Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
These operating instructions apply to devices with the following order numbers 6AV7260..Scope of the documentation The documentation for the IPC includes the following: ● SIMATIC IPC677D Quick Install Guide with product information about the device, for example important notes ● SIMATIC IPC677D operating instructions The documentation is supplied with the IPC in German and English in electronic form as a PDF file on the Documentation and Drivers CD/DVD.
Page 4
In these operating instructions, the term "device" is also used to refer to the "SIMATIC IPC677D". The SIMATIC IPC677D consists of an operator panel with touch screen and a SIMATIC IPC627D computer unit. In these operating instructions, you also find descriptions and illustrations of the SIMATIC IPC627D which apply to the SIMATIC IPC677D.
Connecting the PROFINET strain relief .................. 47 Commissioning the device ........................49 General information on commissioning .................. 49 Switching on the device ......................50 Windows Action Center......................51 Notes on different device configurations................. 51 SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 6
Integrating a new hard disk drive in the RAID system ............84 Service and spare parts ......................86 Cleaning the Device Front ..................... 88 Separating the control unit from the computer unit ..............89 Connecting the control unit with the computer unit ..............90 SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 7
Hardware descriptions ......................129 8.5.1 Motherboard .......................... 129 8.5.1.1 Structure and functions of the motherboard ................. 129 8.5.1.2 Position of the interfaces on the motherboard ..............130 8.5.1.3 Internal interfaces ......................... 131 8.5.1.4 Front ports ..........................132 SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 8
Windows Embedded Standard 7 Professional ..............170 Technical support..........................173 Service and support ......................173 Troubleshooting ........................174 Notes on the use of third-party modules ................176 List of abbreviations ..........................177 Glossary .............................. 183 Index ..............................191 SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Overview Product description Devices with capacitive multi-touch screen Devices with resistive single touch screen SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 10
The delivery note contains information on the precise scope of functions and product package for your device. The SIMATIC IPC677D is available in the following device variants, which differ in regard to the display size, operating method and optional expansions.
(requires up to 512 MB in main memory) DVI resolution of 640 × 480 pixels up to 1920 × 1200 pixels • Graphics memory is claimed in main memory (dynamic UMA) • Triple Head Mode • SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 12
Internal: 1 × USB 3.0 high current for internal USB stick/dongle • Serial V.24 port COM2/LPT optional Monitor 1 x DVI-I (VGA monitors can be connected with a DVI/VGA • adapter acquired separately) 1 x DisplayPort • SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 13
OPC for integrating in SIMATIC software • Client server architecture • Structure of log files • SIMATIC IPC Image & Partition Software tool for local data backup and hard disk Creator V3.3.2 or higher partitioning SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Note: The BIOS setup entry "After Power Failure" has been set to "Power On". This means the device is switched on with the on/off switch. You then do not need to press the on/off button. ⑪ 4 status LEDs Status display of the operating state SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 15
② ③ Devices with resistive single-touch screen Note If you open the sealed cover for the front USB port, the degree of protection IP65 for the front of the device is no longer guaranteed. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
"Buffer memory SRAM (optional) (Page 66)". Example programs for controlling the LEDs under Windows operating systems is available on the Internet at the following address: Technical Support (http://www.siemens.de/automation/csi_en_WW) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
SNMP. PROFINET Virtual LEDs CP is active STOP CP is in the stop state Flashes There are no "slow flashing" or "fast flashing" states. See also Industry Automation and Drive Technologies - Homepage (http://www.siemens.com/automation/service&support) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Overview 1.3 Accessories Accessories Accessories are available for your device. These are not included in the product package. You can find Information on available accessories on the Internet at: Industry Mall (https://mall.industry.siemens.com) Expansion components and accessories (http://www.automation.siemens.com/mcms/pc- based-automation/en/industrial-pc/expansion_components_accessories) Other accessories ●...
Note that the device is classified as "Open Type" for use in the area of Industrial Control Equipment (UL508). Installation of the device in an enclosure complying with UL508 for specific permitted mounting positions (see corresponding section) is a prerequisite for approval or operation in accordance with UL508. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 20
Avoid high-frequency radiation: • Remove radiation sources from the environment of the device. • Switch off radiating devices. • Reduce the radio output of radiating devices. • Observe the information on electromagnetic compatibility (Page 112). SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 21
ESD Guideline (Page 113). Industrial Security Siemens offers products and solutions with Industrial Security functions that support the safe operation of equipment, solutions, machines, devices and/or networks. They are important components in a comprehensive Industrial Security concept. As a result the products and solutions from Siemens are constantly evolving.
