Installation, Operation & Maintenance
Instructions
Please leave this instruction booklet with the home owner as it contains
important guarantee, maintenance and safety information
Read this manual carefully before commencing installation.
This manual covers the following products:
PH 45 TS S
Pt. No. 46628
PH 45 TS S
Pt. No. 46632
PH 45 TS S
Pt. No. 46629
CE compliant product
Table of Contents
loading

Summary of Contents for Stuart Turner PH 45 TS S

  • Page 1 Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information Read this manual carefully before commencing installation. This manual covers the following products: PH 45 TS S PH 45 TS S Pt. No. 46628 Pt. No. 46629 PH 45 TS S Pt.
  • Page 2: Table Of Contents

    WARNING AGAINST MISUSE This pump set must not be used for any other application without the written consent of Stuart Turner Limited. In particular, it must not be connected directly to the mains water supply, or used outside the conditions specified in the limits of application.
  • Page 3: Product Description

    *Variations of rating and enclosure details can be found in the technical specification section. Pump All models are close coupled to motor. PH 45 TS S are of single stage, peripheral design, with vertical suction and discharge ports. Standard pump materials of construction of major wetted parts are as follows: - Model Part No.
  • Page 4: Limits Of Application

    G¾ M G¾ M l/min & above Stuart Turner reserve the right to amend the specification in line with its policy of continuous development of its products. Note: For information on other voltages/frequencies which are not shown, consult any supplementary instruction sheet supplied, or the rating label attached to the pump.
  • Page 5 Do not allow plastic pump parts to come into contact with oil or  cellulose based paints, paint thinners or strippers, acid based descalents or aggressive cleaning agents. Do not introduce solder flux to pumps or pump parts manufactured  from plastic.
  • Page 6: Electrical Installation

    (outlet) pipework from the pump. INLET OUTLET Fig. 1 PH 45 TS S ELECTRICAL INSTALLATION WARNINGS: The electrical installation must be carried out in accordance with the ...
  • Page 7 Earthing This appliance must be earthed via the supply cord, which must be correctly connected to the earth point located in the terminal box. Metallic pipework must have supplementary earth bonding where the continuity has been broken by flexible hoses or plastic components. Adjacent suction and delivery pipes should be fitted with earthing clamps to BS 951 and connected with earthing wire size 4 mm²...
  • Page 8 If the supply cord is to be changed or is damaged, it must be replaced with a special cord assembly available from Stuart Turner or one of their approved repairers. On disassembly note the cord retention and routing system. Re-assemble to the same pattern.
  • Page 9 Cable Gland & Supply Cord Fitting Instructions (Single phase range) The cable gland assembly Fig. 5 (items 1 & 2) provides the necessary protection against ingress of solid objects and moisture as well as providing cable retention. Assembly instructions are as follows: - 1.
  • Page 10: Noise

    Wiring Diagrams The internal wiring within the terminal box are routed and secured to ensure compliance with the electrical standard EN 60335-1. It is essential that any disturbance of this internal wiring is avoided and the factory routing and securing of all internal wiring is always maintained. MAIN WINDING THERMO...
  • Page 11 Liquid Supply Always ensure that liquid storage capacity is adequate to meet the demand. Ensure the pump chamber is full of liquid before starting the pump. Failure to do this could result in seal damage. To ensure dry running does not occur the pumps must be primed as described in the priming section.
  • Page 12 6. Variable Performance: PH 45 TS S pumps are designed to allow the performance of the pump to be modified by turning the mounting plate through approximately 30º. To change the performance of the pump, use the following procedure:- 1) The pump is supplied set in the maximum performance position (Fig. 9).
  • Page 13: Maintenance

    MAINTENANCE WARNINGS: Care should be taken to protect the pump from frost and  freezing. Pump Location  If possible site the pump in a location where in the unlikely event of a liquid leak, any spillage is contained or routed to avoid electrics or areas sensitive to water damage.
  • Page 14: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE Symptoms Probable Cause Recommended Action Pump will not start. Electrical supply. Check power to motor. Check the circuit breaker is set. Check the correct fuse is being used. Starter thermal Check overload in starter (if applicable). overload tripped. Investigate cause of problem.
  • Page 15 Trading Standards Department or Citizen’s Advice Bureau. In the event of a claim please telephone Stuart Turner Limited on 0844 980 0097 or return your pump and flexible hoses with accessories removed, plugs, pipes etc. If you have any doubt about removing a pump, please consult a professional.
  • Page 16 Signed ......... Stuart Turner are an approved company to BS EN ISO 9001:2000...