GE B30 Communications Manual page 365

Universal relay family
Hide thumbs Also See for B30:
Table of Contents
CHAPTER 3: IEC 61850 COMMUNICATION
LNName: CapCtlGAPC#
data obj. data attribute
Type
InRef24
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef25
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef26
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef27
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef28
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef29
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef30
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
BlkRef1
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef31
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
3.5.3.10 Cold load pickup (Cold)
This element is instantiated in the following products: F35, F60.
Table 3-145: Cold load pickup data objects
LNName: ColdFXUT#
data obj. data attribute
Type
Op
ACT
general
BOOLEAN
StrVal
ASG
setMag
AnalogueValue
setMag.f
FLOAT32
units
Unit
units.SIUnit
ENUMERATED
units.multiplier
ENUMERATED
BlkRef1
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef1
ORG
setSrcRef
ObjectReference SP
UR FAMILY – COMMUNICATIONS GUIDE
LDevice inst: Ctrl
UR element: Capacitor control element #
FC UR Name
CAP # LOCAL OPEN setting
CAP # AUTO OPEN setting
CAP # BKR OPEN 52b setting
CAP # REMOTE CLOSE setting
CAP # LOCAL CLOSE setting
CAP # AUTO CLOSE setting
CAP # BKR CLSD 52a setting
CAP # BKR CLOSE BLK
CAP # CLS OVERRIDE setting
LDevice inst: Ctrl
UR element: Cold Load Pickup # element
FC UR Name
ST
COLD LOAD # OP
SP
CF
COLD LOAD # BLK.
COLD LOAD # INIT.
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Description
CAP # LOCAL OPEN setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
CAP # AUTO OPEN setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
CAP # BKR OPEN 52b setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
CAP # REMOTE CLOSE setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
CAP # LOCAL CLOSE setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
CAP # AUTO CLOSE setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
CAP # BKR CLSD 52a setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
CAP # BKR CLOSE BLK setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
CAP # CLS OVERRIDE setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
Description
COLD LOAD # OP operand
Start level of the current, which is fixed at
2% of Nominal CT (0.02 pu), and it is non-
configurable read only value
0.02
1, the code for dimensionless
0, the code for a multiplier of 1
COLD LOAD # BLK setting
reference to the data attribute to input
source GoCB of input if via GOOSE
COLD LOAD # INIT setting
reference to the data attribute to input
R/W/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
3
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R/W/C
R
R
R
R
R
R
R
R
R
R/C
R/C
R
R/C
3-127

Hide quick links:

Table of Contents
loading

Table of Contents