HANYOUNG NUX TH510 Series Operation Manual

HANYOUNG NUX TH510 Series Operation Manual

Programmable temperature & humidity controller
‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬
021-33989001
www.sivancarno.com
021-33989002
Table of Contents
loading

Summary of Contents for HANYOUNG NUX TH510 Series

  • Page 1 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 021-33989001 www.sivancarno.com 021-33989002...
  • Page 2 Notice This operation manual is protected by copyright and has all rights concerned. Without prior consent from Hanyoung Nux Co., Ltd., any part of this document will not be copied, reproduced, modified, or translated into another language. This operation manual is provided "as is" and may be subject to changes without prior notice.
  • Page 3: Table Of Contents

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Before starting 1. Checking of components 2. Safety cautions 3. Warranty Installation 1. Installation site & cautions 2. How to install 3. Exterior & panel dimensions 4. Wiring 5. Terminal connection diagram 1. Name of section Operation 2.
  • Page 4: Before Starting

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Before starting Many thanks for buying the Hanyoung Nux temperature/humidity controller TH510! The temperature/humidity controller TH510 is designed to control the temperature and humidity in thermo-hydrostats. It consists of display and control units The display can be attached to a panel or VESA-mounted and is connected to the control for communication.
  • Page 5 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Suffix code Model Code Description TH510- ☐ ☐ ☐ Programmable temperature/Humidity controller Display(5.7" TFT LCD) Display None 8 input points/6 output points(1 module)+Power module +Control module 8 input points/14 output points(2 modules)+Power module +Control module Input/output 16 input points/16 output points(3 modules)+Power module...
  • Page 6: Safety Cautions

    •Failure attributable to a natural disaster (e.g. fire, flood, etc.) •Failure attributable to relocation after installation •Failure attributable to unauthorized modification or damage •Failure attributable to unstable power supply ● If you require A/S, contact your dealer or Hanyoung Nux Co., Ltd.. 021-33989001 www.sivancarno.com 021-33989002...
  • Page 7: Installation

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Installation 1. Installation site & cautions ● It may cause electric shock so install in on the panel first. ● Avoid following locations. • Where people might unintentionally contact a terminal • Where there is strong vibration, impact, or electromagnetic field •...
  • Page 8 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶Display (1) How to install the panel Fig. 1) How to install the panel The tightening torque must be 0.5 N·m or less for clamping. Forcible tightening may lead to deformation or damage. Caution (2) How to install VESA mount Connect an M4 X 7L bolt into a VESA hole.
  • Page 9 DIN rail and press it(B) in up the mounting bracket. order to install it. ● How to install module TH510 series module can connect up to 7 units. Any module must be installed vertically. TM-DO TM-DO TM-DO TM-DO TM-DO ①...
  • Page 10: Exterior & Panel Dimensions

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 2) How to attach panel ① Referring to the hole dimensions on the left, find where to install it. ② Push outside the top and bottom hooks for fixing screws at the bottom of modules. ③...
  • Page 11 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶Power module (Unit : ㎜) 112.0 50.0 17.0 73.2 13.8 13.0 95.0 ▶Control, input, output, and input/output modules (Unit : ㎜) 112.0 40.0 13.0 17.0 73.2 13.8 75.0 42.3 145.0 24.7 4-M4 DC 5V COM1 COM2 95.0...
  • Page 12: Wiring

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 4. Wiring Before wiring, disconnect the power. Do not touch a terminal because it may lead to electric shock. Caution ▶ Power connection Vinyl-insulated wire(0.9 - 2.0 ㎟ (KSC 3304)) must be used. Too much noise may lead to damage or malfunction to the device.
  • Page 13: Terminal Connection Diagram

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ●Temperature / Humidity control and transmission output wiring ●Temperature/Humidity control output ●Temperature/Humidity transmission output SSR or SCR Recording and indicating instrument, etc.. ▶ Communication wiring Connect terminating resistors(100 - 200 Ω, 0.25 W) at both ends of communication cable. Master TH510 Terminating...
  • Page 14 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Power module ▶ Control module POWER MAIN POWER MAIN TM-PWR TH510-MAIN TM-DIO TM-DI TM-DO TM-PWR Terminal Terminal TH510-MAIN TM-DIO TM-DI TM-DO Temperature Humidity COM1 COM2 COM1 COM2 DC 5V SSR/SCR DC 5V SSR/SCR COM1 COM1...
  • Page 15: Operation

