Specifications and Reference Data
Table A-17:
Rosemount 5408 and 5408:SIS Spare Parts List - Antenna
(9)
Hydrostatic testing
Q5
Hydrostatic Testing, including certificate
Material traceability certification
Q8
Material Traceability Certification per EN 10204 3.1 (2.1 for non-metallic)
(11)
Hygienic certification
QA
Certificate of compliance to 3-A
(12)
Materials certification
Q15
NACE Material Recommendation per NACE MR0175/ISO 15156
Q25
NACE Material Recommendation per ANSI/NACE MR0103/ISO 17495-1
Q35
NACE Material Recommendation per NACE MR0175/ISO 15156 and ANSI/NACE MR0103/ISO 17495-1
Welding procedure qualification record documentation
Q66
Welding Procedure Qualification Record (WPQR)
Q67
Welder Performance Qualification (WPQ)
Q68
Welding Procedure Specification (WPS)
Q79
WPQR/WPQ/WPS
Dye penetration test certificate
Q73
Certificate of Liquid Penetrant Inspection
Positive material identification certificate
Q76
Positive Material Identification Certificate of Conformance
Extended product warranty
WR3
3-year Limited Warranty
WR5
5-year Limited Warranty
Specials (see
Section
A.3.2)
PXXXX
Custom Engineered Solutions beyond standard model codes. Consult factory for details.
Typical model number: 5408 Z 9 Z Z Z Z NA 1 R 3 AB CAB 3
(1) Type A flat face for EN 1092-1 flanges.
(2) Type B1 raised face for EN 1092-1 flanges.
(3) Pressure limit is derated for process temperatures above 100 °F (38 °C), see
(4) Refer to
Figure A-6
for pressure/temperature ratings of Tri-Clamp connection.
(5) Option code PC1 is for cone antennas only, and requires matching flange and antenna sizes. Note that all parabolic antennas come
with an integrated air purge connection.
(6) A minimum gasket thickness of 0.125 in. (3.2 mm) is required for flanges with protective plate design.
(7) Only applies to flanged process connections with welded construction or protective plate design; only applicable to cone antennas (see
Table A-12
and
Table
A-13).
(8) Only available with ASME B16.5 flange connections, and materials of construction codes 1 and 7.
(9) Hydrostatic testing is only available for cone antennas and process seal antennas with flanged process connections.
(10) Certificate includes all pressure retaining and wetted parts.
184
(10)
(7)
(7)
(continued)
Figure A-4
for details.