Honeywell Centra Line EAGLE Installation & Commissioning Instructions

Honeywell Centra Line EAGLE Installation & Commissioning Instructions

EAGLE Controller
Safety Information ................................................................ 2
General Safety Information ............................................... 2
Information as per EN 60730 ............................................ 2
WEEE Directive ................................................................ 2
Standards, Approvals, etc. ................................................ 2
Specifications of Controller ................................................. 3
System Overview .................................................................. 3
Overview of Models .......................................................... 3
System Architecture .......................................................... 4
Bus and Port Connections ................................................ 5
LEDs ................................................................................. 6
RS485 Interfaces .............................................................. 6
RS485 Standard ............................................................... 8
Mounting/Dismounting ........................................................ 9
Before Installation ............................................................. 9
Dimensions ....................................................................... 9
Wiring and Set-Up .............................................................. 10
General Safety Considerations ....................................... 10
Wiring Terminals ............................................................. 10
Power Supply .................................................................. 10
Terminal Assignment ...................................................... 11
RIN-APU24 ..................................................................... 12
Lightning Protection ........................................................ 12
CLEA2026Bxx Connection Examples ............................. 13
Internal I/Os of the EAGLE ............................................. 15
Engineering, Commissioning ............................................ 17
Required Preparations .................................................... 17
Extra Parts .......................................................................... 18
® U.S. Registered Trademark
Copyright © 2012 Honeywell Inc. • All Rights Reserved
Installation &
Commissioning
Instructions

TABLE OF CONTENTS

 
Panel Bus Connection ....................................................... 19
 
Considerations ............................................................... 19
 
Connecting RS485-1 to Panel Buses ............................. 20
 
Connecting RS485-2 to Panel Buses ............................. 21
 
Cable Specifications ....................................................... 22
 
BACnet MS/TP Bus Connection ....................................... 23
Considerations ............................................................... 23
 
 
 
 
Troubleshooting ................................................................ 25
 
EAGLE Controller Troubleshooting ................................ 25
 
Panel Bus I/O Module Troubleshooting .......................... 25
 
Appendix 1: Earth Grounding ........................................... 26
 
EAGLE Systems and SELV ........................................... 26
 
 
 
Appendix 2 ......................................................................... 28
 
Sensor Input Accuracy ................................................... 28
 
 
Sensor Characteristics ................................................... 28
 
Index ................................................................................... 30
 
 
 
 
Trademark Information
 
LON, L
W
ON
Corporation registered in the United States and other
 
countries.
 
, and Neuron are trademarks of Echelon
ORKS
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
EN0Z-0970GE51 R1112
Table of Contents
loading

Summary of Contents for Honeywell Centra Line EAGLE

  • Page 1: Table Of Contents

    , and Neuron are trademarks of Echelon ORKS Corporation registered in the United States and other Required Preparations ............ 17   countries. Extra Parts ................18   ® U.S. Registered Trademark Copyright © 2012 Honeywell Inc. • All Rights Reserved EN0Z-0970GE51 R1112...
  • Page 2: Safety Information

    Device meets EN 60730-1 and EN 60730-2-9. Use only accessory equipment which comes from or has ► Refer to Code of Practice standards IEC 61000-5-1 and -2 been approved by Honeywell. for guidance. The device complies with ETHERNET Protocol versions Information as per EN 60730 IEEEC 802.3.
  • Page 3: Specifications Of Controller

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS SPECIFICATIONS OF CONTROLLER Table 2. EAGLE specifications Power supply 19 … 29 VAC or 20 … 30 VDC typically dc: 5 W; max. 6 W Power consumption typically ac: 9 VA; max. 11 VA typically dc: 210 mA;...
  • Page 4: System Architecture

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS System Architecture An EAGLE System consists of the EAGLE Controller and various Panel Bus I/O modules. The EAGLE Controller provides interface connections, which allow connection to external systems (e.g., BACnet controllers). Via the IF-LON External interface, the EAGLE can also communicate with L systems, including CentraLine L I/O Modules.
  • Page 5: Bus And Port Connections

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS Bus and Port Connections USB 2.0 Host Interface Via its USB 2.0 Host interface, the EAGLE Controller can be connected to, e.g., the IF-LON External Interface Adapter and thus to L networks. See also IF-LON External WARNING ORKS Interface Adapter –...
  • Page 6: Leds

