Specifications; Gases Detected - Honeywell 301W User Manual

Wireless gas detection device
Table of Contents
Available languages

Available languages

Power:
Alarm levels:
Detection range:
Operating Pressure range:
Communication:
Communication range:
Visual Indicators:
Dimensions:
Certification:

Gases Detected

Operating
Gas
Temperature
-20°C to 50°C
CO
(-4 °F to 122 °F)
-20°C to 50°C
NO
2
(-4 °F to 122 °F)
-20°C to 50°C
O
2
(-4 °F to 122 °F)
511398
5/07

Specifications

One 3.6 V, 19 AH battery (supplied by sensor
module)
Gas
Alarm A
CO
25 ppm
NO2
0.72 ppm
O2
19.5% vol
CO:
0 to 250 ppm
NO2: 0 to 6 ppm
O2:
0 to 25%
95 to 110 kPa
2.4 GHz ISM wireless
30 m indoor
2 LEDs (with pushbutton interfaces)
22.5 x 10 x 5.7cm
8.85" x 4" x 2.25"
FCC ID: U5C301W-1
IC: 573P-301W1
Operating
Humidity
15 - 95% non-
condensing
15 - 95% non-
condensing
15 - 95% non-
condensing
301W User Manual
Honeywell
Alarm B
200 ppm
2.0 ppm
22.0% vol
Accuracy
Resolution
at 25ºC
± 10 ppm 7 ppm
± 0.2 ppm 0.05 ppm
± 0.2 %
0.1%
Specifications
Gases Detected
Alarm C
225 ppm
5.4 ppm
22.5% vo
T90
<30 sec
<30 sec
<15 sec
37

Chapters

Table of Contents
loading

Table of Contents