Summary of Contents for Emerson Rosemount FS-HR-975

  • Page 1 User Manual 00809-0900-4975 Flame Simulator: FS-HR-975...
  • Page 3 Legal Notice The Flame Simulator described in this document is the property of Rosemount. No part of the hardware, software, or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Rosemount.
  • Page 4 Warranty Limited Warranty . Subject to the limitations contained in Section 10 (Limitation of Remedy and Liability) herein, Seller warrants that (a) the licensed firmware embodied in the Goods will execute the programming instructions provided by Seller; (b) that the Goods manufactured by Seller will be free from defects in materials or workmanship under normal use and care;...
  • Page 5: Table Of Contents

    Contents Contents Chapter 1 Introduction ........................1 Model and types ..........................1 Features and benefits ........................1 Principles of operation ........................2 Simulator status ..........................2 Product Certification ........................3 Simulator structure ........................3 Certification instructions ........................ 7 Special conditions for safe use ......................8 Chapter 2 Operation Instructions .....................
  • Page 6 Contents...
  • Page 7: Chapter 1 Introduction

    Introduction Introduction To comply with local standards and jurisdictional authorities, end-to end loop testing of fire protection alarm systems, including detectors, should be performed periodically. Many safety authorities and plant managers of high value / high risk assets and facilities insist on quarterly end-to end testing of their entire fire protection systems using an external flame simulator.
  • Page 8: Principles Of Operation

    Introduction Principles of operation The FS-HR-975 emits IR energy, which is filtered to emit electromagnetic radiation in a unique sequential pattern, corresponding to and recognizable as a fire by the Rosemount 975HR Flame Detector. The simulator includes a reflector which accumulates the IR energy and directs it towards the detector.
  • Page 9: Product Certification

    Introduction Product Certification The Flame Simulator is certified to ATEX and IECEx Ex II 2 G D Ex db ib op is IIB + H T5 Gb Ex ib op is tb IIIC T135 °C Db -20 °C to +50 °C (-4 °F to +122 °F) This product is suitable for use in hazardous Zones 1, 2, 21, and 22 with IIB + H gas group vapor present.
  • Page 10 Introduction Figure 1-1: Flame simulator side view Electronic chamber Battery chamber Battery back cover Handle Reflector Push button Sight...
  • Page 11 Introduction Figure 1-2: Flame simulator rear view Handle Reflector Sight Back cover locking screw...
  • Page 12 Introduction Figure 1-3: Flame simulator front view Handle Push button Sight Laser diode...
  • Page 13: Certification Instructions

    Introduction Certification instructions WARNING! EXPLOSION Do not open the detector, even when isolated, in a flammable atmosphere. The equipment marking is defined as follows: Ex II 2 G D Ex db ib op is IIB + H T5 Gb Ex ib op is tb IIIC T135 °C Db -20 °C to +50 °C (-4 °F to +122 °F) The equipment may be used with flammable gases and vapors with apparatus groups IIA and IIB + H...
  • Page 14: Special Conditions For Safe Use

    Introduction Special conditions for safe use The dimensions of the flameproof joints are other than the relevant minimum or maximum values required by Table 2 of IEC/EN 600791-1: 2007 for IIB + H as detailed below. Flamepath description Type of joint Minimum width "L"...
  • Page 15: Chapter 2 Operation Instructions

    Operation Instructions Operation Instructions Ordering information The P/N of the Flame Simulator kit is FS-HR-975. The kit is supplied in a carry case that includes: Flame Simulator: FS-HR-975 Charger Tool kit Technical manual: 00809-0900-4975 Unpacking the product Upon receipt of your detector, check and record the following: •...
  • Page 16: Operating Instructions

    Operation Instructions Operating instructions Prerequisites WARNING! HAZARDOUS AREAS Do not open the Flame Simulator to charge the batteries or for any other reason in a hazardous area. CAUTION! ALARM ACTIVATION The following test simulates a real fire condition and may activate the extinguishing system or other alarms.
  • Page 17: Detection Ranges Per Detector / Flame Simulator

    Operation Instructions Detection ranges per detector / flame simulator Table 2-2: Detection ranges per detector / flame simulator Model Detector types Detector sensitivity Testing distance settings FS-HR-975 975HR 50 ft (15 m) 6.6 ft (2 m) 100 ft (30 m) 19.6 ft (6 m) 150 ft (45 m) 29.5 ft (9 m)
  • Page 18 Operation Instructions Screw in the locking disc (Item C, Figure 2-1). Screw in the back cover (Item C, Figure 1-1). Lock the back cover with the locking screw (Item D, Figure 1-2).
  • Page 19: Replacing The Battery

    Operation Instructions Replacing the battery Place the Flame Simulator on a table in a safe area not exceeding 104 °F (40 °C). Release the locking screw (Item D, Figure 1-2). Unscrew the battery back cover (Item C, Figure 1-1). Unscrew the locking disc clockwise (Item C, Figure 2-1).
  • Page 20: Maintenance

    Operation Instructions Maintenance • Ensure the Flame Simulator is charged before operation. • Ensure the reflector and the window are clean. • Before replacing the battery, ensure that you have a Rosemount battery pack, P/N 00975-9000-0012. • When the simulator is not in use, recharge at least every six months. CAUTION! EQUIPMENT DAMAGE Use only Rosemount replacement battery pack, P/N 00975-9000-0012.
  • Page 21: Technical Specifications

    Operation Instructions Technical specifications 2.9.1 General specifications Temperature range: -20 °C to +50 °C (-4 °F to +122 °F). Vibration protection: 1 g (10 - 50 Hz) 2.9.2 Electrical Specifications Power: 14.8 V (4 x 3.7 V rechargeable lithium ion battery) Max current: 4 A Battery capacity: 2.2 AH Charging time: 2 hours at 2 A...
  • Page 22: Emi Compatibility

    Operation Instructions 2.9.4 EMI compatibility Table 2-4: Immunity tests Title Basic standard Level to be tested Electrostatic discharge (ESD) IEC 61000-4-2 6 kV / 8 kV contact/air Radiated electromagnetic field IEC 61000-4-3 20 V/m (80 MHz to 1 GHz) 10 V/m (1.4 GHz to 2 GHz) 3 V/m (2.0 GHz to 2.7 GHz) Conducted disturbances IEC 61000-4-6...
  • Page 23: Chapter 3 Technical Support

    Technical Support Technical Support For all technical assistance or support contact: Emerson Automation Solutions 6021 Innovation Boulevard Shakopee, MN 55379-9795 T +1 866 347 3427 F +952 949 7001 [email protected]...
  • Page 24 2017 Emerson. All rights reserved. youtube.com/RosemountMeasurement The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a google.com/+RosemountMeasurement mark of one of the Emerson family of companies. All other marks are the property of their AnalyticExpert.com respective owners.

Table of Contents