GE B30 Communications Manual page 501

Universal relay family
Hide thumbs Also See for B30:
Table of Contents
CHAPTER 4: DNP COMMUNICATION
Object
Object
Variation
Description
no.
no.
20
0
Binary Counter
(Variation 0 is used to request
default variation)
1
32-Bit Binary Counter
20
2
16-Bit Binary Counter
cont'd
5
32-Bit Binary Counter without Flag 1 (read)
6
16-Bit Binary Counter without Flag 1 (read)
Note 1: A default variation refers to the variation responded when variation 0 is requested and/or in class 0, 1, 2, or 3 scans. The default
variations for object types 1, 2, 20, 21, 22, 23, 30, and 32 are selected via relay settings. See the Communications section in Chapter 5
of the Instruction Manual for details. This optimizes the class 0 poll data size.
Note 2: For static (non-change-event) objects, qualifiers 17 or 28 are only responded when a request is sent with qualifiers 17 or 28,
respectively. Otherwise, static object requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded with qualifiers 00 or 01 (for
change-event objects, qualifiers 17 or 28 are always responded.)
Note 3: Cold restarts are implemented the same as warm restarts, meaning that the UR is not restarted, but the DNP process is restarted.
UR FAMILY – COMMUNICATIONS GUIDE
Request
Function codes
Qualifier codes
(dec)
(hex)
1 (read)
00, 01(start-stop)
7 (freeze)
06(no range, or all)
8 (freeze noack)
07, 08(limited
9 (freeze clear)
quantity)
10 (frz. cl. noack)
17, 28(index)
22 (assign class)
1 (read)
00, 01 (start-stop)
7 (freeze)
06 (no range, or all)
8 (freeze noack)
07, 08 (limited
9 (freeze clear)
quantity)
10 (frz. cl. noack)
17, 28 (index)
22 (assign class)
1 (read)
00, 01 (start-stop)
7 (freeze)
06 (no range, or all)
8 (freeze noack)
07, 08 (limited
9 (freeze clear)
quantity)
10 (frz. cl. noack)
17, 28 (index)
22 (assign class)
00, 01 (start-stop)
7 (freeze)
06 (no range, or all)
8 (freeze noack)
07, 08 (limited
9 (freeze clear)
quantity)
10 (frz. cl. noack)
17, 28 (index)
22 (assign class)
00, 01 (start-stop)
7 (freeze)
06 (no range, or all)
8 (freeze noack)
07, 08 (limited
9 (freeze clear)
quantity)
10 (frz. cl. noack)
17, 28 (index)
22 (assign class)
DEVICE PROFILE DOCUMENT
Response
Function codes
Qualifier codes
(dec)
(hex)
129 (response)
00, 01 (start-stop)
17, 28 (index)
(see Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index)
(see Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index)
(see Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index)
(see Note 2)
4
4-5

Hide quick links:

Table of Contents
loading

Table of Contents