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Operation 1. Name of section Front LED Display SD card slot Power switch Fig. 5) Main menu [ Front LED ] Back light OFF STOP (Red lamp ON), RUN (Red lamp flashing) Back light ON STOP (Green lamp ON), RUN (Green lamp flashing ) 021-33989001 www.sivancarno.com...
  • Page 16: Button Operation

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 2. Button operation Run button Runs corresponding operation immediately. Select button Select one of the displayed items Displays ansets numbers and characters. Input box Press it to display the numeric or character input panel. ※...
  • Page 17: How To Control Character Input Panel

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 4. How to control character input panel Fig. 7) Character input panel Displays parameter names. Displays setting characters. Registers setting characters. Remove the last digit of setting characters. Remove the entire setting value. Cancel setting and hide input panel.
  • Page 18: Name Of Control

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 5. Name of control ▶ Control module [ LED specifications ] Lamp ON with power connected. Lamp OFF with power disconnected. COM1 Displays communication state of the display and control. (OFF when OK.) COM2 Displays communication state of the control and I/O.
  • Page 19: Screen Block Diagram

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Screen block diagram 1. Screen block diagram Power ON Splash Operation screen1 Operation screen2 Graph view screen Operation screen1, Operation screen2, and Graph view screen Operation screen Operation setting : Constant-value/program, change rate, fuzzy, and channel tag settings Function setting : Power saving operation, buzzer, recovery of power failure, operation screen, and switch time settings Save setting : Save interval, media, and parameter upload/download settings...
  • Page 20 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Function setting f you press after gIvIng power the screen below appears ① ② ③ ④ ⑤ ⑥ ⑦ Fig. 8) Main menu Name Description Run screen Go to operation screen[Constant-value/Program]. Function Go to operation setting screen. PV graph view Go to saved PV graph screen.
  • Page 21: Operation Screen

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 1. Run screen Fixed control / program operations can be changed from [main menu] - [temperature operation setting] - [ operation setting ]. The operation start and finish can be executed from the operation screens 1 and 2 only 1-1 Fixed control screen ▶...
  • Page 22 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Fixed control screen 2 To start the fix run mode, press the play button (19) in the left of the center in the fix stop mode 2 ② ③ ④ ⑩ ⑦ ①...
  • Page 23 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Fixed control screen 3 ① ② ③ ⑤ ④ Fig. 13) Fixed control screen3 Description Run hidden menu pane. Click the same to hide menu pane. Go to constant-value operation 1 window. Go to main menu screen.
  • Page 24 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ● How to Auto Tuning PID auto tuning is a function for the controller to automatically measure characteristics of control target in order to calculate and set best PID values. Auto tuning gives ON/OFF control output based on the setting values and calculates PID integer by measuring hunting cycle and amplitude.
  • Page 25 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Program operation screen ▶ Program operation 1 screen Press Run button in the center left of stop screen of program operation screen 1 in order to switch to the program operation 1 operation screen. ②...
  • Page 26 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Program operation 2 screen To run the Program operation screen 2 please press the play button (19) in the left of the center. ② ③ ④ ⑩ ⑦ ① ⑥ ⑧ ⑤ ⑨...
  • Page 27 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Program operation 3 screen (Graph view screen) ① ② ③ ⑤ ④ Picture 20) program operation 3 screen Description Runs hidden menu window. Click the same to hide menu window. Go to program operation 1 screen. Go to main menu screen.
  • Page 28 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ● Step/Hold This function is enabled only during program operation. Enter a key or set Hold/Step in [System menu] – [DI configuration] – [Configuration type] and then set external contact input2(DI2) to ON for Hold or external contact input3(DI3) to ON for Step.
  • Page 29 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ PAUSE FUNCTION Fig. 24) Pause screen in program stop mode Fig. 25) Program operation in program stop mode If the operation stops due to DI error, the pause function maintains the program during the error correction, and then goes again to the running program.
  • Page 30: Operation Setting