• Always use suitable cleaning agents. Read the information about Chemical resistance of the HMI devices and industrial PCs (http://support.automation.siemens.com/WW/view/en/39718396) on the Internet. Note Use in an industrial environment without additional protective measures...
Page 23
A small number of defective pixels in the display is therefore unavoidable. This does not present a functional problem as long as the defective pixels are not bunched in one location. Additional information is available in the section "General technical specifications (Page 121)". SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Death or serious injury could occur. Make sure that the damaged device is not inadvertently installed and put into operation. Label the damaged device and keep it locked away. Send off the device for immediate repair. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
COA label Ethernet address 1 BIOS setup, "Main" menu Ethernet address 2 CP 1616 onboard MAC Address Layer 2 (only for PROFINET devices) CP 1616 onboard MAC address PROFINET (only for PROFINET devices) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 27
The COA label is present only when Windows Embedded Standard 7 or Windows 7 is installed. ● COA label of a device with the Windows Embedded Standard 7 operating system ● COA label of a device with the Windows 7 operating system SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Mounting in horizontal format Note Mounting precautions • The total power for USB and PCI/PCIe expansions cannot exceed 30 W. • Operation of a DVD drive in the inclined position is not permitted. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
The force of the clamps or operation of the device may not lead to deformation of the material in order to achieve the degrees of protection described below. Note Read the information in the section "Installation guidelines (Page 31)". SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 30
Width and height must be interchanged for mounting in vertical format. Device with capacitive multi-touch screen Device with resistive single-touch screen Installation depth Information on the overall depth is available in the section "Dimension drawings (Page 115)". SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
● Equip the control cabinet with struts for stabilizing the mounting cut-out. Install struts where necessary. ● The device with AC power supply meets the requirements for fire protection enclosures according to EN 60950-1 and can therefore be installed without an additional fire protection covering. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 32
• Fixing with mounting brackets or mounting clips • Make sure that the size of the mounting cut-out is correct; see section Preparing the mounting cutout (Page 29). See also Technical specifications (Page 121) Dimension drawings (Page 115) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
● With 6 mounting brackets (available as accessories) Positions of the mounting clips or mounting brackets for IP65 To achieve the IP65 degree of protection for the device, the mounting clips or brackets must be affixed at the positions shown below. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Tighten the threaded pin to secure the mounting clip. The maximum torque when tightening the threaded pins of the mounting clips is 0.5 Nm. Repeat steps 2 and 3 for all mounting clips. Check the fit of the mounting seal. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
● All packaging components and protective films have been removed from the device. ● You have mounting brackets to hand ● 2.5 mm hexagonal spanner Procedure Note If the mounting seal is damaged or protrudes over the device, the degree of protection is not guaranteed. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 36
The maximum permissible torque is 0.5 Nm. Repeat steps 2 and 3 until all mounting brackets are attached. Check the fit of the mounting seal. See also Preparing the mounting cutout (Page 29) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
• Always pull out the power plug when you are not using the device or if the device is defective. The power plug must be freely accessible. • Properly connect the device to a protective conductor. • Use a central isolating switch in the case of cabinet installation. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
I/O modules are safely discharged to ground. The equipotential bonding connection of the device is located underneath the device and is identified by the following symbol: SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
VDE 0100 Part 100, or IEC 60364-1). Operation on ungrounded or impedance-grounded power networks (IT networks) is prohibited. WARNING Rated voltage The permitted nominal voltage of the device must conform with local mains voltage. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 40
A flexible cable with UL approval and with CSA label which has the following features is to be used: Type SJT with three conductors, min. 18 AWG conductor cross-section, max. length 4.5 m, and tandem grounded connector 15 A, min. 250 V. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
1.3 mm (AWG16) and a maximum cross- section of 3.3 mm (AWG12). Note The 24 V DC power source must be adapted to the input data of the device (see specifications). SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 42
The device will simply fail to turn on. After the power supply has been connected correctly, the device will again be ready to operate. See also General technical specifications (Page 121) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
The connected or built-in I/Os, such as USB drives, should not introduce a reverse voltage into the device. Reverse voltages exceeding 0.5 V to ground that are generated by connected or installed components can prevent proper operation of the device or lead to its destruction. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
SIMATIC NET DVD. This software package and the documentation are not part of the product package. Additional information Additional information is available in the catalog and the online ordering system Industry Mall (https://mall.industry.siemens.com). SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
SIMATIC NET products CP 1616/CP 1604, CP 1616 onboard, the developer kit. Configuration Manual This provides you will all the information necessary for Commissioning PC Stations commissioning and configuring a PC as a PROFINET IO controller or IO device. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
CP16xx.sys. Further information You can find the information on specific products in the Internet at the address: Product- related Information SIMATIC NET (http://www.siemens.com/simatic-net) 3.3.8 Connecting Ethernet/USB strain relief The Ethernet/USB strain relief supplied in the product package is used to prevent accidental removal of the Ethernet cable and Industrial Ethernet FastConnect connector from the device.
