beautypg.com
Manuals
Brands
GE Manuals
Measuring Instruments
Moisture Image 1 Series
GE Moisture Image 1 Series Manuals
Manuals and User Guides for GE Moisture Image 1 Series. We have
3
GE Moisture Image 1 Series manuals available for free PDF download: Programming Manual, Startup Manual, Service Manual
GE
Moisture Image Series 1
Startup Manual
GE Moisture Image 1 Series Startup Manual (111 pages)
Hygrometer
Brand:
GE
| Category:
Measuring Instruments
| Size: 2.18 MB
Table of Contents
Table of Contents
6
Installation
9
Introduction
10
Unpacking the Series 1
10
Delta F Oxygen Cell Drains
11
Checking the Delta F Oxygen Cell for Leakage
11
Delta F Oxygen Cell Water Level Window
12
Checking the Delta F Oxygen Cell for Leakage (Cont.)
12
Choosing a Site
13
Low Voltage Directive
13
BASEEFA Certification
13
CSA Certification
13
General Guidelines for Choosing a Site
14
Moisture/Temperature Probe Considerations
15
Temperature Range
15
Moisture Condensation
15
Static or Dynamic Use
16
Pressure
16
Long-Term Storage & Operational Stability
16
Freedom from Interference
16
Corrosive Materials
16
Sample System Guidelines
17
Moisture Sample Systems
17
A Typical Moisture Sample System
18
Oxygen Sample Systems
19
A Typical Oxygen Cell Sample System
20
Mounting the System
21
Mounting the Electronics Unit
21
Mounting the Sample System
21
Mounting the Oxygen Cell Assembly
21
Installing the Probes
22
Moisture Probes
22
Moisture Probe Installed in a Sample Cell
22
Pressure Sensors
23
Delta F Oxygen Cell
24
Preparing the Oxygen Cell
25
Delta F Oxygen Cell Electrolyte
25
Making Electrical Connections
27
Making Channel Connections
27
Series 1 Back Panel
27
Connecting the Power
28
Installation Instructions for CE Mark Conformity
28
Wiring Modifications for CE Compliance
28
Connecting Moisture Probes
29
Moisture Probe Serial Number
29
M Series Probes
30
M Series Probe Cable Wiring Diagram
30
M Series Probe Connections
31
STD/TF Terminal Block Location
31
TF Series Probes
32
TF Series Probe Cable Wiring Diagram
32
TF Series Probe Connections
33
Moisture Image Series Probes
34
STD/TF Probe Terminal Block Location
34
Moisture Image Series Probe Assembly
34
Moisture Image Series Probe Connections
35
MIS PRB Terminal Block Location
35
MIS Probe Cable Wiring Diagram
36
Connecting the Delta F Oxygen Cell
37
Acceptable Cable Lengths for Delta F Ranges
37
OXYGEN Terminal Block
38
Standard Delta F Oxygen Cell Connections
39
Standard Delta F Oxygen Cell
39
Weatherproof Delta F Oxygen Cells
40
Weatherproof Delta F Oxygen Cell Connections
40
Weatherproof Delta F Oxygen Cell
40
Explosion-Proof Delta F Oxygen Cells
41
Explosion-Proof Oxygen Cell Connections
41
Explosion-Proof Delta F Oxygen Cell
41
Establishing a Gas Flow through the Oxygen Cell
43
Initial Setup
53
Using the Front Panel to Access Data
54
Powering up
55
Screen Matrix Format after Power up
55
Entering Data into the User Program
56
The Moisture Image Series 1 Front Panel
56
Screen and Key Functions
57
Screen Components
57
Entering the Passcode
58
Verifying and Entering Setup Data
59
Activating and Changing Probes
60
Entering the Probe Configuration Menu
60
Probe Configuration Menu
60
Verifying Probe Configuration Data
60
MIS Probe Configuration on Channel 1
61
Entering or Changing Probe Configuration Data
62
Probe Types
63
Entering Calibration Data
64
Entering the System Calibration Menu
64
Entering Moisture Probe Calibration Data
65
System Calibration Menu for Moisture
66
