Operating instructions for users
Control unit
Control 8313
Table of Contents
loading

Summary of Contents for Bosch Control 8313

  • Page 1 Operating instructions for users Control unit Control 8313...
  • Page 2: Table Of Contents

    5.2.4 Off ......... . 17 Advanced functions for heating circuit ... . . 17 Control 8313 – 6720859552 (2017/03)
  • Page 3: Explanation Of Symbols And Safety Instructions

    ▶ Electrical work may only be carried out by an ▶ Read and retain the operating instructions authorised specialist. (heat source, heating controller, etc.) prior to operation. ▶ Observe the safety instructions and warnings. Control 8313 – 6720859552 (2017/03)
  • Page 4: Product Information

    This product contains proprietary software by Bosch (licensed No parameter settings are lost in the event of a power failure. When the according to the Bosch standard licensing conditions) and Open Source power supply is restored, the user interface resumes operation.
  • Page 5: Operation Of The Control Unit

    Reset button (e.g. high limit safety cut-out, SAFe) Chimney sweep button (for Flue gas test) Manual operation key USB connection (e.g. for service purposes) LED status display Data plate F1-, F2 circuit breaker [10] ON/OFF switch Control 8313 – 6720859552 (2017/03)
  • Page 6: Function Buttons And System Status

    The boiler temperature is displayed and the display is disabled in the standard display. To reduce the current consumption of the control unit, the display changes to sleep mode after several minutes. When this happens the display becomes darker. Control 8313 – 6720859552 (2017/03)
  • Page 7: Operating And Display Elements Of The Touch Screen

    [15] Status display of system components levels and operate the functions. The symbols used are listed in  Fig. 11.2 on page 28, accompanied by To go back to the previous level/screen: an explanation. ▶ Tap symbol. Control 8313 – 6720859552 (2017/03)
  • Page 8: Calling Up Menu Levels Or Functions

    Domestic hot water Heating circuit 03 50 °C Heating circuit 01 on/off Heating circuit 04 Heating circuit 02 30 % Heating circuit 05 Heating circuit 07 Heating circuit 06 12:00 0010006538-001 Fig. 9 Selecting the system component Control 8313 – 6720859552 (2017/03)
  • Page 9: Toggling Between Displays

    -or- Fig. 12 Modifying settings ▶ Tap FM-SI field. Numerical values A keyboard opens. Selection box ▶ Enter a suitable text for the length of the field and tap to apply. Scale Cancel Off/On Save Control 8313 – 6720859552 (2017/03)
  • Page 10: Function Keys Of The User Interface

    ▶ Press key again. out or resetting of the SAFe). If the flue gas test is not ended manually, it ends automatically after 30 To unlock a function: minutes. ▶ Key Hold down for 2 seconds. Control 8313 – 6720859552 (2017/03)
  • Page 11: Manual Operation, Emergency Operation

    ▶ Tap the required area in the Info menu. 12:00 0010009883-001 Fig. 16 Overview of Info menu Depending on the area, the following information is e.g. displayed: • Statuses of safety equipment • Temperatures • Operating modes • Hours run Control 8313 – 6720859552 (2017/03)
  • Page 12 You can change the parameter as follows: ▶ Select the heating circuit. ▶ Tap the field. The selection box opens. ▶ Tap the field. ▶ Tap the field. An entry field opens. Control 8313 – 6720859552 (2017/03)
  • Page 13: 3.10.2 Setback Types

    Other control units on the CBC bus can only be accessed from the master control unit. If several control units are linked, the control unit for the system to be operated must be selected first. The other levels (e.g. heating circuits) can then be displayed and selected. Control 8313 – 6720859552 (2017/03)
  • Page 14: Settings

    – Deleting switching points – Connecting heating phases ( Chapter 6.2.4, page 21) – Deleting heating phases • DHW heating • Creating a new DHW program • Creating a new circulation program Table 3 Standard functions Control 8313 – 6720859552 (2017/03)
  • Page 15: Advanced Functions For Heating Circuits

    ( Chapter 5.8.1, page 18) Continuous operation Once-only cylinder – – Option of heating the DHW once, ( Chapter 5.8.2, page 19) charging although the system is in setback mode. Table 5 Advanced functions for DHW Control 8313 – 6720859552 (2017/03)
  • Page 16: Information On The Standard Functions And The Advanced Functions

