Siemens RUGGEDCOM RX1500 Installation Manual

Siemens RUGGEDCOM RX1500 Installation Manual

Hide thumbs Also See for RUGGEDCOM RX1500:
Table of Contents
RUGGEDCOM RX1500
Installation Guide
12/2013
RC1053-EN-01
Preface
Introduction
Installing the Device
Communication Ports
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6
Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RX1500

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RX1500 Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 12/2013 RC1053-EN-01...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3: Table Of Contents

    RUGGEDCOM RX1500 Installation Guide Table of Contents Table of Contents Preface ........................ Alerts ..............................v Related Documents ..........................v Accessing Documentation ........................v Training .............................. vi Customer Support ..........................vi Chapter 1 Introduction ......................1.1 Feature Highlights ........................1 1.2 Ports, Controls and Indicator LEDs ....................3 Chapter 2 Installing the Device ....................
  • Page 4 RUGGEDCOM RX1500 Table of Contents Installation Guide 3.3 SFP Optic Ethernet Ports ......................21 3.3.1 Installing an SFP Optical Port ..................21 3.3.2 Removing an SFP Optical Port ..................22 3.4 WAN Modules ..........................23 3.5 Serial Ports ..........................24 3.6 Cellular Modem Modules ......................
  • Page 5: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RX1500. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 6: Training

    Siemens sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, please contact Customer Support at: Toll Free (North America): 1 866 922 7975...
  • Page 7: Introduction

    Introduction Introduction The RUGGEDCOM RX1500 is a cost-efficient, rugged Layer 3 switch and router. The RX1500’s modular and field replaceable platform allows you to select WAN, serial, and Ethernet options, making it ideally suited for electric power utilities, the industrial plant floor, and traffic control systems.
  • Page 8 Chapter 1 RUGGEDCOM RX1500 Introduction Installation Guide • Up to 8 ports Gigabit Ethernet WAN Port Options • T1/E1 (channelized) • E1 75 Ω via BNC • Cellular (HSPA/EVDO) • DDS Serial Ports • Fully compliant EIA/TIA RS485, RS422 and RS232 serial ports (software selectable) with RJ45 connectors, DNP and MODBUS •...
  • Page 9: Ports, Controls And Indicator Leds

    RUGGEDCOM RX1500 Chapter 1 Installation Guide Introduction • Input voltage ranges: 13-36 VDC and 37-72 VDC or 85-264 VAC and 88-300 VDC for worldwide operability • CSA/UL 60950-1 safety approved to 85 °C (185 °F) Section 1.2 Ports, Controls and Indicator LEDs The RX1500 features various ports, controls and indicator LEDs on the front panel for configuring and troubleshooting the device.
  • Page 10 RUGGEDCOM RX1500 Chapter 1 Installation Guide Introduction Ports, Controls and Indicator LEDs...
  • Page 11: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 12: Mounting The Device To A Rack

    Chapter 2 RUGGEDCOM RX1500 Installing the Device Installation Guide The following sections describe the various methods of mounting the device: • Section 2.1.1, “Mounting the Device to a Rack” • Section 2.1.2, “Mounting the Device on a DIN Rail” •...
  • Page 13: Mounting The Device On A Din Rail

    RUGGEDCOM RX1500 Chapter 2 Installation Guide Installing the Device Figure 2: Rack Mount Adapters 1. Rear 2. Front 3. Rack Mount Adapter If required, install adapters on the opposite side of the device to protect from vibrations. Insert the device into the rack.
  • Page 14: Mounting The Device To A Panel

    Chapter 2 RUGGEDCOM RX1500 Installing the Device Installation Guide Section 2.1.3 Mounting the Device to a Panel For panel installations, the RX1500 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 15: Installing/Removing Power Supplies

    RUGGEDCOM RX1500 Chapter 2 Installation Guide Installing the Device • For maximum redundancy in a dual power supply configuration, use two independent power sources. • Use only #16 gage copper wiring when connecting terminal blocks. • The maximum wire length between the terminal block and power source must not exceed 6 m (20 ft) for 24 V power supplies or 18 m (60 ft) for 48 V power supplies.
  • Page 16: Installing A Power Supply