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 2. Operation setting Screen for operation screen, operation, and data save settings. ▶ Operation setting ① ② ③ ④ ⑤ Fig. 26) Operation setting ① Select a control method. Parameter Description Fixed To control temperature with certain setting value(SV). To control measurement with change of setting values over time.
  • Page 31 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Indication value Sub-SV Target set value Indication value Time Start of fuzzy inference ▶ Function setting ① ② ③ ④ ⑤ ⑥ ⑦ Picture 27) function setting ① Control brightness of LCD screen in 8 steps. Press “◀” to dim it and “▶” to brighten it. ②...
  • Page 32 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ [Function setting parameter] Parameter Setting range Default Screen brightness adjustment 8 stages 3 stages Power saving operation time 0 ~ 99 [minutes] 30 minutes Recovery after power failure STOP, COLD, HOT STOP BEEP sound Cancel/Set Touch input lock Cancel/Set...
  • Page 33 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ [Function setting parameter] Parameter Setting range Default Save interval (Sampling time) 1 ~ 360 [sec] Storage media Internal, SD, and All Item to send Pattern, Parameter, and All Parameter Download Upload ● Upload/Download screen Fig.
  • Page 34 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ● Screen by selection Fig. 33) Line thickness-2 pixels Fig. 34) Line thickness-1 pixel Fig. 35) Background color-Black ▶ Ambient picture 36) ambient ① Set the ambient operation time Parameter Setting range Default ambient operation time 0~9999[min] 021-33989001...
  • Page 35: Pv Graph View

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 3. PV graph view Screen to check graph of files saved in the internal memory or SD card. ⑤ ④ ③ ② ① ⑥ ⑩ ⑧ ⑮ ⑪ ⑭ ⑨ ⑫ ⑬ ⑯ ⑰...
  • Page 36 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ① ② ④ ③ ⑤ ⑥ Fig. 38) PV graph view – Size scale Description Go to max value of data. Go to previous pixel. Press and hold it to move by 10 and 20 pixels. Go to next pixel.
  • Page 37: Time/Schedule Setting

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 4. Time/schedule setting Screen to set current time and schedule. Schedule can be repeated by day. ① ② Picture 40) time/schedule setting Description Set the present time. It is not possible to change while saving Set the operation start schedule time ※...
  • Page 38: Event

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 5. Event Screen to show event or error history. ▶ Event Displays history of up to 80 events. ① ② ③ Fig. 41) Event history Description Go to other pages. History of up to 80 items can be checked. Initialize event history.
  • Page 39 Event message Description ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Hold function start (manual) Hold started by HOLD button Hold function start(communication) Hold started by communication Hold function start(DI2) Hold started by contact input (DI2) Hold function stop(manual) Hold stopped by HOLD button Hold function stop(communication) Hold stopped by communication Hold function stop(DI2) Hold stopped by contact input (DI2)
  • Page 40 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Error Displays history of up to 40 errors. ① ② ③ Fig. 42) Error history Description Go to other pages. History of up to 40 items can be checked. Initialize error history. (enabled when it is not being saved) Save error history to SD card.
  • Page 41: Program

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ PROGRAM Fig. 43) Main menu Fig. 44) Program menu Program control is the process of control measurements with a change in the set value according to the time. This is particularly widely used in environmental testing equipment such as thermostatic humidity chamber, electric furnace, etc.
  • Page 42 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Seg ① ② ③ ④ Fig. 47) segment setting Description Set the temperature settings (value) of the segment. Set the humidity settings (value) of the segment Set the operation time of the segment Select the standby feature in “standby/start pattern management”...
  • Page 43 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ T.S Fig. 48) Time signal Among 20 time signals, up to 4 of them can be selected for a segment. [T.S parameter] Parameter Setting Default T.S #n 0~19 n : 1~4 ▶ Alarm Fig.
  • Page 44: Pattern Management