    ▶ Tap symbol and select operating mode. 5.2.1 Auto In this operating mode, the room temperature is determined by the values specified in the time program. symbol shows the temperature set for the current operating mode. Control 8313 – 6720859552 (2017/03)
  • Page 17: Manual Heating Modeand Manual Setback Mode

    The holiday function must be set for every heating circuit (DHW heating) In this operating mode, the heating circuit is switched off. separately. 5.4.2 Deleting the holiday function ▶ Select the holiday period that was entered ▶ Tap symbol. Control 8313 – 6720859552 (2017/03)
  • Page 18: Party Function

    In this operating mode, you can switch or adjust individual components manually. ▶ Tap component. ▶ Change values, switch on/off etc. ▶ Tap Save. 5.7.5 The DHW function is switched off in this operating mode. Control 8313 – 6720859552 (2017/03)
  • Page 19: Once-Only Cylinder Charging

    ▶ Tap Save. To display the temperature for a switching point: ▶ Tap  symbol briefly. The actual temperature set for this switching point is displayed. The room temperature can be adjusted separately for each time program. Control 8313 – 6720859552 (2017/03)
  • Page 20: Selecting The Standard Program

    ▶ Tap symbol and select the required program from the dropdown list. 12:00 ▶ Tap Save. 0010009487-001 ▶ If required, adapt the switching points and temperatures to the Fig. 26 Shifting switching points specific lifestyle habits. Control 8313 – 6720859552 (2017/03)
  • Page 21: Creating A New Time Program

    ▶ Tap Save field. ▶ Tap Program field again ▶ Tap Program selection box. ▶ Select Family from the list. ▶ Tap Day of week selection box ▶ Select Saturday to Sunday ▶ Tap Save field. Control 8313 – 6720859552 (2017/03)
  • Page 22 DHW circulation time program ( Chapter Creating a new DHW Active time program time program, page 21). Cancel ▶ Tap Save. [10] Switching point [11] Time [12] DHW circulation pump time program on [13] DHW circulation pump time program off Control 8313 – 6720859552 (2017/03)
  • Page 23: Connectivity

    GB = Great Britain) • Password (The password must be at least 12 characters long in 0010009260-001 keeping with Bosch rules, and include at least one special character in addition to upper and lower case letters.) Fig. 31 Registration • Confirm password (When you enter the password again, it must Conditions of use exactly match the password previously entered.)
  • Page 24: Accessing The Mec Remote Portal

    [18] System ▶ Tap Send field. [19] System The new login data is sent to the stored e-mail address. ▶ Tap the symbol. The change mask opens. ▶ Make changes in the fields and confirm. Control 8313 – 6720859552 (2017/03)
  • Page 25: User Settings

    Resetting the password To reset the password: ▶ Tap Unlock/reset password field. An e-mail is sent to the stored email address. ▶ Open e-mail and click on the link provided. ▶ Assign new password and save. Control 8313 – 6720859552 (2017/03)
  • Page 26: Cleaning The Control Unit

    If more faults and service displays than can be displayed on one page exist, you can scroll through the pages via the arrows in the footer. 0010008700-001 Fig. 38 Fault display Event Occurred (date, time) Fault location Message text Control 8313 – 6720859552 (2017/03)
  • Page 27: Troubleshooting

    • The specified period before maintenance is ▶ Call service. interval expired next due has expired. ▶ Have maintenance carried out. The automatic maintenance message remains active until it is reset by an approved heating contractor. Table 7 Troubleshooting Control 8313 – 6720859552 (2017/03)
  • Page 28: Appendix

    Outside temperature Display of measured outside Substation Selection or display of temperature subsystem data. Operating mode Set the operating mode Version Shows the software versions of the user interface and the control unit Control 8313 – 6720859552 (2017/03)
  • Page 29 Display the status of a function System, system component or or a system component function is switched off. Burner starts Display number of burner Advanced functions Additional setting options for starts the heating circuit, DHW, etc. Control 8313 – 6720859552 (2017/03)
  • Page 30: 11.2.3 Explanation Of Symbols, Portal Settings

    Change the settings or system data. Mirror system data Transfer control unit view to User settings Customising the portal settings the monitor Exit portal End access to the control unit Table 11 Explanation of symbols, portal settings Control 8313 – 6720859552 (2017/03)