100 Ω)
Control method
Phase control, Fixed Cycle control, Variable Cycle control, ON/OFF control
Movement type
Output voltage
More than 98 % of the power supply voltage (In case of maximum current input)
Cooling method
Display method
Insulation resistance
Min 100 MΩ (Base on 500 V d.c. mega)
Output control range
Dielectric strength
Line noise
Noise by noise simulator (2,500 V)
Ambient temperature
0 ~ 40 ℃ (Without Condensation)
Ambient Humidity
Storage temperature
Weight
4,324 g
www.AltonSegal.com
Information
TPR-3SL
TPR-3SL
TPR-3SL
070L-EP
090L-EP
130L-EP
TPR-3SL
TPR-3SL
TPR-3SL
070H-EP
090H-EP
130H-EP
100 - 240 V a.c.
100 - 440 V a.c.
100 - 240 V a.c. 18 W
50/60 Hz (Dual usage)
70 A
90 A
130 A
Resistive load
SOFT START, SOFT UP/DOWN
Forced cooling
Display by LED
0 ~ 100 %
3000 V a.c. 50/60 Hz for 1 min
30 ~ 85 % RH
-25 ~ 70 ℃
9,194 g
9,288 g
HANYOUNGNUX CO.,LTD
28, Gilpa-ro 71beon-gil, Nam-gu, Incheon, Korea
HEAD OFFICE
TEL : (82-32)876-4697
Connection diagram
█ Connection diagram of load terminal
· Inside of TPR, the fuse is installed in the R,S,T input power supply portion depending on the
specification of options
· When connecting terminals, please use crimp connectors and securely fasten them due to
the high current flow.
(Max space for solder less terminal connection is 40/55/70 A : 16 mm, 90/130 A : 26 mm)
· Only one channel can be used per temperature controller. (Serial connection disabled)
· Since the internal GND is not separated, use a module or temperature controller that has
separate analog inputs for each channel.
Connection diagram of signal and alarm terminal
• NO. 1, 2 : RS485 Communication connection port
• NO. 3, 4 : Channel 1 4 - 20 mA d.c. input
• NO. 5, 6 : Channel 2 4 - 20 mA d.c. input
• NO. 7, 8 : Channel 3 4 - 20 mA d.c. input
• NO. 9, 10 : Alarm1 caution
"caution" The alarm is not a serious problem, but it is an alarm that needs to be checked by
the user due to abnormal symptoms. At this time, the TPR output will go out to normal and
only the alarm will be output.
TPR-3SL
· Caution error : partial load disconnection, heat sink overheat (60 ℃), overcurrent,
160L-EP
power failure, fuse disconnection, FAN error
TPR-3SL
• NO. 11, 12 : Alarm2 warning
160H-EP
If a "Warning" alarm can cause damage to the product and the load, a warning will be
issued in the following emergency situations. At this time, the TPR will stop the output itself.
· Warning error : Heat sink overheat (80 ℃), SCR conduction (Short)
※ When the input power (100 - 240 V a.c.) is applied, the alarm relay opens and it is
shorted when an alarm occurs. ("B" contact Normal close) In case of using "A" contact
160 A
※ If an alarm condition occurs, an alarm is output after 3 seconds, and if the alarm
condition is released within 3 seconds, an alarm No output.
Connection diagram of input signal and power terminal
· Extra input power supply
(For circuit power and FAX operation power) :
100 - 240 V a.c. (13, 14)
Have to connect power to operate unit
(Even if do not need to use FAN).
1
telegram.me/altonsegal
telegram.me/altonsegal
FAX : (82-32)876-4696 http://www.hynux.com
INPUT
LOAD
RTX+
RTX-
+
ch1
(4-20mA Input)
-
+
※ Only one channel can be used
ch2
(4-20mA Input)
-
+
ch3
(4-20mA Input)
-
ALARM 1
(Caution)
ALARM 2
(Warning)
15
INPUT
24 V d.c.
· Extra input power supply
(For circuit power) : 13, 14
· FAN-driven power source : 15, 16
[Unit : mm]
INPUT
LOAD
per temperature controller.
(Serial connection disabled)
16
13
14
INPUT
100 - 240 V a.c.
loading

Summary of Contents for HANYOUNG NUX TPR-3SL-EP

  • Page 1 (021)33985010-33985020 www.AltonSegal.com telegram.me/altonsegal Power REGULATOR telegram.me/altonsegal TPR-3SL-EP INSTRUCTION MANUAL Thank you for purchasing HANYOUNG product. Please check whether the product is the exactly same as you ordered. HANYOUNGNUX CO.,LTD Before using the product, please read this instruction manual carefully. 28, Gilpa-ro 71beon-gil, Nam-gu, Incheon, Korea...
  • Page 2 (021)33985010-33985020 www.AltonSegal.com telegram.me/altonsegal Part name and function Appearance █ 40A / 55A / 70A █ 90A █ 130A / 160A 239.1 213.7 220.5 239.1 239.1 194.6 4-6.5 213.7 220.5 213.7 220.5 194.6 4-6.5 194.6 4-6.5 LED display POWER Soft start or RTX+ Signal and UP/DOWN setting volume...
  • Page 3 (021)33985010-33985020 www.AltonSegal.com telegram.me/altonsegal Explanation by address Communication setting (ModBus RTU/ASCⅡ) █ Process (0 ~ 99) Address Parameter Explanation Setting range Unit communication setting AlarmStatus Alarm status information Refer to Bit Information Communication speed 2400, 4800, 9600, 19200 CH1 Status CH1 Status information Refer to Bit Information Communication protocol ModBus RTU...
  • Page 4 (021)33985010-33985020 www.AltonSegal.com telegram.me/altonsegal Explanation about SCR Alarm █ Restart function Alarm Alarm Checking list When a warning or caution alarm occurs, TPR gives alarm 1 or 2 or stop the output. This Description (LED) function is used to return to normal operation mode when factors caused errors are eliminated. 1.

This manual is also suitable for:

Tpr-3sl-040l-epTpr-3sl-055l-epTpr-3sl-070l-epTpr-3sl-090l-epTpr-3sl-130l-epTpr-3sl-160l-ep ... Show all