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 2. Pattern management ▶ Pattern information ① ② ③ ④ ⑤ ⑧ ⑥ ⑨ ⑦ Fig. 50) Pattern information ① Select a pattern. Parameters can be set for individual patterns in this screen. ②...
  • Page 45 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ● Wait operation Wait time setting Wait time Wait operation Wait range Wait range Wait operation Wait operation is cancelled because PV is within defined wait range Wait operation is Wait operation is cancelled because Wait operation is started because...
  • Page 46: Pattern Name Setting

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Copy/Delete ④ ① ② ③ ⑤ ⑥ Fig. 52) Pattern copy/deletion ① Select an original pattern. ② Select a target pattern. ③ Copy the pattern. ④ Select a patter No. to delete. ⑤...
  • Page 47: Pattern Alarm Setting

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 4. Pattern alarm setting ① ② ③ ④ ⑤ ⑥ ⑦ Fig. 54) Pattern alarm ① Select an alarm target. ② Select an alarm type. ③ Set a setting value(offset). ④ Set hysteresis. ⑤...
  • Page 48: Time Signal Setting

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 5. Time signal setting Fig. 55) Time signal Up to 20 time signals can be set. ① Set OFF time. Time signal is on after waiting for defined time from the start point of segment. ②...
  • Page 49: Pattern Graph

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 6. Pattern graph For program operation, pattern and time are shown in a graph. ④ ① ③ ② ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ Fig. 57) Pattern graph Fig. 58) Pattern graph - Operation Description Go to program menu screen.
  • Page 50: System Setting

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ System setting ▶ Access to system setting Caution: System setting is a pre-installed basic setting condition so you need special attention when you change them. There is no need for operators to set system unless Danger special case, strict care is required when changing System settings.
  • Page 51: Sensor Input Setting

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 1. Sensor input setting ▶ Temperature/Humidity Settings Fig. 60) Temperature sensor change Fig. 61) Temperature sensor change 1. Sensor type - Select a sensor type. It can't be changed when it is being saved. - If the type of sensor is changed, related parameters(use range) are initialized so set the type of sensor first.
  • Page 52 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ● Temperature Parameter Setting range Default Sensor Type Please refer to the table of temperature range by sensor type PT-2 RTD High setting limitation/ RTD only available with the default setting/DCV sensor range RTD upper limit DCV Input High setting limitation RTD low setting limitation/ RTD only available with the default setting/DCV sensor range RTD lower limit...
  • Page 53 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Other Settings Fig. 66) Dry/Wet-bulb compensation 1. Humidity Control Rage -Set the humidity range requiring humidity controlling -If the value is outside the range, the value is not indicating, and control out put is off. 2.
  • Page 54: Control/Transmission Output

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 2. Control/transmission output setting ▶ Temperature/Humidity Control output Fig. 67) Temperature Control output Fig. 68) Humidity Control output 1. Control mode - Select control mode 2. SSR Period - Set the control output period when SSR mode is selected 3.
  • Page 55 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ● Humidity Parameter Setting Range Default Output mode SSR, SCR SSR Period 1 ~ 1000 Output direction Direct, Reverse Reverse AUTO, MANUAL AUTO ARW Value 50 % ~ 200 % 100 % SSR cycle Fig.
  • Page 56 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Temperature/Humidity Retransmission Output Fig. 71) Retransmission Setting 1. Output Type - The selected output type is used for inputing data to recorders etc. Output signal is 4-20mA d.c., select between PV, MV, SV. 2.
  • Page 57: Pid Setting

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 3. PID setting ▶ PID setting Fig. 72) PID setting 1. Zone selection type - Set PID zone selection type. 2. PID control type 3. Copy PID time constant - Original channel : No. of original channel - Target channel : No.
  • Page 58 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Fig. 73) Change of control characteristics(PV) according to changed auto-tuning gain ● Auto tuning gain(A/T gain) Condition Unit With stronger derivative and integral controls than auto-tuned PID value, overall GAIN < 1.0 response speed becomes faster but the hunting may be more. GAIN = 1.0 Auto-tuned PID value is used as is.
  • Page 59 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ PID value Fig. 75) PID value 1. Proportion(P) zone - Set proportional band. If the proportional band is larger, control output becomes smaller for the offset and thus the setting value is reached later. If the proportional band is smaller, control output becomes larger for the offset and thus the setting value is reached quicker but there might be hunting if it is too quick.
  • Page 60: Inner Signal

