Page 1
LH2H LH2H PRESET HOUR METER Hour Meter FEATURES 1. Preset function equipped in half size 3. 8.7 mm 0.343 inch Character Height (24 × 48 mm 0.945 × 1.890 inch). (previously 7 mm 0.276 inch) 2. Display has backlight for instant Easy-to read character height increased recognition.
LH2H SPECIFICATIONS Item Descriptions Rated operating voltage 24 V DC Rated power consumption Max. 1.5 W Rated control output 100 mA 30 V DC Time counting direction Addition or Subtraction (selectable by front switch) 0 to 999999.9h/0 to 3999d23.9h (selectable by slide switch on side) Measurement time range 0 to 999h59m59s/0 to 9999h59.9m (selectable by slide switch on side)
Page 3
LH2H Dimensions inch General tolerance: ±1.0 ±.039 • External dimensions 44.8 1.764 54.4 2.142 10.4 .409 1.732 .197 1.890 LH2H HOUR METER .866 .945 RESET MODE .276 • Panel cut out dimensions • For connected installation (sealed installation) The standard panel cut out is shown below.
Page 4
LH2H 4. Time counting direction setting 2) The display after entering the time 4) Pressing the front panel reset key sets mode counting direction setting mode reads the content displayed and returns you to This is the mode for setting addition or “...
LH2H Operation mode Operation mode Explanation Time chart • Elapsed value does not clear at power ON. (Power outage countermeasure function) Power supply T=t1+t2 T>ta • The output remains ON even after the Totalizing ON delay Output power is OFF and restarted.
Page 6
LH2H_Preset.fm Seite 128 Donnerstag, 24. Juni 2004 3:37 15 LH2H PRECAUTIONS IN USING THE LH2H SERIES CAUTIONS FOR USE 1. Insulation sheet • LH2H preset hour meter Before using a panel mounting type, 1) When using the waterproof type (IP66:...
Page 7
2. Installation parts Panel cover (black) Mounting frame Suitable for installation frame type LH2H hour meter and LH2H preset hour meter Part No.: ATH3801 You can change the design of the front panel by replacing it with this black panel cover.