Stuart Turner PH 45 TS S Installation, Operation & Maintenance Instructions Manual

Stuart Turner PH 45 TS S Installation, Operation & Maintenance Instructions Manual

For positive head applications only 50 hz

Quick Links

Installation, Operation & Maintenance
Instructions
Please leave this instruction booklet with the owner as it contains
important guarantee, maintenance and safety information
Read this manual carefully before commencing installation.
This manual covers the following products:
PH 45 TS S
Pt. No. 46628
FOR POSITIVE HEAD APPLICATIONS ONLY
50 Hz
PH 45 TS S
Pt. No. 46629
CE compliant product
Table of Contents
loading

Summary of Contents for Stuart Turner PH 45 TS S

  • Page 1 Please leave this instruction booklet with the owner as it contains important guarantee, maintenance and safety information Read this manual carefully before commencing installation. This manual covers the following products: PH 45 TS S PH 45 TS S Pt. No. 46628 Pt. No. 46629...
  • Page 2: Table Of Contents

    The PH stainless steel range of peripheral pumps are designed to pump clean fresh water. Other clean, non aggressive, non explosive liquids with similar characteristics to water may be pumped. Consult Stuart Turner for such applications. The pumps can be used for pressure boosting, fluid transfer and distribution. They are suitable for flooded suction applications.
  • Page 3: Checklist

    IMPORTANT: With the pump removed from its packaging check for any damage prior to installation. If any damage is found contact Stuart Turner Ltd within 24 hours of receipt. Fig. 1 Your product may vary slightly from the picture above.
  • Page 4: Important Facts - Read Before Commencing Installation

    F. Variable performance 1.22 PH 45 TS S pumps are designed to allow the performance of the pump to be modified by turning the mounting plate through approximately 30º. To change the performance of the pump, use the following procedure:- 1) The pump is supplied set in the maximum performance position (Fig.
  • Page 5 Ensuring the ‘O’-ring seal is not trapped between the faces, re-tighten the four M6 retaining screws. This must be done evenly to ensure the correct function of the pump. Tighten to 2.6 Nm, do not over tighten. Repeat priming procedure detailed in Section 4 before restarting the pump. Check pump and pipework for leaks whilst pump is running and stationary before leaving the installation unattended.
  • Page 6: Location

    2 LOCATION - GENERAL 2.11 Access: For emergencies and maintenance the pump must be easily accessible. 2.12 Protection: The pump must be located in a dry position, frost free and protected from freezing. 2.13 Ventilation: Ensure an adequate air flow to cool the pump. Separate the pump from other appliances that generate heat.
  • Page 7: Electrical Installation

    3 ELECTRICAL INSTALLATION / EARTHING 3.11 Regulations: The electrical installation must be carried out in accordance with the current local regulations by a qualified person. 3.12 Safety: In the interests of electrical safety a 30 mA residual current device (R.C.D. not supplied) should be installed in the supply circuit. This may be part of a consumer unit or a separate unit.
  • Page 8 3.18 Cable Gland & Supply Cord Fitting Instructions (Single phase range) The cable gland assembly Fig. 9 (items 1 & 2) provides the necessary protection against ingress of solid objects and moisture as well as providing cable retention. Assembly instructions are as follows: - 1.
  • Page 9 3.19 Wiring diagram: MAIN WINDING THERMOTRIP CAPACITOR START WINDING TERMINAL BLOCK Fig. 10 3.20 Fuse: All models should use 5 Amp fuse. 3.21 Supply cord replacement: The internal wiring within the terminal box is routed and secured to ensure compliance with the electrical standard EN 60335-1.
  • Page 10: Plumbing

    This product is maintenance free for its life, however it is a mechanical product and will eventually show signs of wear. Spare parts are available, for more information phone the Stuart Turner PumpAssist team on +44 (0) 800 31 969 80. - 10 -...
  • Page 11: Technical Specification

    166 mm Weight (including fittings) 6.3 Kg Stuart Turner reserve the right to amend the specification in line with its policy of continuous development of its products. *Note: The maximum pressure that can be applied to the pump under any installation conditions.
  • Page 12: Trouble Shooting

    Check fuse (see fuse section). Check circuit breaker is set. Check wiring connections. Pump jammed. If motor ‘Buzzes’ switch off power and contact Stuart Turner. Integral motor thermotrip Wait for thermotrip to auto-reset and check that duty point activated. and run time is within specification.
  • Page 13: Guarantee

    Proof of purchase should accompany the returned unit to avoid delay in investigation and dealing with your claim. You should obtain appropriate insurance cover for any loss or damage which is not covered by Stuart Turner Ltd in this provision. Please record here for your records. TYPE NO.
  • Page 14 NOTES - 14 -...
  • Page 15 NOTES - 15 -...
  • Page 16: Declaration Of Conformity

    Signed ......... Stuart Turner are an approved company to BS EN ISO 9001:2008...