Input Data (Continued)
Item
No.
07
Trunk-to-Trunk Transfer Release Warning
Tone
Time starts when a trunk begins talking with
another trunk (for example: trunk-to-trunk
transfer, outgoing from trunk, Tandem
Trunking).
When this time expires, a warning tone is heard.
If Program 24-02-10 is set, the conversation
disconnects after time expires. This time is set
again when the external digit timer expires. One
of the trunks used must be an analog trunk (or
leased line).
08
Delayed Transfer Time for all Department
Groups
09
Two B-Channel Transfer Retry Timer
10
Disconnect Trunk-to-Trunk
11
No Answer Step Transfer
12
No Answer Trunk-to-Trunk Transfer
13
Hook Flash Sending Timer When the System
Answers Automatically
Time before sending the hook flash for Call
Forward Centrex.
15
SIP Out of Range Timer
When not receiving any response within this
timer setting, system determines SIP terminal is
out of range. When set to 0, timer is invalid.
Conditions
None
Feature Cross Reference
Transfer
2-396
Item
Input Data
Default
0~64800 (sec)
1800
0~64800 (sec)
10
0~64800 (sec)
10
0~64800 (sec)
0
0~64800 (sec)
10
0~64800 (sec)
0
0~64800 (sec)
2
0~30 (sec)
4
Issue 4.0
Related
Program
14-01-25
20-28-01
20-28-02
20-28-03
24-02-10
11-11-28
11-11-29
15-07-59
10-03-16
(PRI)
14-01-25
20-28-01
20-28-02
20-28-03
24-02-07
14-01-26
14-01-26