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ HYS. Delay HYS. Delay HYS. Delay Narrow proportional band - quick response, hunting Hysteresis Hysteresis Wide proportional band-Late response and offset from the SV Time Fig. 77) Proportional control (P control) Fig. 76) ON/OFF control Short differential second Offset PI control...
  • Page 61 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 4. Operation range - Set upper and lower limits of operation range for target. 5. Operation delay - Set operation delay for target. 6. Operat;ion Mode - Always : always execute the inner signal - Running : execute the inner signal during operation only Parameter Setting range...
  • Page 62 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Temperature Temperature Time Time Temperature Temperature Fig. 84) Example of inner signal setting (NSV) Fig. 85) Example of inner signal setting (TSV) Temperature Fig. 81 is an example of setting inner signal(I.S) NSV. Inner signal No. 1 - 3 and 8 are set with Temperature temperature, NSV, and Within range so that the inner signal is turn on or off according to change of current setting value(SV).
  • Page 63: On/Off Signal

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 5. ON/OFF signal ▶ Temperature/Humidity setting Fig. 88) ON/OFF – Temperature Fig. 89) ON/OFF – Humidity 6 Points for temperature, 2 points for humidity are available for ON/OFF signal 1. L.SV - Set lower limit of ON/OFF signal operation. 2.
  • Page 64 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Zone D Zone C Zone B Zone A High temperature temperature Fig. 90) ON/OFF zone separation Setting item Function L.SV Low set value Set lower limit. M.SV Middle set value Set median. H.SV High set value Set upper limit.
  • Page 65: System Alarm

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 6. System alarm ▶ Alarm setting Temperature/humidity alarm set screen. Totally 8 alarm signals setting possible. ① ② ③ ④ ⑤ ⑥ ⑦ Fig. 93) System alarm – Temperature Fig. 94) System alarm - Humidity 1.
  • Page 66: Di Configuration

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ System alarm name setting - Click the icon on upper left of alarm setting screen in order to go to the system alarm name setting screen. Fig. 95) System alarm name Fig. 96) Enter a system alarm name 1.
  • Page 67 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Parameter Setting range Default DI input state Always and During operation Always Buzzer ON time 0 ~ 9999 Min. 59 Sec. 0Sec. Detection delay 0 ~ 9999 Min. 59Sec. 0Sec. ▶ Configuration type Fig.
  • Page 68 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Configuration setting Fig. 99) DI configuration setting 1. Operation after detection - Error stop : DI error shows DI error screen and stops operation. - Time stop : DI error shows DI error screen and stops operation after the setting time is elapsed. - Error operation : DI error shows DI error screen and continues operation.
  • Page 69 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Contact type Fig. 102) DI contact type 1. Set contact type. - Contact A : DI runs if a DI contact is connected. (Normal Open) - Contact B : DI runs if a DI contact is disconnected. (Normal Close) ▶...
  • Page 70 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ② ① ④ ⑤ ③ Fig. 104) DI error image upload Fig. 105) Confirm DI error image upload 1. There is no user-defined image in SD card. 2. There is a user-defined image in SD card. 3.
  • Page 71: Do Configuration