M3 to the de- vice housing. 2. Connect the PROFINET cables with the device and secure the PROFINET con- nector with straight cable outlet to the ② strain relief with cable ties SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 48
Mounting and connecting the device 3.3 Connecting the device SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
● The device is connected to the power supply. ● The protective conductor is connected. ● The connection cables are plugged in correctly. ● The following hardware is available for initial commissioning: – One USB keyboard – One USB mouse SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
6. If the device is delivered with pre-installed software, the setup of the SIMATIC IPC Wizard is started automatically after operating system installation (see the following section). The installation of the operating system is complete. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Partition C: System, NTFS, 50 GB Partition D: Data, NTFS, remaining capacity Note You can find information regarding Intel RAID controllers in the RAID documentation on the included "Documentation and Drivers" DVD in the Drivers\RAID\Intel directory. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 52
In extreme cases, input from the keyboard and touch screen may be delayed for a brief period. Before you replace the defective hard disk, create a backup copy of the system. See also Managing RAID systems (Page 81) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
• Protect the device and plant with a suitable uninterruptible power supply (UPS). 1. Open the function "Start > Shut down" in the Start menu. The green LED "PC ON/WD" changes to yellow. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 54
Commissioning the device 4.5 Switching off the device SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Only touch the touch screen with your fingers or a suitable touch stylus. ● On-screen keyboard with touch device (see section "Using the on-screen keyboard") ● External keyboard, connected via USB ● External mouse, connected via USB SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Appearance of blisters under extreme ambient conditions Under extreme environmental conditions such as high atmospheric humidity and temperature, bubbles can form on the touch surface in rare cases. This only affects the appearance and does not represent any functional restriction. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Windows operating system, as well as with the application to be used and its functions. Ensure that the gestures which the user executes on the multi-touch display are recognized by the application. It is possible that certain gestures need to be trained beforehand. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 58
● Electromagnetic interference is present that exceeds the specification according to EN 61000-4-2. Once the interference is over, the touch screen is no longer locked. See also Chemical resistance of the HMI devices and industrial PCs (http://support.automation.siemens.com/WW/view/en/39718396) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
● Monitoring of hard disks, memory cards and SSD drives with S.M.A.R.T. functionality ● Watchdog (hardware or software reset of the computer) ● Operating hours meter (information on the cumulative run time) ● Hard disk status and status of the RAID system SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
The temperature error is retained in memory until temperatures have fallen below the thresholds and it is reset by one of the following measures: ● Acknowledgment of the error message by the monitoring software ● Restart of the device SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Windows and damage to the installation. Watchdog monitoring times The monitoring time can be configured with the DiagBase or DiagMonitor software. Note When you change the monitoring time, the change becomes effective immediately. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Note Windows Embedded Standard The Enhanced Write Filter is deactivated in the Windows Embedded Standard default state. • Back up your data after installation of the operating system and programs. • Activate the EWF. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 63
● "Start > All Programs >Siemens Automation > SIMATIC > EWF Manager > EWF Manager" Configure the SIMATIC IPC EWF Manager as follows: ● "Start > All Programs > Siemens Automation > SIMATIC > EWF Manager > EWF Settings" ● Click the "SIMATIC IPC EWF Manager" icon in the system tray.
