Configuring A Frame Relay Connection - Siemens RUGGEDCOM ROX II User Manual

Cli
Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents
Chapter 3
Device Management
3.
Configure the following parameter(s) as required:
Parameter
nomagic
on-demand
mtu { mtu }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 3.23.13

Configuring a Frame Relay Connection

To configure a frame relay connection for a T1 or E1 line, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Depending on the WAN module, navigate to either:
• For T1/E1 Lines
interface » wan » {interface} » {protocol} » channel » {number} » connection, where {interface} is the
WAN interface, {parameter} is either T1 or E1, and {number} is the channel number.
• For DDS
interface » wan » {interface} » dds » connection, where {interface} is the WAN interface, {parameter} is
either T1 or E1, and {number} is the channel number.
3.
Configure the following parameter(s) as required:
Parameter
station { station }
signal { signal }
t391 { t391 }
t392 { t392 }
142
Description
Synopsis: true or false
Default: false
Disables the Magic Number. (Valid on RX1000 only)
Synopsis: typeless
This interface is up or down on demand of link fail over.
Synopsis: An integer between 256 and 1500
Default: 1500
Maximum transmission unit (largest packet size allowed for this
interface).
Description
Synopsis: { cpe, switch }
Default: cpe
The behavior of the frame relay connection, i.e. CPE (Customer
Premises Equipment) or as a switch.
Synopsis: { ansi, lmi, q933, none }
Default: ansi
The frame relay link management protocol used.
Synopsis: An integer between 5 and 30
Default: 10
(Link Integrity Verification polling) Indicates the number of
seconds between transmission of in-channel signaling messages.
Valid for cpe.
Synopsis: An integer between 5 and 30
Default: 16
(Verification of polling cycle) Indicates the expected number of
seconds between reception of in-channel signaling messages
transmitted by cpe. Valid for Switch.
Configuring a Frame Relay Connection
RUGGEDCOM ROX II
CLI User Guide
Table of Contents
loading

This manual is also suitable for:

Rx1500Rx1512Rx1501Rx1510Rx1511

Table of Contents