Page 1
HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide April 2003 (Second Edition) Part Number 293164-002 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM...
Page 2
“as is” without warranty of any kind and is subject to change without notice. The warranties for HP products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.
User Interface Board ..........................2-21 PCI Riser Board Assembly........................2-22 Expansion Board..........................2-23 PCI Card Guide..........................2-24 Center Wall.............................. 2-25 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM...
Page 4
Ultra3 SCSI Hard Drives........................5-9 ATA Hard Drives ..........................5-10 Integrated NC7760 Gigabit Server Auto-Switching Network Interface Controller (NIC) ......5-11 Index HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM...
Improper repairs can create conditions that are hazardous. Audience Assumptions This guide is for service technicians. HP assumes you are qualified in the servicing of computer equipment, trained in recognizing hazards in products with hazardous energy levels, and familiar with weight and stability precautions for rack installations.
Page 6
AC power cord into a properly grounded AC outlet only. NOTE: Any indications of component replacement or printed wiring board modifications may void any warranty. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM...
In the United States and Canada, call 1-800-652-6672. • Outside the United States and Canada, refer to www.hp.com HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM...
Illustrated Parts Catalog This chapter provides the illustrated parts breakdown and spare parts list for the HP ProLiant DL320 Generation 2 server. The table in this chapter provides names and ordering numbers for all referenced spare parts. Mechanical Parts Exploded View...
Illustrated Parts Catalog System Components Exploded View Figure 1-2: System components exploded view HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:34 AM...
DVD-ROM/diskette drive assembly* 269046-001 c) ATA hard drive, 80 GB 287685-001 * Not shown continued HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:34 AM...
Page 11
Sliding rails and cable management system kit* 177852-001 Telco rack-mounting kit* 177853-001 Third-party cabinet rack-mounting kit* 177854-001 * Not shown HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:34 AM...
Removal and Replacement Procedures This chapter provides subassembly and module-level removal and replacement procedures for HP ProLiant DL320 Generation 2 servers. After completing all necessary removal and replacement procedures, run the diagnostics program to verify that all components operate properly.
WARNING: When installing the server in a telco rack, make certain that the rack frame is adequately secured to the building structure at the top and bottom. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
— SCSI hard drives • Single Channel Wide Ultra3 SCSI controller module • Integrated ATA RAID controller module HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 15
— Optical device/diskette drive assembly cable • Power supply • Battery • Memory modules • Processor • System board HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
For information on this system utility, refer to the NTREADME.HLP file on Diskette 1 of the NT Software Support Diskettes. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
CAUTION: Electrostatic discharge can damage electronic components. Ensure proper grounding before beginning any installation procedure. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 18
Figure 2-1: Removing the access panel To replace the access panel, reverse steps 1 through 3. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Figure 2-2: Removing the shipping/ejector key Reverse steps 1 through 3 to replace the shipping/ejector key. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
To replace the bezel blank, slide the blank into the empty bay until it locks into place. Store the shipping/ejector key in the chassis or other safe location for future use. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
To replace the assembly, slide the assembly into the bay until it is fully seated. 2-10 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Figure 2-5. Otherwise, store the shipping/ejector key inside the chassis for future use. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-11 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
4. Remove the four screws that secure the bezel to each side of the chassis. Figure 2-6: Removing the bezel screws 2-12 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 24
To install the bezel, reverse steps 1 through 7, omitting step 5. When the bottom of the bezel is hooked securely in place, the bezel top snaps into the chassis tabs. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-13 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
ATA hard drives to Cable-Select mode, if they are not already set in Cable-Select mode. 2-14 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
IMPORTANT: Always populate hard drive bays starting with the lowest ATA device number or recommended SCSI ID number. Figure 2-8: ATA device numbers or recommended SCSI ID numbers HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-15 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Description ATA secondary controller connector Secondary drive cable ATA primary controller connector Primary drive cable 2-16 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 28
Slide the tray toward the rear of the server and lift the tray out of the chassis (2). Figure 2-11: Removing the hard drive tray from the chassis HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-17 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 29
Reverse steps 1 through 7 to replace the hard drive. 2-18 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
To replace the SCSI module, reverse steps 1 through 4, ensuring that the SCSI module seats securely on the support posts. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-19 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
(center wall removed for clarity) Reverse steps 1 through 7 to replace the optical device/diskette drive assembly backplane. 2-20 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Figure 2-15: Removing the user interface board Reverse steps 1 through 6 to replace the user interface board. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-21 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Reverse steps 1 through 5 to replace the PCI riser board assembly, ensuring that the assembly seats properly in the retainers on the rear of the chassis. 2-22 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
IMPORTANT: Ensure that the expansion board is seated securely in the expansion slot before replacing the PCI riser board assembly and access panel. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-23 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Figure 2-18: Removing the PCI card guide Reverse steps 1 through 6, omitting step 5, to replace a PCI card guide. 2-24 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
4. Disconnect the center wall fan cables from the fan connectors on the system board. Figure 2-19: Disconnecting the center wall fan cables (processor removed for clarity) HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-25 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 37
Figure 2-21: Clearing the center wall alignment tab Reverse steps 1 through 8, omitting step 6, to replace the center wall. 2-26 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Table 2-3: System Fans Item Component Fan 1 Fan 2 Fan 3 Fan 4 Power supply fans HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-27 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Figure 2-23: Disconnecting the two-device terminated SCSI cable Reverse steps 1 through 6 to replace the two-device terminated SCSI cable. 2-28 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Figure 2-24: Disconnecting the ATA cables Reverse steps 1 through 6 to replace the ATA cables. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-29 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Reverse steps 1 through 6 to replace the optical device/diskette drive assembly cable. 2-30 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Figure 2-26: Removing the power supply Reverse steps 1 through 8 to replace the power supply. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-31 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
IMPORTANT: Run the ROM-Based Setup Utility (RBSU) to configure the system after replacing the battery. Refer to the HP Servers Troubleshooting Guide or setup and installation guide for more information.