FBWF is disabled by factory default in the operating system images for SIMATIC IPC and must be enabled and configured by the user. When you enable FBWF, the folders C:\FBWF and D:\FBWF are authorized for writing by default. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 65
• fbwfmgr /removeexclusion C: \Test.txt Remove file • fbwfmgr /removeexclusion C: \Test folder Remove folder • fbwfmgr /? Call up the help function Detailed instructions on FBWF are available on the Internet (http://msdn.microsoft.com/en- us/library/aa940926(WinEmbedded.5).aspx). SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
An ISO file contains a memory image of the content of a CD or DVD structured in the ISO 9660 format. ● Remote reboot: An AMT PC can be booted from a bootable ISO file made available by another PC. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
SIMATIC IPC Remote Manager The "SIMATIC IPC Remote Manager" software is available for utilization of the AMT functions with SIMATIC IPCs. The software can be ordered from the Siemens online ordering system. For detailed information about "SIMATIC IPC Remote Manager", refer to the corresponding product documentation: SIMATIC IPC Remote Manager (http://support.automation.siemens.com/WW/view/en/48707158)
Page 68
The warranty does not cover a reset of the hardware in the event of a loss of a password. Please store the password carefully and make sure it is protected against unauthorized access. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
All technical data and approvals apply only to expansion units which are released by SIEMENS. Siemens disclaims any liability for impairment of functions caused by the use of third-party devices or components. Observe the installation instructions for the components. UL approval of the device only applies when the UL-approved components are used according to their "Conditions of...
Always take appropriate precautionary measures when handling these components. Refer to the ESD directives on handling electrostatic sensitive components. Note We strongly recommend using only memory modules approved by Siemens. Siemens disclaims any liability for impairment of functions caused by the use of third-party memory modules.
Page 71
Display of the current memory configuration A new memory module is automatically detected. When switching on the device and starting the BIOS Setup using , the current memory size is displayed under "Total Memory". SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
3. Insert the expansion card into the intended slot. 4. Mount the card bracket and insert ③ the slider ① 5. Screw in the slot cover of the expansion card. 6. Insert the slider. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 73
Notes on the allocation of resources The slots for the expansion cards come with exclusive interrupts. The assignment of the PCI IRQ line to the PCI slot is explained in the chapter "Bus board (Page 133)". SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
2.5" hard disk: Two slots for 2.5" hard disks ② Drive bay for 2.5" hard disks One SSD drive Item Description ① SSD drive: Two slots for SSD drives ② Drive bay for SSD drive SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Loosen the 4 screws on the holding plates. Do not remove the screws. Remove the hard disk drive including the mounting plate from the bay. Disconnect the power supply and the data cable from the drive. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 76
Removing hard disk in removable drive bay See chapter "Maintaining and repairing the device", "Removing and installing hardware", section "Removing and installing the hard disk in the removable drive bay (Page 92)". Installation Proceed in reverse order in each case. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
1. Remove the drive bay module. 2. Disconnect the power supply and the data cable from the drive. ① 3. Loosen the screws of the drive. 4. Remove the drive from the bay. Installation Proceed in reverse order. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
DVD drive. A DVD drive The figure shows a mounted DVD drive. Two 2.5" hard disks in removable drive bay Item Description ① 2.5" hard disk ② Tray for one 2.5" hard disk SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
• Power supply connector ② • SATA connector 3. Loosen the designated rivets on the left and right on the cover with a screwdriver and put the cover down with the optical drive facing down- wards. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 80
7. Loosen the four screws that con- nect the optical drive with the drive bay and pull out the optical drive to the front from the drive bay. Installing external drive Proceed in reverse order. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Example for a RAID1 system during the boot phase of the system You can configure RAID hardware with in the boot phase. The associated description is available on the "Documentation and Drivers" DVD. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Execution of keyboard, mouse or touch screen commands may be briefly delayed in extreme situations. This could result in operator errors on the machine or plant. Do not operate safety-critical functions when a hard disk has failed. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
BIOS setup menu "Boot". Otherwise, the system will boot from the hard disk you have just installed and the message "Operating system not found" will be displayed. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Sequence The following figure is an example for the automatic rebuilding process. A defective hard disk is still displayed during the rebuilding process. This display disappears when the rebuilding process is completed. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 85
The new hard disk is then assigned to a SATA port and is integrated into the RAID system. A defective hard disk is still displayed during the rebuilding process. This display disappears when the rebuilding process is completed. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Make sure you take precautionary measures even when you open the device, for example, when opening device doors, device covers or the housing cover. For more information, refer to the chapter "ESD Guideline (Page 113)" SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 87
UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". We are not liable for functional limitations caused by the use of third-party devices or components. See also Spare parts and repairs (http://support.automation.siemens.com/WW/view/en/16611927) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Cleaning the Device Front 1. Switch off the device. 2. Dampen the cleaning cloth. 3. Spray the cleaning agent on the cloth and not directly on the device. 4. Clean the device with the cleaning cloth. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Push the computer unit back ⑤ slightly until the screw lies exactly in its recess. ④ Pull the connector fully out. Lift up the computer unit and gently place it on a soft surface. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Insert the metal door in the riv- ⑥ and close the metal door ⑦ with the knurled screw Slide the computer unit all the way forward to the stop screw ⑧ and screw in the 4 screws. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Internal hard disk or hard disk in removable drive bay Status display RAID BIOS RAID software SATA connection of Drive the motherboard HDD0 alarm Port 0 Device port 0 SATA 0 HDD1 alarm Port 1 Device port 1 SATA 1 SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
3. Place the hard disk bay top down on a soft surface. ② 4. Loosen the screws of the drive. 5. Remove the drive from the removable drive bay. Installation Proceed in reverse order. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
● The device is disconnected from the mains and all connecting cables have been removed. Note You can also replace the battery while the device is running; do not touch anything with the device in this case. We recommend switching off the device beforehand. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 94
2. Remove the battery holder. 3. Detach the cable. 4. Remove the old battery. 5. Fasten the new battery and reinsert the battery holder. 6. Close the battery compartment. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
(Torx T10) on the side. 3. Lift up the power supply slightly and remove the identified power supply connector from the power supply unit. 4. Lift out the power supply unit completely. Installation Proceed in reverse order. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
2. Remove the drive bay module for hard disks. 3. Remove the power supply. ① 4. Remove the screws on the bus board. 5. Pull the bus board from the motherboard. Installation Proceed in reverse order. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
2. Loosen the four screws on the enclosure. 3. Take the power supply fan out of the enclosure. Installation Note Install only a fan of the same type. Note the correct mounting position of the fan. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 98
② ● Run the power supply cable along the housing edge and fasten any excess cable as loop as shown in the illustration. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Note Install only a fan of the same type. Note the correct fan mounting position: Make sure that the blades of the fan are on the outside of the housing. Proceed in reverse order. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
If the processor type is changed, the BIOS must be updated so that the suitable microcode is loaded. Information about original spare parts for SIMATIC IPCs is available on the Internet at: – Contacts (http://www.siemens.com/automation/partner) – SIMATIC IPC after-sales information system (http://www.siemens.com/asis) Procedure ① 1. Loosen the screws The fourth screw is hidden by the air guide in the figure.
Page 101
If the installed processor is operated with a higher clock frequency than permitted, it can be destroyed or cause loss of data. Operate the processor only at a clock frequency that is equal to or less than the permitted clock frequency. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Note Before you install new drivers or operating system updates for Windows MUI versions, configure the regional menu and dialog settings and the default English (US) language. other operating systems Contact the corresponding manufacturer. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
If you use storage controllers that are unknown to the operating system, for example a RAID controller or AHCI controller, copy the respective controller driver to a USB stick and keep this USB stick to hand. The controller driver is required during installation. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 104
You can set up partitions during the installation process and integrate storage controllers that are unknown to the operating system. To do so, select "Custom (advanced)" when prompted for the installation type in the "Install Windows" installation program. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 105
Please read the information in the section "Information for systems with RAID controller or AHCI controller". Drive options For display of additional functions that you can use to set up the data medium, (advanced) see figure "Windows installation window "Drive options (advanced)"". SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 106
Integrate this driver before you partition the data medium and before you install the operating system. For more information on integrating the storage controllers, refer to the section "Information for systems with RAID controller or AHCI controller". SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 107
1. Connect the USB stick with the controller driver to the device. 2. Start the "Install Windows" installation program as described above. 3. Select "Load Drivers" in the Windows installation window. 4. Select the respective driver on the USB stick. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
1. Choose: "Start > Control Panel > Clock, Language, and Region > Regional and Language Options" 2. Select the "Keyboards and Languages" tab. 3. Click the "Install/uninstall languages" button and make the required changes. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Note Before you install new drivers or operating system updates for Windows MUI versions, configure the regional menu and dialog settings and the default English (US) language. other operating systems Contact the corresponding provider. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
(images). SIMATIC IPC Image & Partition Creator supports the burning of DVD media only. You can order the tool using the Siemens online ordering system (http://www.siemens.com/automation/mall). For more information about SIMATIC IPC Image & Partition Creator, refer to its product documentation.
Certificates and approvals ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001:2008. This has been certified by DQS (the German society for the certification of quality management systems).
