ABB Endura AZ30 series Programming Manual page 2

Integral probe and remote transmitter combustion oxygen monitor
Show thumbs Also See for Endura AZ30 series:
Table of Contents
Refer to Section 6.4.1, page 37
Menu
1
Easy Setup
Exit
Select
Easy Setup
1
Easy Setup
Language
THermocouple Type
Thermocouple Type
English
Next
Edit
Next
2
Easy Setup
Easy Setup
Instrument Tag
Temperature Units
xxx 123
Next
Edit
Next
3
Easy Setup
Easy Setup
Date Format
Factory Cal. Offset
YYYY-MM-DD
Next
Edit
Next
Easy Setup
4
Easy Setup
Time & Date
Factory Cal. Factor
11:11:11
Next
Edit
Next
Easy Setup
5
Easy Setup
Probe Type
New Probe/Cell Fitted
AZ200 & Remote Tx
Next
Edit
Next
6
Easy Setup
Cable Length
10 m
Next
Edit
Easy Setup
7
Autocal Hardware
Remote
Next
Edit
*xxx
Displayed as: Daily/
8
8
Easy Setup
Weekly/Monthly according
%O2 Range Hi
to selection at Frequency
25.00 %O2
25.00 %O2
option
Next
Next
Edit
Edit
Easy Setup
9
%O2 Range Lo
0.25 %O2
0.25 %O2
Next
Edit
Refer to Section 6.4.2, page 40
Menu
Calibrate
Exit
Select
10
Calibrate
Sensor Cal.
Type K
Type K
Test Gases
Oxygen Hold
Edit
AutoCal Hardware
Scheduled Cal.
Cal. Diagnostics
11
Back
Select
°C
1
Sensor Cal.
Edit
Edit
1-Pt AutoCal
2-Pt AutoCal
12
Manual Cal – Offset
Manual Cal – Factor
1.00 mV
Manual Cal – 2-Pt
Restore Defaults
Edit
Edit
Back
13
Test Gases
1.000
Test Gas 1 Type
Edit
Test Gas 1 Value
Test Gas 2 Type
Test Gas 2 Value
Back
Oxygen Hold
OK
Action
Preset Value
Back
AutoCal Hardware
Hardware Type
Test Gas Delay Time
Test Gas Detection
Valve Manual Control
Back
Interval
2
Scheduled Cal.
Type
Frequency
*Weekly Interval
Time of Next Cal
Sequence
Cal. Error Limit
Back
Cal. Diagnostics
Cal. Overview Diag.
Cal. Limits Diag.
Cell Diagnostics
Back
Refer to Section 6.4.3, page 48
Menu
2
3
Diagnostics
Exit
Select
Diagnostics
Diagnostics Log
Performance Log
Back
Select
Diagnostics Log
Diagnostics History
Clear History
Back
Select
Performance Log
Performance History
Clear History
Back
Select
Select
Select
Select
Select
Select
Refer to Section 6.4.4, page 49
Menu
4
Device Setup
Exit
Select
Device Setup
Instrument Tag
Probe type
Cable Length
Oxygen Setup
Temp. Setup
Security Setup
Reset Fact. Settings
Reset Temp.Trip.
Back
Select
Instrument Tag
xxxxxxxxxxx
Back
Edit
Probe type
Probe Type
AZ200 & Remote Tx
Back
Edit
Cable Length
Cable Length
10 m
Back
Edit
Oxygen Setup
%O2 Range Hi
%O2 Range Lo
Filter Time
Pressure Comp.
Back
Select
Temp. Setup
Thermocouple Type
Temperature Units
Back
Select
Security Setup
Standard Password
Advanced Password
Back
Select
3
Reset Fact. Settings
Key:
1
1-Pt and 2-Pt AutoCal options
OK
Back
displayed only if AutoCal hardware is
fitted.
Reset Temp. Trip
2
Not displayed when Autocal
Hardware/Hardware Type is set to
OK
Back
None.
3
Displayed only at Advanced level
access.
Menu
5
Display
Display
Exit
Select
See inside back
cover