Page 44
Reverse steps 1 through 6 to replace the battery, ensuring that the new battery is installed with the positive side up. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-33 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Item Description DIMM socket 1 DIMM socket 2 DIMM socket 3 DIMM socket 4 (populated) 2-34 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 46
5. Align the key slot in the bottom edge of the DIMM with the tab in the expansion socket. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-35 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 47
7. Press down firmly on the DIMM while pushing the latches inward until the latches snap into place. 2-36 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
POST. This error prevents the system from functioning properly. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-37 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 49
5. Remove the heatsink from the top of the processor. Figure 2-33: Removing the heatsink (both retaining clips disengaged) 2-38 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 50
CAUTION: Always use a new heatsink when replacing processors. Failure to use new components may result in damage to the processor. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-39 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
10. Disconnect the SCSI or ATA drive cables from the hard drives. See “Hard Drives” in this chapter. 11. Remove the system battery. See “Battery” in this chapter. 2-40 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 52
13. Identify the alignment keys and keyhole locations, 1 through 6, on the system board. Figure 2-35: Identifying system board alignment keys and keyhole locations HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-41 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
Page 53
Figure 2-36: Removing the system board Reverse steps 1 through 14 to replace the system board. 2-42 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
HP ProLiant DL320 reporting and graphing. Generation 2 Server Setup and Installation Guide. continued HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:41 AM...
Page 55
• Insight Manager appropriate drivers. • Survey Utility • LX32 Enterprise Diagnostics continued HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:41 AM...
Page 56
A utility that upgrades the current Run this utility from the system ROM. ROMPaq diskette after powering up the system unit. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:41 AM...
LED indicator locations on the front panel, rear panel, system board, and hard drives for the HP ProLiant DL320 Generation 2 server. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
RJ-45 Fast Ethernet connector for NIC 1 (supports PXE) Mouse connector Serial connector Video connector Keyboard connector USB 1 connector USB 2 connector HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
DIMM socket 2 Fan 1 connector DIMM socket 3 Fan 2 connector DIMM socket 4 (populated) HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
Figure 4-4: System switches Table 4-4: System Switches Item Description System configuration switch (SW1) Non-maskable interrupt (NMI) switch HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
The NMI switch is used only in the event of a service emergency that requires a complete data dump in preparation for recovering the system from a catastrophic failure. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
Off = Deactivated NIC 2 link/activity On = Link Off = No link Blinking = Activity continued HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
Page 64
Amber = Standby Off = Power off Optical drive activity On = Activity Off = No activity HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
Blinking = Activity Rear unit identification LED On = Local management Blinking = Remote management Off = Deactivated HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
Figure 4-7: Power status LEDs Item Description Power supply Auxiliary power supply 4-10 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
— Ultra3 SCSI hard drives — ATA hard drives • NC7760 Fast Ethernet NIC 10/100/1000 Wake On LAN HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
Storage maximum humidity of 95 percent based on maximum temperature of 45°C (113°F). Altitude minimum for storage is 70 kpa. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
CAS Latency 2, or greater. They must also contain the mandatory Joint Electronic Device Engineering Council (JEDEC) Serial Presence Detect (SPD). Use HP supplied SDRAM only. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
174 ms/94 ms Settling time 15 ms Latency average 100 ms Cylinders (high/low) 80/80 Read/write heads HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
Operating conditions Temperature 5° to 45°C (41° to 118°F) Humidity 5% to 90% (10% to 80%) HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
5° to 55°C (41° to 131°F) / -30° to 60°C (-22° to 140°F) Humidity 10% to 80% / 5% to 90% HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
133 MBps SCSI port connectors (internal) 68-pin Ultra3 SCSI connector Protocol Wide Ultra3 SCSI Software upgradeable firmware HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
UDMA Modes 5/4/3/2/1/0, DMA Modes 2/1/0, PIO Modes 4/3/2/1/0 Protocol ATA/100 compatible Feature CRC (Cyclical Redundancy Check) Buffer size 128 byte HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
Operating temperature Celsius 10° to 35° 10° to 35° Fahrenheit 50° to 95° 50º to 95° HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
Operating temperature Celsius 10° to 35° 10° to 35° Fahrenheit 50° to 95° 50º to 95° 5-10 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
Connector RJ-45 I/O address and interrupt Plug and Play PCI Emissions standards FCC class A HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 5-11 HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
4-2 cautions 2-32 connectors, switches, and LEDs 4-2 reconfiguring 2-32 country kit, part numbers 1-4 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide Index-1 HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...
Page 79
2-31 center wall 2-25 SCSI cable 2-28 connectors 4-4 shipping/ejector key 2-8 Index-2 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...
Page 80
LX32 enterprise diagnostics, description 3-1 PCI boards, configuring automatically 3-3 PCI card guide 2-24 installing 2-24 removing 2-24 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide Index-3 HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...
Page 81
1-4 jumper settings 2-15 removal and replacement procedures 2-1 to 2-42 LEDs, activity 4-8 Index-4 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...
Page 82
USB 1 connector 4-2 Power On/Off 2-6 USB 2 connector 4-2 system configuration switch (SW1), function 4-6 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide Index-5 HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...
Page 83
Integrated Management Log (IML) 3-2 ROM-Based Setup Utility (RBSU), description 3-3 ROM-Based Setup Utility (RBSU), running 3-3 Index-6 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...