    Chapter 2 RUGGEDCOM RX1500 Installing the Device Installation Guide Section 2.2.1.1 Installing a Power Supply To install a power supply, do the following: NOTE The power supplies are hot swappable. It is not necessary to disconnect power to the device before installing or removing a power supply.
  • Page 17: Connecting Ac Power

    RUGGEDCOM RX1500 Chapter 2 Installation Guide Installing the Device Figure 7: Removing a Power Supply 1. Chassis 2. Power Supply 3. Screws Install the blank power module assembly into the empy slot to prevent the ingress of dust and dirt.
  • Page 18: Connecting Dcpower

    Chapter 2 RUGGEDCOM RX1500 Installing the Device Installation Guide Figure 8: AC Terminal Block Wiring 1. Pluggable Terminal Block for HI Power Supplies 2. Screw-Type Terminal Block for HIP Power Supplies 3. Positive/Live (+/L) Terminal 4. Surge Ground Terminal 5. Negative/Neutral (-/N) Terminal Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
  • Page 19: Connecting The Failsafe Alarm Relay

    RUGGEDCOM RX1500 Chapter 2 Installation Guide Installing the Device Figure 9: DC Terminal Block Wiring 1. Pluggable Terminal Block for 24P and 48P Power Supply 2. Screw-Type Terminal Block for 24 and 48 Power Supply 3. Positive/ Live (+/L) Terminal 4.
  • Page 20: Grounding The Device

    Chapter 2 RUGGEDCOM RX1500 Installing the Device Installation Guide Figure 10: Failsafe Alarm Relay Wiring 1. Normally Open 2. Common 3. Normally Closed Section 2.4 Grounding the Device The RX1500 chassis ground terminal uses a #10-32 screw. It is recommended to terminate the ground connection with a #10 ring lug and torque it to 3.4 N·m (30 lbf·in).
  • Page 21: Cabling Recommendations

    Web interfaces via the device's IP address. For more information about available ports, refer to Chapter 3, Communication Ports. Section 2.6 Cabling Recommendations Siemens recommends using SIMATIC NET industrial Ethernet shielded cables for all Ethernet ports. Refer to the following sections for further recommendations and considerations: Cabling Recommendations...
  • Page 22: Protection On Twisted-Pair Data Ports

    Section 2.6.1 Protection On Twisted-Pair Data Ports Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
  • Page 23: Communication Ports

    RUGGEDCOM RX1500 Chapter 3 Installation Guide Communication Ports Communication Ports The RX1500 can be equipped with various types of communication ports to enhance its abilities and performance. Each set of communication ports is part of a field replaceable module that makes switching ports fast and easy.
  • Page 24 Chapter 3 RUGGEDCOM RX1500 Communication Ports Installation Guide CAUTION! Contamination hazard – risk of damage to equipment. M12 modules are shipped with internal O-rings and dust caps to prevent the ingress of dirt and debris that may damage the port. Make sure the O- rings and dust caps are installed on all unused M12 ports.
  • Page 25 RUGGEDCOM RX1500 Chapter 3 Installation Guide Communication Ports State Description No link detected The following are the pin-out descriptions for the RJ45 and M12 connectors: Name Description 10/100Base-TX 1000Base-TX BI_DB+ Receive Data+ or Bi-Directional BI_DB- Receive Data- Figure 25: RJ45 Ethernet Port Pin Configuration...
  • Page 26: Fiber Optic Ethernet Ports

    Chapter 3 RUGGEDCOM RX1500 Communication Ports Installation Guide 10/100/1000Base-Tx Signal 10/100Base-Tx Signal Figure 28: 4-Pin M12 D-Coded Ethernet Port Pin Configuration Terminated at GND (Ground) For specifications on the available copper Ethernet ports, refer to Section 4.4, “Copper Ethernet Port Specifications”.
  • Page 27: Sfp Optic Ethernet Ports