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 8. DO configuration DO configuration setting has 8 tabs and assigns system signals to relay outputs. If duplicate relay numbers are set, the relays works even one of them is output. IO specifications are optional for TH510 and configurable relay numbers are limited by the option so make sure to check the IO specifications.
  • Page 72 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ ON/OFF signal - It is the screen in which you can set the relay and delay time about the ON/OFF signal of temperature (6) and humidity (2) - The set ON/OFF signal, if the condition occurs, if after the setting time it turns ON, it operates just during the first ON Fig.
  • Page 73 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Alarm - Screen to set relays for pattern/system alarms. - If an alarm signal is transmitted, defined relay is ON. Fig. 112) DO – Alarm signal Parameter Setting range Default P. Alarm 1 ~ 4 Up to 0 ~ 32 S.
  • Page 74 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Parameter Setting range Default Temperature control signal rely Max 0 ~ 32 Temperature control signal delay 0 ~ 9999 0 sec Humidity control signal rely Max 0 ~ 32 Humidity control signal delay 0 ~ 9999 0 sec Temperature sensor burnout relay...
  • Page 75 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Chamber signal - Operator can set relay of signals relating to operation Fig. 115) DO-Chamber signal Name Description Running Setting relay and delay time of running signal. After delay time, relay start operating Setting relay and holding time of DI signal.
  • Page 76 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Operation signal - Logic operation signal for output signal used to program up to 6 lines. Logic operation is conducted from line No.1 to 6 in order. Fig. 115-1) DO – Operation signal 1) Operation value 1 and Operation value 2 - Select a relay for operation.
  • Page 77: System

    Fig. 117) Specifications screen [ Specifications parameter ] Parameter Setting range Default Information 1 Character input panel(up to 30 characters) HANYOUNG NUX CO.,LTD Information 2 Character input panel(up to 30 characters) TH510 TEMP/HUMI CONTROLLER Information 3 Character input panel(up to 30 characters) www.hynux.com...
  • Page 78 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Communication setting Select a stop bit. Select a communication protocol. Select a communication speed. Select a data length. Enter a unit No. Enter response time. Select a parity bit. Fig. 118) Communication setting screen [ Communication setting parameter ] Parameter Setting range...
  • Page 79 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Memory Displays used/free space of internal memory. Initialize error history. (It can't operate when it is being saved) If initialized, data can't be recovered so send it to an SD card before. Caution Displays used/total space of SD card memory.
  • Page 80 •User attention is required for upgrading firmware so make sure to set the password. Default password is "0". Upgrade files can be downloaded from "Hanyoung Nux" website. Do not change a file name and place it in TH510_FWUP folder in the root directory of SD card to read it. If the firmware is upgraded, the Caution parameters are initialized.
  • Page 81: Specifications

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ Specifications 1. Input specifications [ Range configuration by input type ] Temperature Humidity Input type Measuring range (℃) accuracy Measuring range (%RH) accuracy Pt-1 -100.0 ~ 300.0 Pt100 Ω Pt-2 -100.00 ~ 150.00 Thermoresistor ±0.1 % of F.S (RTD)
  • Page 82 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Output specifications A Contact 30 V DC 3 A max, 250 V AC 3 A Contact output(DO) Up to 32 relay B Contact NO : 30 V d.c. 5 A max, 250 V AC 5 A SSR output ON : 18 V DC Pulse voltage(800 Ω...
  • Page 83: Display Specifications

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ ▶ Control function 1 Temperature contact : EUS(0~100 %) Input calibration(Sensor bias) 1 Humidity contact : EUS(0 ~ 100 %) Dry/wet-bulb sensor Compensate the dry/wet sensor difference after compensation removing the gauze of the wet-bulb sensor. Input DC voltage(VDC) : Input scaling according to Scaling...
  • Page 84: Memory Specifications

    ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ 4. Memory specifications Internal memory Non-volatile memory : 80 MB – Saving of 15 days at 1 S interval External memory SD card(2 GB) : Saving of 1 year at 1 S interval Saving interval 1 - 360 S Program information, setting value, recovery, and temperature setting/...
  • Page 85 ‫ﴍﮐﺖ ﺳﯿﻮان ﻤﻧﺎﯾﻨﺪه اﻧﺤﺼﺎری ﻣﺤﺼﻮﻻت ﻫﺎﻧﯿﺎﻧﮓ ﮐﺮه‬ MA0803E170217 Hanyoung Nux Co., Ltd. 28, Gilparo 71-beongil, Namgu, Incheon, Korea www.hynux.com TEL : (82-32)876-4697 FAX : (82-32)876-4696 021-33989001 www.sivancarno.com 021-33989002...

This manual is also suitable for:

Th510-main

Table of Contents