HP ProLiant DL320 Maintenance And Service Manual

Generation 2
Hide thumbs Also See for ProLiant DL320:
Table of Contents

Quick Links

HP ProLiant DL320 Generation 2 Server
Maintenance and Service Guide
April 2003 (Second Edition)
Part Number 293164-002
HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM
Table of Contents
loading

Summary of Contents for HP ProLiant DL320

  • Page 1 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide April 2003 (Second Edition) Part Number 293164-002 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM...
  • Page 2 “as is” without warranty of any kind and is subject to change without notice. The warranties for HP products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.
  • Page 3: Table Of Contents

    User Interface Board ..........................2-21 PCI Riser Board Assembly........................2-22 Expansion Board..........................2-23 PCI Card Guide..........................2-24 Center Wall.............................. 2-25 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM...
  • Page 4 Ultra3 SCSI Hard Drives........................5-9 ATA Hard Drives ..........................5-10 Integrated NC7760 Gigabit Server Auto-Switching Network Interface Controller (NIC) ......5-11 Index HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM...
  • Page 5: About This Guide

    Improper repairs can create conditions that are hazardous. Audience Assumptions This guide is for service technicians. HP assumes you are qualified in the servicing of computer equipment, trained in recognizing hazards in products with hazardous energy levels, and familiar with weight and stability precautions for rack installations.
  • Page 6 AC power cord into a properly grounded AC outlet only. NOTE: Any indications of component replacement or printed wiring board modifications may void any warranty. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM...
  • Page 7: Where To Go For Additional Help

    In the United States and Canada, call 1-800-652-6672. • Outside the United States and Canada, refer to www.hp.com HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:32 AM...
  • Page 8: Illustrated Parts Catalog

    Illustrated Parts Catalog This chapter provides the illustrated parts breakdown and spare parts list for the HP ProLiant DL320 Generation 2 server. The table in this chapter provides names and ordering numbers for all referenced spare parts. Mechanical Parts Exploded View...
  • Page 9: System Components Exploded View

    Illustrated Parts Catalog System Components Exploded View Figure 1-2: System components exploded view HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:34 AM...
  • Page 10: Mechanical Parts And System Components Spares List

    DVD-ROM/diskette drive assembly* 269046-001 c) ATA hard drive, 80 GB 287685-001 * Not shown continued HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:34 AM...
  • Page 11 Sliding rails and cable management system kit* 177852-001 Telco rack-mounting kit* 177853-001 Third-party cabinet rack-mounting kit* 177854-001 * Not shown HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:34 AM...
  • Page 12: Removal And Replacement Procedures

    Removal and Replacement Procedures This chapter provides subassembly and module-level removal and replacement procedures for HP ProLiant DL320 Generation 2 servers. After completing all necessary removal and replacement procedures, run the diagnostics program to verify that all components operate properly.
  • Page 13: Symbols On Equipment

    WARNING: When installing the server in a telco rack, make certain that the rack frame is adequately secured to the building structure at the top and bottom. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 14: Server Warnings And Precautions

    — SCSI hard drives • Single Channel Wide Ultra3 SCSI controller module • Integrated ATA RAID controller module HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 15 — Optical device/diskette drive assembly cable • Power supply • Battery • Memory modules • Processor • System board HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 16: Powering Down The Server

    For information on this system utility, refer to the NTREADME.HLP file on Diskette 1 of the NT Software Support Diskettes. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 17: Access Panel

    CAUTION: Electrostatic discharge can damage electronic components. Ensure proper grounding before beginning any installation procedure. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 18 Figure 2-1: Removing the access panel To replace the access panel, reverse steps 1 through 3. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 19: Shipping/Ejector Key

    Figure 2-2: Removing the shipping/ejector key Reverse steps 1 through 3 to replace the shipping/ejector key. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 20: Bezel Blank

    To replace the bezel blank, slide the blank into the empty bay until it locks into place. Store the shipping/ejector key in the chassis or other safe location for future use. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 21: Optical Device/Diskette Drive Assembly

    To replace the assembly, slide the assembly into the bay until it is fully seated. 2-10 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 22: Fully Seated Optical Device/Diskette Drive Assembly

    Figure 2-5. Otherwise, store the shipping/ejector key inside the chassis for future use. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-11 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 23: Bezel

    4. Remove the four screws that secure the bezel to each side of the chassis. Figure 2-6: Removing the bezel screws 2-12 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 24 To install the bezel, reverse steps 1 through 7, omitting step 5. When the bottom of the bezel is hooked securely in place, the bezel top snaps into the chassis tabs. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-13 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 25: Hard Drive Overview

    ATA hard drives to Cable-Select mode, if they are not already set in Cable-Select mode. 2-14 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 26: Guidelines For Installing Scsi Hard Drives