    To install an SFP optical port, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been properly assessed.
  • Page 28: Removing An Sfp Optical Port

    Chapter 3 RUGGEDCOM RX1500 Communication Ports Installation Guide Insert the port into the module and swing the bail-latch up to lock it in place. Figure 34: Installing an SFP Optical Port (Typical) 1. SFP Optical Port 2. Metal Bail-Latch Remove the dust cover from the port.
  • Page 29: Wan Modules

    RUGGEDCOM RX1500 Chapter 3 Installation Guide Communication Ports Section 3.4 WAN Modules The RX1500 supports the following WAN (Wide Area Network) line modules: NOTE • Only one T1/E1 WAN module may be used per router. • The TC1, TC2 and TC4 WAN modules comply with Part 68 of the FCC rules and requirements adopted by ACTA.
  • Page 30: Serial Ports

    Chapter 3 RUGGEDCOM RX1500 Communication Ports Installation Guide Figure 41: RJ45 T1/E1 Pin Configuration 1. RTIP 2. TTIP 3. Chassis Name Description RRING Receive Negative RTIP Receive Positive Reserved (Do Not Connect) TRING Transmit Negative Figure 42: RJ45C T1/E1 Pin Configuration...
  • Page 31: Cellular Modem Modules

    RUGGEDCOM RX1500 Chapter 3 Installation Guide Communication Ports RS232 Mode RS485 Mode RS422 Mode RX- (Receive Negative) Reserved (Do Not Connect) Common (Isolated) Ground Figure 43: Serial RJ45 Port RX (Receive) RX+ (Receive Negative) TX (Transmit) TX/RX+ TX+ (Transmit (Transmit/...
  • Page 32: Supported Frequency Bands

    Chapter 3 RUGGEDCOM RX1500 Communication Ports Installation Guide Order Code Description 1 Port Cell Modem GSM,EDGE,HSPA+ 1 Port Cell Modem EVDO Rev.A Verizon Wireless Figure 44: W11 and W21 Cellular Modems 1. Main Antenna SMA Connector 2. Receive Diversity Antenna...
  • Page 33: Installing Sim Cards For Gsm, Edge And Hspa+ Cellular Modems

    RUGGEDCOM RX1500 Chapter 3 Installation Guide Communication Ports Frequency Range Maximum RX Diversity Band Allowable Support Tx (MHz) VSWR Rx (MHz) VSWR Gain (dBi) Band V 824-849 < 2.5:1 869-894 < 3.5:1 ü WCDMA 850 Band VI 830-840 < 2.5:1 875-885 <...
  • Page 34: Dds (Digital Data Services) Modules

    Chapter 3 RUGGEDCOM RX1500 Communication Ports Installation Guide Figure 47: W12, W22, W32 Cellular Modem 1. SIM Card Cage 2 2. SIM Card Cage 1 Open SIM card cage 1 by sliding the silver catch towards the antenna connectors and flip the cage up.
  • Page 35: Ruggedcom Ape Module

    RUGGEDCOM RX1500 Chapter 3 Installation Guide Communication Ports The 56 kbps DDS port is compatible with Bellcore standards. Each DDS module features a single 56/64 kbps DDS line interface with a standard RJ45 receptacle. Each RJ45port features a RX and TX LED that indicates the state of the port.
  • Page 36: Installing/Removing Modules

    Chapter 3 RUGGEDCOM RX1500 Communication Ports Installation Guide For specifications, refer to Section 4.7, “RUGGEDCOM APE Specifications”. Section 3.9 Installing/Removing Modules The following sections describe how to install and remove modules: • Section 3.9.1, “Installing a Module” • Section 3.9.2, “Removing a Module”...
  • Page 37: Removing A Module

    RUGGEDCOM RX1500 Chapter 3 Installation Guide Communication Ports Section 3.9.2 Removing a Module Once a module is removed, all the features associated with the module are hidden or disabled in the operating system. To remove a module, do the following: Make sure power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
  • Page 38 Chapter 3 RUGGEDCOM RX1500 Communication Ports Installation Guide • The shield should be connected to earth ground at a single point to avoid loop currents. • The twisted pair should be terminated at each end of the chain. The following shows the recommended RS485 wiring.
  • Page 39: Technical Specifications