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS Ethernet Interface The L network is insensitive to polarity, eliminating ORKS the possibility of installation errors due to miswiring. The CLEA2000Bxx + CLEA2026Bxx are equipped with an Different network configurations (daisy-chain, loop, and star Ethernet / RJ45 socket featuring one LED.
  • Page 7 EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS RS485-1 Bias and Termination Resistors RS485-1 is equipped with a three-position slide switch which 550 OHM can be used to switch its bias resistors OFF (position “MID” – BIAS this is the default), ON (position “BIAS”), and ON with an RS485-1 (+) additional 150Ω...
  • Page 8: Rs485 Standard

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS connection be provided for in order to ensure error-free communication between drivers and receivers – unless all of the devices are electrically isolated and no earth grounding 550 OHM exists. RS485-2 (+) IMPORTANT 130 OHM In the case of new EAGLE controller installations, we strongly recommend using a separate signal ground...
  • Page 9: Mounting/Dismounting

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS MOUNTING/DISMOUNTING Before Installation IMPORTANT To allow the evaporation of any condensation resulting from low shipping / storage temperatures, keep the controller at room temperature for at least 24 h before applying power. US requirement, only: This device must be installed in a UL-listed enclosure offering adequate space to maintain the segregation of line voltage field wiring and Class 2 field wiring.
  • Page 10: Wiring And Set-Up

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS WIRING AND SET-UP Fusing Specifications System Fusing General Safety Considerations We recommend that the user equip the system with an  When connecting the EAGLE, both VDE, National Electric external fuse. Code (NEC) or equivalent, and any local regulations must be observed.
  • Page 11: Terminal Assignment

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS Terminal Assignment Table 8. Terminal assignment signal Description 24V-0 supply voltage (GND), internally connected with term. 31 and system GND (term. 19+37) 24V~ supply voltage (24V) not used Binary output 1. N.O. relay contact switching input power connected to terminal 8 Binary output 2.
  • Page 12: Rin-Apu24

    Powering Panel Bus I/O Modules and Field Devices Lightning Protection The EAGLE, Panel Bus I/O modules, and field devices can be Please contact your local Honeywell representative for powered by either separate transformers (see Fig. 19, Fig. 20, information on lightning protection.
  • Page 13: Clea2026Bxx Connection Examples

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS CLEA2026Bxx Connection Examples NTC20kOHM NTC20kOHM ACTIVE SENSOR TOTALIZER CONTACT SENSOR SENSOR 1: GND (24V 0) 1: GND 1: GND 1: GND 1: GND 2: 24V POWER 2: SIGNAL 2: SIGNAL 2: SIGNAL 2: SIGNAL 3: 0...10 VDC 24 25 26 27 28 29 30 31 32...
  • Page 14 EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS ACTIVE SENSOR 1: GND (24V 0) CONTACT 2: 24V POWER 1: GND 3: 0...10 VDC 2: SIGNAL A1 A2 A3 A4 A5 A6 A7 B1 B2 B3 B4 B5 B6 B7 XS830 1 2 3 4 5 6 7 1 2 3 4 5 6 7 24 25 26 27 28 29 30 31 32...
  • Page 15: Internal I/Os Of The Eagle

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS Internal I/Os of the EAGLE 10 VDC The CLEA2000Bxx is not equipped with inputs or outputs. The following sub-sections thus apply only to the 25 k CLEA2026Bxx and CLEA2014Bxx. Universal Inputs 200 k The CLEA2026Bxx is equipped with ten (CLEA2014Bxx: four) universal inputs (UIs) configurable (in CARE).
  • Page 16 EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS The polarity (normal = N.O. contact or reverse = N.C. contact) open circuit ≥ 3000 Ω (24 VDC on BI terminal) configuration defines if a relay is open or closed, depending closed circuit ≤...
  • Page 17: Engineering, Commissioning

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS ENGINEERING, COMMISSIONING For access via USB, the EAGLE Controller has a permanent default IP address 192.168.255.241. Your PC's IP address Please refer also to CARE User Guide (Product Literature must match the EAGLE Controller's default IP address No.: EN2B-0182GE51) for detailed information.
  • Page 18: Extra Parts

