Allen-Bradley 140G Series Adjustment Instructions

Allen-Bradley 140G Series Adjustment Instructions

Lsi-lsig
Hide thumbs Also See for 140G Series:

Quick Links

DIR 1000721R0510 Version 00 - 140G-J-HT_
LSI-LSIG Adjustment instructions for 140G-J 15A
Sganciatori LSI e LSIG
Auslöser LSI und LSIG
Dèclencheur LSI et LSIG
Relé LSI y LSIG
Installation - Installazione - Instalación
Instalação -
WARNING:
To prevent electrical shock, disconnect from power source before
installing or servicing. Install in suitable enclosure. Keep free from contaminants.
(Follow NFPA70E requirements).
AVVERTENZA: Per prevenire infortuni, togliere tensione prima dell'installazione o
manutenzione. Installare in custodia idonea. Tenere lontano da contaminanti.
(Seguire i requisiti NFPA70E).
WARNUNG:
Vor Installations- oder Servicearbeiten Stromversorgung zur
Vermeidung von elektrischen Unfällen trennen. Die Geräte müssen in einem
passenden Gehäuse eingebaut und gegen Verschmutzung geschützt werden. (Befolgen
Sie die Anforderungen nach NFPA70E).
AVERTISSEMENT:
Avant le montage et la mise en service, couper l'alimentation
secteur pour éviter toute décharge. Prévoir une mise en coffret ou armoire appropriée.
Protéger le produit contre les environnements agressifs. (Vous devez respecter la
norme NFPA70E).
ADVERTENCIA: Desconéctese de la corriente eléctrica, antes de la instalación o
del servicio, a fin de impedir sacudidas eléctricas. Instálelo en una caja apropiada.
Manténgalo libre de contaminantes. (Cumpla con los requisitos NFPA70E).
ATENÇÃO: Para evitar choques, desconectar da corrente elétrica antes de fazer a
instalação ou a manutenção. Instalar em caixa apropriada. Manter livre de
contaminantes. (Cumpra as exigências da norma NFPA70E).
警告:感電事故防止のため、取付けまたは修理の際は電源から取り外してく
ださい。適切なケース内に取付けてください。また、汚染物質がないことを
確認してください。(NFPA70Eの要件に従ってください)
警告:为了防止触电,在安装或维修之前必须先切断电源。安装在合适的设备
箱内。防止接触污染 。符合NFPA70E要求)
1
DIR 1000721R0510 Version 00
-
1
CLACK
2
Bul. 140G
140G-J
1
loading

Summary of Contents for Allen-Bradley 140G Series

  • Page 1 Bul. 140G DIR 1000721R0510 Version 00 - 140G-J-HT_ LSI-LSIG Adjustment instructions for 140G-J 15A Sganciatori LSI e LSIG Auslöser LSI und LSIG Dèclencheur LSI et LSIG Relé LSI y LSIG Installation - Installazione - Instalación Instalação - WARNING: To prevent electrical shock, disconnect from power source before installing or servicing.
  • Page 2 Manual default setting Settaggio di default manuale Manuelle Default-Einstellung Configuration par défauit manuelle Ajuste de default manual Color CONDITION Run time Green LED Fixed = Device active LED Fixed = L pre alarm (0,9 * I1 < I < 1,2 * I1) LED Blinking = L alarm (I >...
  • Page 3 Example - Esempio - Beispiel - Exemple - Ejemplo In = 40A I3 = 40x(1,5+5,5)=280A I3 (In) In (A ) 140G-J Example - Esempio - Beispiel - Exemple - Ejemplo In = 40A I4 = 40x(0,2+0,25)=18A t4 = 0,2s @ I>I4 I4 (In) In (A ) 0 ,2...
  • Page 4 TRIP 140G-ELTT CLACK (ordered separately) Allen-Bradley, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. DIR 1000721R0510 Version 00 - L8877 Publication 140G-IN142A-MU-P - January 2016...

This manual is also suitable for:

140g-j