Emerson Daniel 3410 Series Instructions For Use, Maintenance And Installation Manual page 34

Gas ultrasonic flow meters
Hide thumbs Also See for Daniel 3410 Series:
Table of Contents
Troubleshooting
June 2019
Table 2-1: Troubleshooting
Error
No power to the unit
One or more of the chords is not indicating a
reading (reporting zeros)
34
Maintenance and Troubleshooting manual
(continued)
Recommended action(s)
saved configuration files are typically
stored in C:\Ultrasonic Data folder.
Restart the meter to install the firmware.
Daniel MeterLink prompts you with a
message that it must disconnect from
the meter. Once the firmware upgrade is
complete you will be able to reconnect
to the meter with Daniel MeterLink
When the meter restarts, it takes about
two minutes before you will be able to
reconnect depending on the firmware
upgrade being performed. If the
database does need to be reinitialized, it
could take up to five minutes.
After an upgrade, it is recommended to
reconnect to the meter and repeat the
Program Download process.
If all the program components are
successfully updated, they will show to
be the same date and version as the
Currently Installed Versions and the
Download button will be disabled.
If one or more components are still not
updated, click Download to continue the
upgrade process.
Check for correct voltage (10.4 - 36 VDC)
(refer to the System Wiring Diagram P/N
DMC-005324 in
Check the main power source for blown fuse
or tripped circuit breaker. Reference your "as
built" installation drawings for your location.
Check for loose connections at the cable
connectors.
Check the resistance of the transducers
(should be approximately 2 Ω).
Problem also may be caused by a bad
Acquisition Module or interconnect cable.
Check system status in the Daniel MeterLink
program for any flagged errors.
Check the CPU Module.
If Chord A is not indicating, Change the
transducer cables from Chord B to chord A. If
Chord B then fails, the transducers are bad
on Chord A.
P/N 3-9000-769
.
Appendix
B).
Gas Ultrasonic Flow Meters

Hide quick links:

Table of Contents
loading

This manual is also suitable for:

341434123411Daniel 3414Daniel 3412Daniel 3411

Table of Contents