    RUGGEDCOM RX1500 Chapter 4 Installation Guide Technical Specifications Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section 4.1, “Power Supply Specifications” • Section 4.2, “Failsafe Relay Specifications” • Section 4.3, “Copper Serial Port Specifications”...
  • Page 40: Copper Serial Port Specifications

    Chapter 4 RUGGEDCOM RX1500 Technical Specifications Installation Guide Maximum Switching Voltage Rated Switching Current Isolation 250 VAC 6.25 A Dielectric test voltage (1 minute) between coil and contacts. Section 4.3 Copper Serial Port Specifications Order Code Baud Rate Connector Isolation...
  • Page 41: Fiber Optic Ethernet Port Specifications

    RUGGEDCOM RX1500 Chapter 4 Installation Guide Technical Specifications Section 4.5 Fiber Optic Ethernet Port Specifications The following sections detail fiber optic specifications for ports that can be equipped on the RX1500 . The user determines the type of optics at the time of ordering, and can determine the ports installed on a particular unit by reading the factory data file via the ROX II user interface.
  • Page 42: Gigabit Ethernet (1 Gbps) Optical Specifications

    NOTE • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 43: Operating Environment

    RUGGEDCOM RX1500 Chapter 4 Installation Guide Technical Specifications Cable Tx λ Distance Power Order Connector Tx min Tx max Mode Type (typ.) Sensitivity Saturation (typ.) Budget Code Type (dBm) (dBm) (μm) (nm) (dBm) (dBm) (km) (dB) FG03 9/125 1310 -9.5 11.5...
  • Page 44: Mechanical Specifications

    Chapter 4 RUGGEDCOM RX1500 Technical Specifications Installation Guide Feature APE1402 APE1402W7 APE1404 APE1404W7 APE1404CPK LED Indications Power and Disk Contols Momentary contact reset button Temperature Range -40 to 70 °C (-40 to 158 °F) Power Requirements 12 W with no USB load, 14.5 W with full USB load Software Platform Debian Linux®...
  • Page 45: Dimension Drawings

    RUGGEDCOM RX1500 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 440.9 Figure 54: Overall Dimensions...
  • Page 46 Chapter 5 RUGGEDCOM RX1500 Dimension Drawings Installation Guide 11.7 463.8 21.1 Figure 55: Rack Mount Dimensions 479.0 11.7 21.1 489.2 Figure 56: Panel and Din Rail Mount Dimensions...
  • Page 47: Certification

    RUGGEDCOM RX1500 Chapter 6 Installation Guide Certification Certification The RX1500 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. • Section 6.1, “Agency Approvals” • Section 6.2, “FCC Compliance”...
  • Page 48: Fcc Compliance

    Chapter 6 RUGGEDCOM RX1500 Certification Installation Guide Agency Standards Comments Cellular LM Models RX1500PN-W11-XX RX1500PN-W12-XX RX1500PN-W32-XX FCC ID for W11 and W12: N7NMC8705 FCC ID for W32: N7NMC8705/N7N-MC5728 IC ID for W11 and W12: 2417C-MC8705 IC ID for W32: 2417C- MC8705/2417C-MC5728 Section 6.2...
  • Page 49 RUGGEDCOM RX1500 Chapter 6 Installation Guide Certification Severity Test Description Test Levels Levels IEC 61000-4-5 Surge Signal ports +/- 4 kV line-to-earth, +/- 2 kV line-to-line D.C. Power ports +/- 2 kV line-to-earth, +/- 1 kV line-to-line A.C. Power ports...
  • Page 50: Environmental Type Tests

    Chapter 6 RUGGEDCOM RX1500 Certification Installation Guide IEEE 1613 (C37.90.x) EMI Immunity Type Tests NOTE The RX1500 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Test Description Test Levels IEEE C37.90.3 Enclosure Contact...