Ul And Csa Checklist; Design Lifetime Expectancy; Eu Declaration Of Conformity (Machinery Directive) - ABB ACQ580-34 Hardware Manual

Drive modules
Hide thumbs Also See for ACQ580-34:
Table of Contents

UL and CSA checklist

WARNING!
Operation of this drive requires detailed installation and operation instructions
provided in the hardware and software manuals. The manuals are provided in
electronic format in the drive package or on the Internet. Keep the manuals with
the drive at all times. Hard copies of the manuals can be ordered through the
manufacturer.
• Make sure that the drive type designation label includes the applicable marking.
• DANGER - Risk of electric shock. After disconnecting the input power, always wait for
5 minutes to let the intermediate circuit capacitors discharge before you start working on
the drive, motor or motor cable.
• The drive is to be used in a heated, indoor controlled environment. The drive must be
installed in clean air according to the enclosure classification. Cooling air must be clean,
free from corrosive materials and electrically conductive dust.
• The maximum surrounding air temperature is 40 °C at rated output current. The output
current is derated for 40 ... 55 °C.
• The drive is suitable for use in a circuit capable of delivering not more than 100 kA rms
symmetrical amperes, 600 V maximum when protected by the UL fuses given elsewhere
in this chapter.
• The cables located within the motor circuit must be rated for at least 75 °C in UL-compliant
installations.
• The input cable must be protected with fuses or circuit breakers. These protective devices
provide branch circuit protection in accordance with the national regulations (National
Electrical Code (NEC) or Canadian Electrical Code). Obey also any other applicable
local or provincial codes.
WARNING!
The opening of the branch-circuit protective device may be an indication that
a fault current has been interrupted. To reduce the risk of fire or electric shock,
current-carrying parts and other components of the device should be examined
and replaced if damaged.
• The drive provides motor overload protection. For adjustments, see the firmware manual.
• The drive overvoltage category according to IEC 60664-1 is III

Design lifetime expectancy

The design lifetime expectancy of the drive and its overall components exceeds ten (10)
years in normal operating environments. In some cases, the drive can last 20 years or more.
To achieve a long lifetime of the product the manufacturer's instructions for sizing the drive,
installation, operational conditions and preventive maintenance schedule shall be followed.

EU Declaration of Conformity (Machinery Directive)

See
The Safe torque off function (page 193)
Technical data 181
Table of Contents