Table 6-2 Functions in Pr mm.000
Value
Save parameters when Under Voltage Active (Pr 10.016) is not active and Low Under Voltage Threshold Select mode
1000
(Pr 06.067 = Off) is not active.
1001
Save parameter under all conditions
1070
Reset all option modules
1233
Load standard (50 Hz) defaults
1234
Load standard (50 Hz) defaults to all menus except option module menus (i.e 15 to 20 and 24 to 28)
1244
Load US (60 Hz) defaults
1245
Load US (60 Hz) defaults to all menus except option module menus (i.e 15 to 20 and 24 to 28)
1253
Change drive mode and load standard (50 Hz) defaults
1254
Change drive mode and load US (60 Hz) defaults
1255
Change drive mode and load standard (50 Hz) defaults except for menus 15 to 20 and 24 to 28
1256
Change drive mode and load US (60 Hz) defaults except for menus 15 to 20 and 24 to 28
1299
Reset {Stored HF} trip.
2001*
Create a boot file on a non-volatile media card based on the present drive parameters including all Menu 20 parameters
4yyy*
NV media card: Transfer the drive parameters to parameter file xxx
5yyy*
NV media card: Transfer the onboard user program to onboard user program file xxx
NV media card: Load the drive parameters from parameter file xxx or the onboard user program from onboard user
6yyy*
program file xxx
7yyy*
NV media card: Erase file xxx
8yyy*
NV Media card: Compare the data in the drive with file xxx
9555*
NV media card: Clear the warning suppression flag
9666*
NV media card: Set the warning suppression flag
9777*
NV media card: Clear the read-only flag
9888*
NV media card: Set the read-only flag
9999*
NV media card: Erase and format the NV media card
Transfer electronic nameplate motor object parameters from the drive to an encoder connected to the drive or an option
110S0
module.
Transfer electronic nameplate motor objects parameters from an encoder connected to the drive or option module to the
110S1
drive parameters.
110S2
As 110S0, but for performance object 1
110S3
As 110S1, but for performance object 1
110S4
As 110S0, but for performance object 2
110S5
As 110S1, but for performance object 2
Transfer electronic nameplate motor object parameters from the drive to an encoder connected to the drive or an option
110S6
module in the Unidrive SP format.
12000**
Only display parameters that are different from their default value. This action does not require a drive reset.
Only display parameters that are used to set-up destinations (i.e. DE format bit is 1). This action does not require a drive
12001**
reset.
15xxx*
Transfer the user program in an option module installed in slot 1 to a non-volatile media card file xxx
16xxx*
Transfer the user program in an option module installed in slot 2 to a non-volatile media card file xxx
17xxx*
Transfer the user program in an option module installed in slot 3 to a non-volatile media card file xxx
18xxx*
Transfer the user program from file xxx in a non-volatile media card to an option module installed in slot 1.
19xxx*
Transfer the user program from file xxx in a non-volatile media card to an option module installed in slot 2.
20xxx*
Transfer the user program from file xxx in a non-volatile media card to an option module installed in slot 3.
21xxx*
Transfer the user program in an option module installed in slot 4 to a non-volatile media card file xxx.
22xxx*
Transfer the user program from file xxx in a non-volatile media card to an option module installed in slot 4.
* See Chapter 9 NV Media Card Operation on page 130 for more information on these functions.
** These functions do not require a drive reset to become active. All other functions require a drive reset to initiate the function.
To allow easy access to some commonly used functions, refer to the table overleaf. Equivalent values and strings are also provided in the table
above.
Unidrive M702 User Guide
Issue Number: 3
Electrical
Getting
Basic
installation
started
parameters
the motor
Running
NV Media Card
Optimization
Operation
Action
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
UL listing
information
101

Hide quick links:

Table of Contents
loading

Table of Contents