Adjustment functions

Overview of Adjustment
functions menu
9.1

Setting the Maintenance interval

In order to enable the Adjustment functions
menu, first unscrew the cover (1) from the
rear of the BEA. To do so, you must break
the security seal. Behind this cover is a
adjustment switch, with which you can
remove the write-protection of the flash-
prom.
i Remember to set the setting switch
back to Off once you quit the Adjus-
tment functions menu.
Select the menu with the o and u keys
and confirm with E or by double-clicking
the mouse.
In this menu you can enter the interval
between services in days.
If the set time has elapsed, a message
about the next service appears on the
display of the BEA.
! Observe legal requirements when
entering the service interval!
Enter the service interval using the key-
board, e.g. 180.
Confirm your entry with E or by clicking
OK.
The OK box is displayed for 1 s.
The service interval setting function is
now complete.
1
UEA 100/ 150 / 200 / 250
/ 300 / 350
PTB
mit RTM 400
Abgasmeßgerät für
RTM 430 Geräte - Nr.
RWTÜV
Abgasuntersuchungen
nach Nummer 3,1 und 3.2
der Anlage VIII a zu
§ 47 a StVZO i. V. m.
A-13.99.
Gerät ---
einsetzbar.
Geräte Nr.:
NO
2
PTB
XX.XX
XX.XX
Abgasgerät für Motoren mit Fremdzündung
Propane- Faktor:
0,530
Kalibriergas :
Qmax: xxx L/h
Qmin: xxx L/h
Test :
Qsoll:
xxx L/h
Qmin: xxx L/h
Meßbereich:
0. .9999 ppm HC 0. .18..% vol C02
0,5 . . 9,999 Lamda
0. .10 %vol CO
0. .22..% vol C2
02-Sensoren:
Typ R 17 - A
RB-Nr.: 1 687 224 732
Typ A7 - 11.5
RB-Nr.: 1 687 224 843
O IML R99-Class 1
Bj . : xxxx
Bj . : xxxx
Gerät halbjährlich warten !
NO
O
2
cal
BOSCH
Best.- Nr.
Typ
Geräte - Nr.
FD
U ( V )
P ( W )
F ( Hz )
Made in Germany
088
459716/44Ha
Best. Nr. 1687 022 768
FD xxx
GF 3
GF 2
AF 1