Low-voltage directive The device with AC power supply complies with the requirements of the EC Directive 2006/95/EC "Low Voltage Directive". Compliance with this standard has been verified according to EN 60950-1:2006 + A11:2009 +A1:2010 +A12:2011. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
The material with which this person comes into contact is of particular significance. The figure shows the maximum electrostatic voltages with which a person is charged, depending on humidity and material. These values conform to the specifications of IEC 61000-4-2. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 114
This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
The device should only be connected to a 24 V DC power supply which meets the re- quirements of safe extra low voltage (SELV) according to IEC/EN/DIN EN 60950-1. A protective conductor must also be used (see section "Connecting the 24 VDC power sup- ply (Page 41)"). SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Serial ATA, See order documentation for features ∗2 Restriction for DVD burner drives: 10 to 58 Hz: 0.019 mm / 58 to 500 Hz: 2.5 m/s Burner can only be operated in an interference-free environment SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 124
For unique labeling, the Ethernet ports are numbered on the enclosure. The numbering by the operating system can differ. No teaming with AMT. When using AMT, the interface x1 p1 must be used for connection to remote maintenance. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Shock resistance, tested in accordance with IEC 60068-2-27, IEC 60068-2-29 During operation 50 m/s , 30 ms Storage/transport 250 m/s , 6 ms Restriction for DVD burners: Read, write and burner operation only permitted in an interference- free environment SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
0.17 A USB ports max. 0.06 A max. 0.54 A max. 13 W PCI/PCIe slots 0.16 A max. 1.54 A max. Max. 37 W Operator panel max 0.14 A max. 1,33 A max. 32 W SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
50 A for 1 ms Active power 176 W Apparent power 190 VA Output data Voltages +12 V / 12.5 A Secondary power output Max. 150 W Power Good signal of the AC power supply SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
13 A for 50 ms independent) Active power 176 W Output data Voltages +12 V / 12.5 A Secondary power output Max. 150 W Power Good signal of the DC power supply SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
The essential components of the motherboard are the processor and the chip set, two slots for memory modules, internal and external interfaces and the Flash BIOS. ① Processor heat sink ② Slot for the bus board ③ Two memory module slots SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Position of the interfaces on the motherboard Interfaces The motherboard of the device features the following interfaces: ● Interfaces for the connection of external devices ● Interfaces for internal components (drives, bus boards etc.) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Spare HDD Internal X803 LED display Pin assignment of the device fan supply, X512 Pin no. Short description Meaning Input/Output Ground +12 V Switched voltage supply Output CPU FAN_CLK Clock signal Input PWM signal Output SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Interface for I/O front USB 2.0 Internal X561 Internal USB 2.0 interface (USB channel 6) USB 3.0 Internal X560 Internal USB 3.0 interface (USB channel 3) See also Industry Automation and Drive Technologies - Homepage (http://www.siemens.com/automation/service&support) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Slot 2 PCI ③ 12 V power supply connection Variant 2 has one PCI and one PCIe slot. ① Slot 1 PCI ② Slot 2 PCI Express x16 ③ 12 V power supply connection SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Meaning Input / output Data carrier detect Input Received data Input Transmit data Output Data terminal ready Output Ground Ready for operation Input Request to send Output Clear to send Input Incoming call Input SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Output Analog green (G) Analog Green Signal Output Analog blue (B) Analog Blue Signal Output Analog horizontal sync Analog Horizontal Sync Signal Output (HSYNC) Analog ground Analog ground (analog R, G, & return) (GND) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Input / output VBUS + 5 V (fused) Output Data line Input / output Data line Input / output Ground – Data line Input Data line Input Ground – Data line Output Data line Output SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Receive data Output 7, 8 SYMT- Internal 75 Ohm terminating resistor Shield LED 1 Lights up green: link LED 2 Lights up yellow: Activity Optional product variant Auto Negotiation and auto crossover are supported SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 145
Motherboard resources Cascaded 2004 2007 Motherboard resources FFFF FFFF Motherboard resources Interrupt Assignments The functions are assigned different interrupts, depending on the operating system. A distinction is made between the PIC and APIC modes. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 146
Host PCI-IRQ A to H is assigned to IRQ 16 to 23 permanently in APIC mode. Host PCI-IRQ A to H will be automatically assigned IRQ 0 to 15 by BIOS in PIC mode. A specific assignment can not be enforced. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 147
1, 3 Requirement: The modules in the PCI slots each require only one interrupt Requirement: VGA and PCIexpress do not require an interrupt Requirement: VGA does not require an interrupt and Ethernet1 is disabled SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
The IO base controller user program runs on the PC. This program accesses the functions of the IO base user program interface. Data traffic is routed via the communication processor to several SIMATIC S7 PROFINET IO devices, ET 200S over Industrial Ethernet. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 150
IO base user program interface. Data traffic is routed via the CP 1616 onboard communication processor to a PC as PROFINET IO controller, or to an S7-400 automation system with CP 443-1 over Industrial Ethernet. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
The firmware loader can use this information to check if the firmware is compatible to the device. Read the information provided along with the loader file, for example, in the readme file. This information is also displayed in the firmware loader when the FWL file is loaded. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 152
Note Ensure that the loader file you are using for the update is suitable for the version of firmware on your module. If you have any doubts, contact your local Siemens consultant. Note Be aware that aborting the loading process may result in an inconsistent state in your module.
