9.2 Drive functions
Note when deactivating know-how protection
Note
Permanently or temporarily deactivating know-how protection
Temporary deactivation means that know-how protection is active again after a POWER ON.
Data is still saved on the memory card in an encrypted form. The existing password is used
to reactivate know-how protection.
Final deactivation means that know-how protection is no longer active, even after a POWER
ON. Data is saved on the memory card in an unencrypted form (i.e. data is no longer
encrypted).
Even if know-how protection has been finally deactivated, it can still be reactivated when
required.
9.2.21.4

Changing the know-how protection password

Changing the password for know-how protection can be realized via STARTER in the online
mode.
Changing the password
The password for know-how protection can be changed as follows via STARTER in the
online mode:
● Select the drive unit via Project > Know-how protection drive unit > Change password.
● A dialog appears in which the following entries can be made:
– Enter the old password
– Enter the new password
– Confirm the new password
● After closing the dialog with OK, the changed password is activated.
9.2.21.5
OEM exception list
Setting parameters can be excluded from know-how protection using the OEM exception list.
The parameters contained in the exception list can also be read and changed even when
know-how protection is activated.
The exception list can only be generated via the expert list in STARTER in online mode.
Parameter p7763 is used to define the number of parameters that should be contained in the
exception list. In parameter p7764, in each index, the parameter number that should be
included in the exception list is entered. The exception list can be separately generated for
each drive object.
436
The password must comprise at least one character, it may not exceed a length of 30
characters, all characters are permissible.