Technical Data; Drive Technical Data - Emerson unidrive m Installation Manual

Universal variable speed ac drive modular solutions for induction and permanent magnet motors model sizes 9 to 11
Hide thumbs Also See for unidrive m:
Table of Contents
Safety information
Introduction
7

Technical data

7.1

Drive technical data

7.1.1
Power and current ratings (Derating for switching frequency and temperature)
For a full explanation of 'Normal Duty' and 'Heavy Duty' refer to section 3.1 Ratings on page 16.
5 % derating should be applied when paralleling two or more inverters.
Table 7-1 Maximum permissible continuous output current @ 40 °C (104 °F) ambient
Nominal
Maximum permissible continuous output current
Model
rating
2
kW
hp
kHz
200 V
09201760
55
75
09202190
75
100
10202830
90
125
10203000
110
150
400 V
09402000
110
150
09402240
132
200
266
10402700
160
250
10403200
200
300
11403770
225
350
11404170
250
400
487
11404640
280
400
507
575 V
09501040
110
125
09501310
110
150
10501520
130
200
10501900
150
200
11502000
185
250
11502540
225
300
288
11502850
250
350
315
690 V
09601040
110
150
09601310
132
175
10601500
160
200
10601780
185
250
11602100
200
250
11602380
250
300
275
11602630
280
400
305
Unidrive M / Unidrive HS Modular Installation Guide
Issue Number: 5
Product information
configuration
Normal Duty
(A) for the following switching frequencies
3
4
6
8
kHz
kHz
kHz
kHz
216
184
266
258
218
184
325
313
266
360
313
266
221
192
159
255
231
192
160
320
285
238
361
339
285
238
437
415
336
272
460
415
336
272
460
415
336
272
125
101
150
126
100
200
168
126
100
200
152
116
248
220
265
220
265
220
125
100
155
126
100
172
169
126
100
197
154
114
225
220
265
220
265
220
System
Mechanical
Installation
Nominal
rating
12
16
kW
hp
kHz
kHz
128
93
45
60
128
93
55
75
194
144
75
100
194
144
90
125
108
77
90
150
109
77
110
150
173
124
132
200
173
126
160
250
185
300
200
350
250
400
71
54
75
100
70
54
90
125
70
54
110
150
76
54
132
200
150
200
185
250
225
300
71
54
90
125
71
54
110
150
71
55
132
175
75
55
160
200
185
250
200
250
250
300
Electrical
Technical data
Installation
Heavy Duty
Maximum permissible continuous output current (A)
for the following switching frequencies
2
3
4
6
kHz
kHz
kHz
kHz
176
219
212
180
283
264
300
264
200
180
157
224
211
190
157
270
237
320
307
282
237
377
372
296
417
415
372
296
464
415
372
296
104
131
106
152
138
106
190
186
137
200
184
254
221
184
285
221
184
104
131
105
150
138
105
178
137
210
184
238
221
184
263
221
184
UL Information
8
12
16
kHz
kHz
kHz
153
110
81
153
110
81
228
170
127
228
171
129
130
92
65
130
92
65
200
147
108
202
147
109
245
245
245
85
61
47
85
61
47
85
61
47
106
70
51
85
61
47
85
62
47
86
62
47
105
69
52
133