June 2019
Figure 2-4: Meter Monitor (Summary) view
Run Daniel MeterLink and open the Meter Monitor (Detailed) view to perform a
diagnostics health check and or adjust parameters for your site requirements. If you wish
to use the Monitor (Detailed) dialog as the default view, click the checkbox in the lower
portion of the dialog box.
Figure 2-5: Meter Monitor (Detailed) view
The following details the information displayed in this dialog box.
Flow Properties Table - the table at the top of the Meter Monitor dialog box shows basic
information about the condition of the flow in the meter.
Flow Velocity/Flow Ratios Bar Graph - provides a visual comparison between the
velocities for each chord.
Chord Speeds of Sound Bar Graph - a visual comparison between the calculated speeds of
sound for each chord.
36
Maintenance and Troubleshooting manual
Gas Ultrasonic Flow Meters