Emerson PENBERTHY FHS Installation, Operation And Maintenance Instructions

Automatic liquid heating system

Quick Links

PENBERTHY MODEL FHS AUTOMATIC LIQUID HEATING SYSTEM
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation, these instructions must be read carefully and understood.

TABLE OF CONTENTS

Product warranty ................................................ 1
1
About the manual..................................... 2
2
Introduction ............................................. 2
2.1 Features and specifications ........................ 2
2.2 Design ratings at max. and min.
operating temperatures .............................. 2
2.3 Application data ........................................... 2
3
confirmation ............................................ 2
3.1 Receiving inspection .................................... 2
3.2 User's rating inspection .............................. 2
4
Installation ............................................... 3
4.1 Mounting ....................................................... 3
5
Operation ................................................. 3
5.1 Pre-operational check ................................. 3
5.2 Operating ...................................................... 4
5.3 Shutdown ...................................................... 4
6
Maintenance ............................................ 4
6.1 Preventative maintenance ........................... 4
6.2 Maintenance procedures ............................ 4
6.3 Troubleshooting ........................................... 4
7
Disassembly - reassembly ...................... 5
8
Disposal at end of useful life ................... 6
9
Telephone assistance .............................. 6
10 Exploded parts drawing ........................... 7
Tables and figures
Table 1 - Design ratings at max. and min.
operating temperatures ................... 2
Figure 1 - Installation ......................................... 3
Figure 2 - Reassembly ...................................... 5
Figure 3 - Valve body .......................................... 6
Figure 4 - Exploded parts drawing .................... 7
Figure 5 - Exploded parts drawing (valve) ........ 8
Emerson.com/FinalControl

PRODUCT WARRANTY

Emerson warrants its Penberthy products
as designed and manufactured to be free
of defects in the material and workmanship
for a period of one year after the date of
installation or eighteen months after the date
of manufacture, whichever is earliest. Emerson
will, at its option, replace or repair any products
which fail during the warranty period due to
defective material or workmanship.
Prior to submitting any claim for warranty
service, the owner must submit proof of
purchase to Emerson and obtain written
authorization to return the product. Thereafter,
the product shall be returned to Emerson with
freight prepaid.
This warranty shall not apply if the product has
been disassembled, tampered with, repaired
or otherwise altered outside of the Emerson
factory, or if it has been subject to misuse,
neglect or accident.
The responsibility of Emerson hereunder
is limited to repairing or replacing the
product at its expense. Emerson shall not be
liable for loss, damage or expenses related
directly or indirectly to the installation or use
of its products, or from any other cause or
for consequential damages. It is expressly
understood that Emerson is not responsible
for damage or injury caused to other products,
buildings, personnel or property, by reason of
the installation or use of its products.
This is Emerson's sole warranty and in lieu of
all other warranties, expressed or implied which
are hereby excluded, including in particular all
warranties of merchantability or fitness for a
particular purpose.
This document and the warranty contained
herein may not be modified and no other
warranty, expressed or implied, shall be made
by or on behalf of Emerson unless made in
writing and signed by the company's general
manager or director of engineering.
© 2018 Emerson. All Rights Reserved.
VCIOM-04059-EN 19/04
Table of Contents
loading

Summary of Contents for Emerson PENBERTHY FHS

  • Page 1: Table Of Contents

    6.2 Maintenance procedures ......4 6.3 Troubleshooting ........... 4 This is Emerson's sole warranty and in lieu of Disassembly - reassembly ...... 5 all other warranties, expressed or implied which Disposal at end of useful life ....6 are hereby excluded, including in particular all Telephone assistance ......
  • Page 2: About The Manual

    INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 1 ABOUT THE MANUAL 2.3 Application data The Penberthy FHS is designed to operate This manual has been prepared as an aid and at liquid line pressures from 10 to 100 psig guide for personnel involved in installation or (70 to 690 kPaG), steam pressures from 30 to...
  • Page 3: Installation

    PENBERTHY MODEL FHS AUTOMATIC LIQUID HEATING SYSTEM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 4 INSTALLATION FIGURE 1 Installation should only be undertaken by qualified, experienced personnel who are Steam inlet familiar with this equipment and have read and understand thoroughly all the instructions in this manual.
  • Page 4: Operating

    For detailed information on these establish full flow. Keep it on throughout the safety manuals and inspection details for each entire operation process. operating conditions, request Emerson to specific installation of an automatic liquid supply the relevant technical data sheet. heating system.
  • Page 5: Disassembly - Reassembly

    PENBERTHY MODEL FHS AUTOMATIC LIQUID HEATING SYSTEM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 7 DISASSEMBLY - REASSEMBLY FIGURE 2 WARNING Valve Do not proceed with removal of the FHS from packing Threads to diaphragm connecting piping unless the FHS has been actuator rod relieved of all pressure or vacuum, has been allowed to reach ambient temperature and has...
  • Page 6: Disposal At End Of Useful Life

    8 DISPOSAL AT END OF USEFUL LIFE Installation) and replace the bonnet into the body. g. Hold the valve firmly and replace the cap Penberthy FHS' are used in a variety of fluid screws through the bonnet and wrench applications. By following the appropriate tighten.
  • Page 7: Exploded Parts Drawing

    PENBERTHY MODEL FHS AUTOMATIC LIQUID HEATING SYSTEM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 10 EXPLODED PARTS DRAWING FIGURE 4 PARTS LIST Ref. nr Item Nut jet Disc Steam ring Fitting heater Cross Controller Bracket Valve Valve Strainer Nipple Nipple Thermometer Union Screw Bolt Bushing...
  • Page 8 Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Penberthy is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co.

Table of Contents