    IMPORTANT: Always populate hard drive bays starting with the lowest ATA device number or recommended SCSI ID number. Figure 2-8: ATA device numbers or recommended SCSI ID numbers HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-15 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 27: Hard Drives

    Description ATA secondary controller connector Secondary drive cable ATA primary controller connector Primary drive cable 2-16 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 28 Slide the tray toward the rear of the server and lift the tray out of the chassis (2). Figure 2-11: Removing the hard drive tray from the chassis HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-17 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 29 Reverse steps 1 through 7 to replace the hard drive. 2-18 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 30: Single Channel Wide Ultra3 Scsi Controller Module

    To replace the SCSI module, reverse steps 1 through 4, ensuring that the SCSI module seats securely on the support posts. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-19 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 31: Optical Device/Diskette Drive Assembly Backplane

    (center wall removed for clarity) Reverse steps 1 through 7 to replace the optical device/diskette drive assembly backplane. 2-20 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 32: User Interface Board

    Figure 2-15: Removing the user interface board Reverse steps 1 through 6 to replace the user interface board. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-21 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 33: Pci Riser Board Assembly

    Reverse steps 1 through 5 to replace the PCI riser board assembly, ensuring that the assembly seats properly in the retainers on the rear of the chassis. 2-22 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 34: Expansion Board

    IMPORTANT: Ensure that the expansion board is seated securely in the expansion slot before replacing the PCI riser board assembly and access panel. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-23 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 35: Pci Card Guide

    Figure 2-18: Removing the PCI card guide Reverse steps 1 through 6, omitting step 5, to replace a PCI card guide. 2-24 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 36: Center Wall

    4. Disconnect the center wall fan cables from the fan connectors on the system board. Figure 2-19: Disconnecting the center wall fan cables (processor removed for clarity) HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-25 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 37 Figure 2-21: Clearing the center wall alignment tab Reverse steps 1 through 8, omitting step 6, to replace the center wall. 2-26 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 38: Fans

    Table 2-3: System Fans Item Component Fan 1 Fan 2 Fan 3 Fan 4 Power supply fans HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-27 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 39: Cables

    Figure 2-23: Disconnecting the two-device terminated SCSI cable Reverse steps 1 through 6 to replace the two-device terminated SCSI cable. 2-28 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 40: Ata Cables

    Figure 2-24: Disconnecting the ATA cables Reverse steps 1 through 6 to replace the ATA cables. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-29 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 41: Optical Device/Diskette Drive Assembly Cable

    Reverse steps 1 through 6 to replace the optical device/diskette drive assembly cable. 2-30 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 42: Power Supply

    Figure 2-26: Removing the power supply Reverse steps 1 through 8 to replace the power supply. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-31 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 43: Battery

    IMPORTANT: Run the ROM-Based Setup Utility (RBSU) to configure the system after replacing the battery. Refer to the HP Servers Troubleshooting Guide or setup and installation guide for more information.
  • Page 44 Reverse steps 1 through 6 to replace the battery, ensuring that the new battery is installed with the positive side up. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-33 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 45: Memory Modules

    Item Description DIMM socket 1 DIMM socket 2 DIMM socket 3 DIMM socket 4 (populated) 2-34 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 46 5. Align the key slot in the bottom edge of the DIMM with the tab in the expansion socket. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-35 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 47 7. Press down firmly on the DIMM while pushing the latches inward until the latches snap into place. 2-36 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 48: Processor

    POST. This error prevents the system from functioning properly. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-37 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 49 5. Remove the heatsink from the top of the processor. Figure 2-33: Removing the heatsink (both retaining clips disengaged) 2-38 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 50 CAUTION: Always use a new heatsink when replacing processors. Failure to use new components may result in damage to the processor. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-39 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 51: System Board

    10. Disconnect the SCSI or ATA drive cables from the hard drives. See “Hard Drives” in this chapter. 11. Remove the system battery. See “Battery” in this chapter. 2-40 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 52 13. Identify the alignment keys and keyhole locations, 1 through 6, on the system board. Figure 2-35: Identifying system board alignment keys and keyhole locations HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-41 HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 53 Figure 2-36: Removing the system board Reverse steps 1 through 14 to replace the system board. 2-42 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM...
  • Page 54: Diagnostic Tools

    HP ProLiant DL320 reporting and graphing. Generation 2 Server Setup and Installation Guide. continued HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:41 AM...
  • Page 55 • Insight Manager appropriate drivers. • Survey Utility • LX32 Enterprise Diagnostics continued HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:41 AM...
  • Page 56 A utility that upgrades the current Run this utility from the system ROM. ROMPaq diskette after powering up the system unit. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:41 AM...
  • Page 57: Connectors, Switches, And Led Indicators

    LED indicator locations on the front panel, rear panel, system board, and hard drives for the HP ProLiant DL320 Generation 2 server. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
  • Page 58: Connectors

