Mounting of Door module RS485 (026593.10) ........
Page 4
Mounting and Connection Instructions - Door module RS485 The following general symbols will be used in the documentation: Warning sign Designates risks for man and/or machine. Non-compliance will create risks to man and/or machine. The level of risk is indicated by the word of warning: Caution! Risk of material and environmental damage.
Mounting and Connection Instructions - Door module RS485 General information Access control systems are required if, access to rooms or buildings is restricted to a certain group of persons only. Software IQ MultiAccess for Windows is the parent user software which offers a powerful and practice-oriented access control system.
Mounting and Connection Instructions - Door module RS485 Outputs: 2 Relays Contact rating: 3 A/24 V DC (e.g. door relay, alarm relay, tamper relay) 1 semiconductor output (active 0 V, max. 15 V DC, 12 mA) The number of the applicable inputs/outputs decreases if two doors are operated via the door module, (See chapter 10.
Mounting and Connection Instructions - Door module RS485 1.2.2 Example IQ MultiAccess With IQ MultiAccess the door module can administrate two doors. Configuration example 1: Just the access to a room is controlled via one reader. It is possible to exit the room without identification.
Mounting and Connection Instructions - Door module RS485 Important installation instructions Protective measures during installation Attention: Switch the mains supply off before opening the device. The VDE regulations and the regulations of the electricity supplier must be observed during installation. Carry out the connections between the control unit and the external devices according to the connection diagrams.
Mounting and Connection Instructions - Door module RS485 Shielding and ground potential The door module devices are daisy chained via a shielded twisted pair cable. Please use Cat 5 or better cable for installation. The shielding of the incoming RS-485 cable is to be connected to the shield terminal bar of the door module.
The Door module RS485 Item no. 026594.10 is delivered with the power supply and charging unit. The Door module RS485 Item no. 026593.10 is delivered without a power supply. Here you are use decentralized power supply by one or more external power supply units distributed throughout the system.
Mounting and Connection Instructions - Door module RS485 Battery Space for a battery in the cover of the housing: 1 x Item no. 018 002 battery 12V 2,0Ah Fix the battery 12 V/2,0A (Item no. 018002) by means of a flexible “Dual Lock” Velcro fastening tape in the cover: Cover with “Dual Lock”...
Mounting and Connection Instructions - Door module RS485 When installing the power supply unit in the central housing, ensure that the isolating shield is placed between the bottom of the housing and the lower side of the board. Also ensure that the device is firmly screwed to the bottom of the housing.
Mounting and Connection Instructions - Door module RS485 Adjust the voltage at the battery terminals by means of the RV2 potentiometer under consideration of the ambient temperature according to the table below. Note the battery type! Warning! Destruction of device possible! The end-of-charging voltagemust only be modified: after having exactly measured the temperature if the battery voltage deviates by >200mV from the nominal value according to the table below...
Mounting and Connection Instructions - Door module RS485 Mounting Mounting of Door module RS485 (026593.10) The door module 026593.10 is deliverd with a plastic housing. If necessary, the pcb can be removed for easier mounting of the housing. To do so push the retainer with notch slightly downwards and remove the pcb from the mounting pillars.
To assure safe and easy working, we recommend removing the holder with integrated tamper switch during the installation of the peripheral devices. Technical data Technical data 026593.10, Door module 12V DC, RS485 Rated operating voltage 12V DC Operating voltage range...
General connection diagram *with Item no. 026593.10 bridge the connection terminal (S) to 0V, otherwise failure message - power suppy unit. If only one reader is used, this reader is to be connected as “Reader 1".
Mounting and Connection Instructions - Door module RS485 Description of fuse, jumpers and LEDs 6.1.1 Fuse SI1 Fuse (250 mA) for reader voltage supply. 6.1.2 Jumpers for level definition According to the used reader set up the level definition “pull down” or “pull up”. Information on the level definition can be found in the “Mounting and Connection Instructions”...
Mounting and Connection Instructions - Door module RS485 6.1.7 DIP switch addresses Set up the BUS address according to the following selection table. A reset or a “power-on reset” must be carried out for any changes in the switch settings to be effective. We recommend to set up the DIP switch before system commissioning.
Mounting and Connection Instructions - Door module RS485 6.1.8 Reader type and card coding Input type: CLOCK/DATA or Wiegand-interface Output type: RS-485 Reader type Remarks Novar contactless Output RS-485 Settings for card coding in the corresponding Novar access control software. HID-Wiegand Output RS-485 Settings for card coding in the corresponding Novar access control software:...
Mounting and Connection Instructions - Door module RS485 Connecting a door strike Connecting a door strike with load current function Strike with load current function: the door is released if the coil is energized. Connecting a no-load current door strike No-load current door strike: the door is blocked if the coil is energized.
Mounting and Connection Instructions - Door module RS485 Electric safety lock The electric safety lock requires certain settings to be made in the Software IQNetEdit. Observe the operating voltage range and current consumption of the electric safety lock! Use an external power supply or connection +12 V DC of the power supply unit.
Mounting and Connection Instructions - Door module RS485 10. Connections Terminal assignment to fill in the lines and colors of the cables. Reader 1 Reader 2 Shield Shield 12V DC 12V DC (max. 100mA) (max. 100mA) Clock / D0* Clock / D0* Data / D1* Data / D1* LED red...