Outdoor Unit - Panasonic WH-SDC09C3E8 Service Manual

Air-to-water
Hide thumbs Also See for WH-SDC09C3E8:
Table of Contents
11.4

Outdoor Unit

11.4.1 Install the Outdoor Unit
After selecting the best location, start installation
according to Indoor/Outdoor Unit Installation
Diagram.
1
Fix the unit on concrete or rigid frame firmly and
horizontally by bolt nut (ø10 mm).
2
When installing at roof, please consider strong
wind and earthquake. Please fasten the
installation stand firmly with bolt or nails.
(Unit in mm)
11.4.2 Connecting the Piping
SDC09C3E8/UD09CE8, SDC12C9E8/UD12CE8,
SDC14C9E8/UD14CE8,SDC16C9E8/UD16CE8
Connecting the Piping to Outdoor Unit
Decide piping length and then cut by using pipe cutter. Remove burrs from cut edge. Make flare after inserting the
flare nut (locate at valve) onto the copper pipe.
Align center of piping to valves and then tighten with torque wrench to the specified torque as stated in the table.
Local pipes can project in any of four directions.
Make holes in the pipe panels for the pipes to pass
through.
Be sure to install the pipe panels to prevent rain from
getting inside the outdoor unit.
[Removing the service panel].
(1) Remove the three mounting screws.
(2) Slide the service panel downward to release the pawls.
After this, pull the service panel toward you to remove it.
Model
CAUTION
Do not over tighten, over tightening cause gas leakage.
Gas
ø15.88mm (5/8") [65 N•m]
42
Piping size (Torque)
Liquid
ø9.52mm (3/8") [42 N•m]
Table of Contents
loading

Table of Contents