Scheduled + Reheat Mode; Using The Dhw Tank Temperature Home Page; Using The Dhw Tank Booster Mode; Schedules: Example - Daikin EGSQH10S18AA9W Operation Manual

Ground source heat pump
Hide thumbs Also See for EGSQH10S18AA9W:
Table of Contents
3.4.3
Scheduled + reheat mode
In scheduled + reheat mode (   ), the domestic hot water control is
the  same  as  in  scheduled  mode.  However,  when  the  DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis  value  =  [6­0C]–[6­08];  example:  35°C),  the  DHW  tank
heats up until it reaches the reheat set point ([6­0C]; example: 45°C).
This ensures that a minimum amount of hot water is available at all
times.
Example: 
T t
[6-0A]=
60°C
[6-0B]=
50°C
[6-0C]=
45°C
[6-08]
[6-0C]–[6-08]=
35°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
[6­0A]
Storage comfort
[6­0B]
Storage eco
[6­0C]
Reheat
[6­08]
Reheat hysteresis
3.4.4
Using the DHW tank temperature home
page
Typical DHW tank temperature home pages
Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  Depending  on  an  installer  setting,
either  an  actual  temperature  or  a  number  of  people  is  displayed  to
indicate  the  domestic  hot  water  tank  temperature.  The  examples  in
the illustrations below are in DHW tank mode = Scheduled.
User profile = Basic
Mon
15:20
Tank
60°C
Desired temperature
Mon
15:20
Tank
4
Desired temperature
To read out and adjust the desired reheat temperature (in
scheduled and reheat mode)
1 Go  to  [7.4.3.3]: 
  >  User  settings  >  Preset  values  >  Tank
temperature > Reheat.
Result: You can read out the desired reheat temperature. 
2 Press 
 or 
 to adjust.
To read out and overrule the active or next scheduled desired
temperature (in scheduled mode or scheduled + reheat mode)
1 Go to the DHW tank temperature home page (Tank).
60°C
4
Result: 
 or 
2 Press 
 or 
 to overrule. Note: If the desired temperature is
weather dependent, you cannot change it on the home page.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351750­1C – 2014.03
1
2
3
4
5
t
14:00
21:00
User profile = Detailed
Mon
15:20
60°C
Tank
Storage comfort
Tue
00:00
Mon
15:20
4
Tank
Storage comfort
Tue
00:00
 is displayed.
3.4.5
Using the DHW tank booster mode
To activate the DHW tank booster mode (method 1)
1 Go to the DHW tank temperature home page (Tank).
2 Press 
 for more than 5 seconds.
To activate the DHW tank booster mode (method 2)
Prerequisite: User profile = Detailed
1 Go to the DHW tank temperature home page (Tank).
2 Press 
 to select  .
3.5
Schedules: Example
INFORMATION
The procedures to program other controls are similar.
In this example:
▪ Room temperature schedule in heating mode
▪ Monday = Tuesday = Wednesday = Thursday = Friday
▪ Saturday = Sunday
To program the schedule
1 Go  to  [7.3.1.1]: 
  >  User  settings  >  Set  schedules  >  Room
temp. > Set heating schedule.
2 Select Empty and press 
3 Program the schedule for Monday. See below for more details.
4 Copy  from  Monday  to  Tuesday,  Wednesday,  Thursday  and
Friday. See below for more details.
5 Program the schedule for Saturday.
6 Copy from Saturday to Sunday.
7 Save  the  schedule  and  give  it  a  name.  See  below  for  more
details.
To program the schedule for Monday
1 Use 
 and 
 to select Monday.
2 Press 
 to enter the schedule for Monday.
3 Program the schedule for Monday:
▪ Use 
 and 
 to select an entry.
▪ Use 
 and 
 to change the value of an entry.
To copy from one day to another
1 Select  the  day  from  which  you  want  to  copy  and  press 
Example: Monday.
2 Select Copy day and press 
3 Set the days you want to copy to Yes and press 
Tuesday = Yes, Wednesday = Yes, Thursday = Yes and Friday
= Yes.
To save the schedule
1 Press 
, select Save schedule and press 
2 Select  User  defined  1,  User  defined  2  or  User  defined  3  and
press 
.
3 Change  the  name  and  press 
temperature schedules). Example: MyWeekSchedule
To select which schedule you currently want to use
1 Go to [5]: 
 > Select schedules.
2 Select for which control you want to use a schedule. Example:
[5.1] Room temperature.
3 Select  for  which  operation  mode  you  want  to  use  a  schedule.
Example: [5.1.1] Heating.
4 Select a predefined or user­defined schedule and press 
3 Operation
.
.
. Example:
.
.  (Only  applicable  for  room
.
Operation manual
.
5
Table of Contents
loading

Table of Contents