Setup parameters may not be included, depending on your order. The interface of your BIOS Setup can deviate from the figures in this document. You can find a detailed description of the BIOS on the Support website under Entry ID 92189185 (http://support.automation.siemens.com/WW/view/en/92189185). SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
• Secure Boot Option Configuration settings to start the device in Secure Boot mode. The only software modules loaded are those that are known to be safe for the BIOS or the operating system. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Menu layout The following figure is an example for the main menu. Device-specific information is shown as blurred. ① ④ Header Help area ② ⑤ Menu bar Key assignment ③ Settings, submenus and device-specific information SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 156
Advanced Configure hardware using different submenus Security Security functions, e.g., setting a password Power Specify CPU settings and switch-on functions. Boot Determine boot options, e.g., boot order Exit Save and exit (see Exit menu) SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
You can then refer to these entries for any future hardware modifications. Note Print out the table below and keep the pages in a safe place once you made your entries. The default setup settings vary depending on the ordered device configuration. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 158
Visible depending on the ordered device configuration Only visible if the corresponding parameter "Internal COM #" is enabled. Only visible if "Internal LPT" is enabled. Only available if an Azalia HD audio controller is installed. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 159
USB Port 8 (USB2 P8, internal) Enabled USB Port 9 (USB2 P9, internal) Enabled USB Port 10 (USB2 P10, internal) Enabled USB Port 11 (USB2 P11, internal) Enabled Only with rack devices Only with box devices SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 160
TPM Status Depending on configura- tion TPM Operation No Operation TPM Force Clear Disabled Set Supervisor Password Set User Password Power-on Password Disabled User Access Level Full Visible depending on the ordered device configuration SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 161
Local settings Boot Type Dual Boot Type Quick Boot Enabled Quiet Boot Enabled Network Stack Disabled PXE Boot capability Disabled Add Boot Options Auto USB Boot Enabled EFI Device First Enabled Boot Delay Time SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
BIOS update Check regularly if updates are available for download to your device. Additional information can be found on the Internet at the following address:After Sales Information system (http://www.siemens.com/asis). Noting down and restoring BIOS Setup settings NOTICE Irretrievable loss of data All BIOS Setup settings are deleted after the BIOS update.
The error messages output by system BIOS are listed below. For information on error messages output by the operating system or application programs, refer to the corresponding manuals. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
SIMATIC IPC with Intel® AMT from it. The following figure shows remote maintenance of SIMATIC IPCs with Intel® AMT, e.g. for troubleshooting a corrupt operating system or incorrect BIOS settings: SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
The local IPC is known below as the "AMT PC". The sections contain the following information: ● AMT settings in the MEBx and in the BIOS setup ● Basic configuration of AMT ● Further useful notes SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
3. Select the "Active Management Technology Support" command in the Advanced menu. 4. Activate the option "Intel AMT Support". 5. Activate the option "Intel AMT Setup Prompt". 6. Exit the BIOS Setup with key (Save and Exit). SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 167
5. Switch to the "Intel(R) ME General Settings" submenu and enable access via the network with "Activate Network Access". 6. Confirm the dialogs that appear with "Y". Drivers are automatically installed once as required in the subsequent restart. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
5. Confirm this prompt with "Y" to discard all settings in the Management Engine (ME). 6. For IPC627C/827C/677C/647C/847C/427D/477D/Field PG M4, you now need to set the "Un-Configure ME" menu command in the BIOS back to Disabled. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
2. Select the value "KVM" for "User Consent". To allow a user with administrator privileges to avoid this code query, follow these steps: 1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx. 2. Enable "Opt-in configurable from remote IT". SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Network Diagnostics Available Pagefile Available Printing Utilities and Management Available Registry Filter Available Remote Assistance Available Remote Client Available Remote Desktop Available SIMATIC IPC DiagBase Available, V1.4 Speech Not available System Management Administrative Tools Available SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 171
Wireless Networking Available Note the licensing agreements for Windows Embedded Standard 7 Professional. Additional information on language selection is available in section "Setting up the language selection by means of the Multilanguage User Interface (MUI)". SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 172