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS EXTRA PARTS Table 16. Extra parts order number description removable terminal plugs, push-in type; complete set of 9 plugs (for TPU-45-01 terminals 1 - 47); for the CLEA2014Bxx and CLEA2026Bxx removable terminal plugs, push-in type; complete set of 3 plugs (for TPU-11-01 terminals 1 - 47);...
  • Page 19: Panel Bus Connection

    PANEL BUS I/O CLIOPR822A CLIOPR824A CLIOPR825A CLIOP830A ELECTRONIC MODULES Honeywell Binary Inputs Analog Inputs Analog Outputs 24V Relays CO1 CO2 CO3 CO4 CO5 CO6 NO1 NO2 NO3 NO4 NO5 NO6 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 Install.
  • Page 20: Connecting Rs485-1 To Panel Buses

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS Connecting RS485-1 to Panel Buses NOTE: When connecting RS485-1 of the EAGLE with Panel Bus I/O modules, it is recommended that the slide switch be set to “END.” CentraLine I/O Module CentraLine I/O Module CentraLine I/O Module Com a Com a...
  • Page 21: Connecting Rs485-2 To Panel Buses

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS Connecting RS485-2 to Panel Buses CentraLine I/O Module CentraLine I/O Module CentraLine I/O Module Com a Com a Com a Com b Com b Com b 24V~ 24V~ 24V~ EAGLE 24~0 24~0 24~0 2930 31 GND-2 GND-2...
  • Page 22: Cable Specifications

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS Cable Specifications Panel Bus I/O Modules When checking the length of the power supply cable, the connection cables to all Panel Bus I/O Modules must be taken into account. Table 17. Power supply cable specifications 3 m (from transformer to final module) max.
  • Page 23: Bacnet Ms/Tp Bus Connection

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS BACNET MS/TP BUS CONNECTION The EAGLE Controller features two RS485 interfaces to which BACnet MS/TP devices can be connected: RS485-1 (consisting of push-in terminals 24 [GND-1], 25, and 26) and/or RS485-2 (consisting of push-in terminals 29, 30, and 31 [GND-2]). NOTE: GND-2 is internally connected with 24V-0 (terminal 1) and system GND (terminals 19+37) Considerations...
  • Page 24: Connecting Rs485-2 To Bacnet Ms/Tp Buses

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS Connecting RS485-2 to BACnet MS/TP Buses 120 Ohm EAGLE 2930 31 GND-2 GND-2 550 OHM 130 OHM 550 OHM RS485-2 (+) RS485-2 (-) BACnet BACnet Module #1 Module #N *Connect, if available. 24 V 230 V Fig.
  • Page 25: Troubleshooting

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS TROUBLESHOOTING EAGLE Controller Troubleshooting The following LEDs of the EAGLE Controller can be used for troubleshooting purposes:  Power LED (green)  Status LED (red)  Tx (sending data on the isolated BACnet MS/TP Bus) and Rx (receiving data on the isolated BACnet MS/TP Bus) LEDs Power LED (green) of EAGLE Table 21.
  • Page 26: Appendix 1: Earth Grounding

     Safety against unexpected start-up of against electrical impact. rotating/moving machines To support SELV, all Honeywell external (CRT series) or – If the application/plant does not contain machines that internal transformers comply with standard EN60742. can be harmful to the operator due to an unexpected Earth grounding is therefore not recommended.
  • Page 27: Earth Grounding Of En60204-1 Applicable Systems

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS Earth Grounding of EN60204-1 Applicable Systems If system protective earth grounding is planned, use a ► cable as short as possible for grounding: min. 1.5 mm² (16 AWG). For connection details, refer to the following examples. ►...
  • Page 28: Sensor Input Accuracy

    EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS APPENDIX 2 Sensor Input Accuracy The internal sensor inputs of the EAGLE Controller support NTC20kΩ sensors (see also section “Universal Inputs” on page 15). The following table lists the typical minimum accuracies of the hardware and software for temperature sensors. Table 24.
  • Page 29 EAGLE CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS NTC 20 k (same voltages for Panel Bus I/O Modules and EAGLE) Temp. Resistance Terminal Temp. Resistance Terminal Temp. Resistance Terminal Temp. Resistance Terminal [°C] [k voltage [V] [°C] [k voltage [V] [°C] [k...
  • Page 30: Index

    XW-Online 5 via RS485-1 3, 6 via RS485-2 3, 6 Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: CentraLine Printed in Germany.

Table of Contents