    RJ-45 Fast Ethernet connector for NIC 1 (supports PXE) Mouse connector Serial connector Video connector Keyboard connector USB 1 connector USB 2 connector HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
  • Page 59: Expansion Slot Connector

    Figure 4-2: Expansion slot connector Table 4-2: Expansion Slot Item Description Expansion board slot cover 64-bit 33-MHz PCI slot HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
  • Page 60: System Board Connectors

    DIMM socket 2 Fan 1 connector DIMM socket 3 Fan 2 connector DIMM socket 4 (populated) HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
  • Page 61: System Switches

    Figure 4-4: System switches Table 4-4: System Switches Item Description System configuration switch (SW1) Non-maskable interrupt (NMI) switch HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
  • Page 62: System Configuration Switch (Sw1)

    The NMI switch is used only in the event of a service emergency that requires a complete data dump in preparation for recovering the system from a catastrophic failure. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
  • Page 63: Led Indicators

    Off = Deactivated NIC 2 link/activity On = Link Off = No link Blinking = Activity continued HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
  • Page 64 Amber = Standby Off = Power off Optical drive activity On = Activity Off = No activity HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
  • Page 65: Rear Panel Led Indicators

    Blinking = Activity Rear unit identification LED On = Local management Blinking = Remote management Off = Deactivated HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
  • Page 66: Internal Led Indicator

    Figure 4-7: Power status LEDs Item Description Power supply Auxiliary power supply 4-10 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:42 AM...
  • Page 67: Specifications

    — Ultra3 SCSI hard drives — ATA hard drives • NC7760 Fast Ethernet NIC 10/100/1000 Wake On LAN HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 68: System Unit

    Storage maximum humidity of 95 percent based on maximum temperature of 45°C (113°F). Altitude minimum for storage is 70 kpa. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 69: Power Supply

    CAS Latency 2, or greater. They must also contain the mandatory Joint Electronic Device Engineering Council (JEDEC) Serial Presence Detect (SPD). Use HP supplied SDRAM only. HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 70: Optical Device/Diskette Drive Assembly

    174 ms/94 ms Settling time 15 ms Latency average 100 ms Cylinders (high/low) 80/80 Read/write heads HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 71: Low-Profile Ide Cd-Rom Drive

    Operating conditions Temperature 5° to 45°C (41° to 118°F) Humidity 5% to 90% (10% to 80%) HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 72: Low-Profile Ide Dvd-Rom Drive

    5° to 55°C (41° to 131°F) / -30° to 60°C (-22° to 140°F) Humidity 10% to 80% / 5% to 90% HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 73: Single Channel Wide Ultra3 Scsi Controller Module

    133 MBps SCSI port connectors (internal) 68-pin Ultra3 SCSI connector Protocol Wide Ultra3 SCSI Software upgradeable firmware HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 74: Integrated Ultra Ata/100 Controller

    UDMA Modes 5/4/3/2/1/0, DMA Modes 2/1/0, PIO Modes 4/3/2/1/0 Protocol ATA/100 compatible Feature CRC (Cyclical Redundancy Check) Buffer size 128 byte HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 75: Optional Hard Drives

    Operating temperature Celsius 10° to 35° 10° to 35° Fahrenheit 50° to 95° 50º to 95° HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 76: Ata Hard Drives

    Operating temperature Celsius 10° to 35° 10° to 35° Fahrenheit 50° to 95° 50º to 95° 5-10 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 77: Integrated Nc7760 Gigabit Server Auto-Switching Network Interface Controller (Nic)

    Connector RJ-45 I/O address and interrupt Plug and Play PCI Emissions standards FCC class A HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 5-11 HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:44 AM...
  • Page 78: Index

    4-2 cautions 2-32 connectors, switches, and LEDs 4-2 reconfiguring 2-32 country kit, part numbers 1-4 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide Index-1 HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...
  • Page 79 2-31 center wall 2-25 SCSI cable 2-28 connectors 4-4 shipping/ejector key 2-8 Index-2 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...
  • Page 80 LX32 enterprise diagnostics, description 3-1 PCI boards, configuring automatically 3-3 PCI card guide 2-24 installing 2-24 removing 2-24 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide Index-3 HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...
  • Page 81 1-4 jumper settings 2-15 removal and replacement procedures 2-1 to 2-42 LEDs, activity 4-8 Index-4 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...
  • Page 82 USB 1 connector 4-2 Power On/Off 2-6 USB 2 connector 4-2 system configuration switch (SW1), function 4-6 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide Index-5 HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...
  • Page 83 Integrated Management Log (IML) 3-2 ROM-Based Setup Utility (RBSU), description 3-3 ROM-Based Setup Utility (RBSU), running 3-3 Index-6 HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: MoonStar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:46 AM...