Technical information 8.8 Functional scope in Windows SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (http://www.siemens.de/automation/csi_en_WW) ● Support request form (http://www.siemens.com/automation/support-request) ● After-sales information system for SIMATIC PC / PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa- db/en/Pages/default.aspx)
2. Select BIOS setup, "Main" menu. 3. Set the time and date. Although the BIOS setting is The backup battery is dead. Replace the backup battery. OK, the time and data are still wrong. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 175
Change the boot priority of the boot device in the "Boot device not found" is boot priority in the BIOS setup or is Boot menu of the BIOS setup or permit boot device displayed excluded as a boot device in the boot priority SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
PC. If the error no longer occurs, the Signal frequencies or signal • third-party module was the cause of the fault. Replace this levels are not adhered to module with a Siemens module or contact the module Different connector pin • supplier. assignments If the PC still crashes, contact your technical support team.
Complementary Metal Oxide Semiconductors Complementary metal oxide semiconductors Certificate of authentication Microsoft Windows Product Key Certificate of License License authorization Communications Port Term for the serial interface Communication Processor Communication computer Central Processing Unit Cathode Ray Tube SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 178
FAQs FAT 32 File Allocation Table 32-bit 32-bit file allocation table FBWF File Based Write Filter Floppy disk Disk drive, 3.5" Front Side Bus Ground Chassis ground Hard disk Hard disk High Definition Audio SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 179
MS-DOS Microsoft Disc Operating System MTBF Mean Time Between Failures Multilanguage User Interface Multilanguage operating system with Windows with language toggling; 5 languages: German, English, French, Spanish and Italian Not Applicable SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 180
Bi-directional bus system designed for up to 32 nodes Real Time Clock Real-time clock Reliable Transfer Service Request to send Receive Data Data transfer signal SATA Serial Advanced Technology Attachment SCSI Small Computer System Interface SDRAM Synchronous DRAM SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 181
VT-D Virtualization Technology for Directed I/O Enables the direct assignment of a device (e.g. network adapter) to a virtual device. Windows 2000 Wide Area Network Wave Length Encoding Loss-free file format for audio data SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 182
Program monitoring with error detection and alarming. WLAN Wireless LAN LWireless local area network Wake on Local Area Network World Wide Web Execute Disable Capability Hardware implementation Extended Graphics Array Graphic standard, maximum resolution 1.024 x 768 pixels. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Cache High-speed access buffer for interim storage (buffering) of requested data. CE marking Communauté Européene The CE mark confirms compliance of the product with corresponding EC Directives, for example, with the EMC Directive. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 184
The data are stored in a configuration file and enable the operating system to load the correct device drivers and configure the correct device parameters. . If changes are made to the hardware configuration, the user can change entries in the configuration file using the SETUP program. . SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 185
10/100/1000 Mbps. Execute Disable Capability Hardware implementation that prevents mutual memory accesses by programs and applications. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 186
Intel Active Management Technology This technology permits the diagnostics, management and remote control of PCs. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 187
Legacy Boot Device Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. License key disk The license key disk contains the authorizations or license keys required to enable protected SIMATIC software.
Page 188
Restricted Access Location: Installation of the device in a production facility with restricted access, for example, a locked control cabinet. Recovery CD Contains the tools for configuring hard disks and the Windows operating system. Reset Hardware reset: Reset/restart of the PC using a button/switch. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 189
This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. STEP 7 Programming software for the creation of user programs for SIMATIC S7 controllers. Troubleshooting Error cause, cause analysis, remedy SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 190
Wake on Local area network. This function allows the PC to be started via the LAN interface. Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 195
Index WinAC module Power supply connection, 136 Windows 7 Installation, 103 Windows 7 Ultimate Data backup, 110 Windows Embedded Standard Data backup, 110 Windows Security Center, 51 Windows XP Professional Data backup, 110 SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...
Page 196
Index SIMATIC IPC677D Operating Instructions, 09/2014, A5E32995420-AC...