Entering Delta F Oxygen Cell Calibration Data
67
System Calibration Menu for Oxygen Cell
68
Entering High and Low Reference Values
69
Entering the Reference Menuu
69
Entering Moisture Reference Values
70
Reference Menu for Moisture
70
Entering the Delta F Oxygen Cell Reference Values
72
Oxygen Cell Reference Table
72
Reference Menu for the Delta F Cell
72
Displaying Measurements
74
Series 1 Matrix Format Screen
74
Assigned and Unassigned Boxes
75
Example of a Displayed Measurement
75
Measurement Modes and Units for the Series 1
76
Specifications
81
Overall Specifications
82
Moisture Measurement
83
Oxygen Measurement
84
Pressure Measurement
84
Temperature Measurement
84
Electronic Specifications
85
Output Specifications
86
Input Specifications
87
Probe Specifications
88
Moisture Image Series Probe
88
TF Series Probe
90
M Series Probe
92
External Pressure Transmitter (Optional)
95
Program Information List
97
Index
102
Moisture Image Series 1 Analyzer
105
Moisture Image Series 2 Analyzer
106
Moisture Monitor Series 3 Analyzer
106
GE
Moisture Image 1 Series
Programming Manual
GE Moisture Image 1 Series Programming Manual (125 pages)
Hygrometer
Brand:
GE
| Category:
Measuring Instruments
| Size: 1.17 MB
Table of Contents
Table of Contents
5
Chapter 1 : Features and Capabilities
9
Introduction to the Moisture Image Series 1
9
Series 1
9
Electronics Unit
9
BASEEFA Certification
11
CSA Certification
11
Probes
12
M Series and TF Series Moisture Probes
12
Moisture Image Series Probe
14
Delta F Oxygen Cell
15
Cabling
16
M Series and TF Series Probes
16
Moisture Image Series Probe
16
Delta F Oxygen Cells
16
Pressure Sensors
16
RS232 Communications Port
16
User Program
17
Chapter 2 : Basic Programming
20
Introduction
20
Getting Started
21
Powering up
21
Entering Data into the User Program
21
Screen and Key Functions
21
Entering the Passcode
21
Getting On-Line Help
21
Verifying and Entering Setup Data
27
Activating and Changing Probes
28
Entering Calibration Data
31
Entering High and Low Reference Values
40
Displaying Measurements
47
Setting up the Matrix Format
51
Setting up the Line Graph
54
Tagging the Inputs
56
Adjusting the Contrast of the Screen
59
Setting the Clock and Calendar
60
Chapter 3 : Advanced Programming
65
Introduction
65
Setting up the Recorders
65
Selecting Measurement Mode and Units for Recorders
66
Setting the Range for Recorders
67
Setting up the Alarms
68
Selecting the Measurement Mode, Units and High/Low Values for Alarms
69
Entering the Setpoint and Deadband Values for Alarms
69
Using Automatic Calibration
71
Entering Constants and User Functions
73
Entering User Constants
74
Specifying User Functions
75
Entering Saturation Constants
78
Using Computer Enhanced Response
79
Setting up the Data Logger
81
Viewing the Data Logger Status
82
Viewing Logged Data
82
Removing Logged Data
82
Entering Data Logger Settings
83
Configuring the Serial Port
86
Description of a Sample Output
88
Setting Error Processing
92
Procedure for Setting Error Processing
92
Loading New Software
94
Chapter 4 : Programming with Panaview
99
Introduction
99
Changing Measurement Modes and Units
99
Open the Meter Display Window
100
Change Meter Programming
102
Changing a Matrix Display to a Graph
104
Changing Alarm Settings
105
Changing Recorder Settings
107
Setting Recorder Values
107
Testing Recorder Outputs
108
Programming Error Handling
109
Programming User Functions
110
Entering User Tables
112
Entering Saturation Constants
113
GE Moisture Image 1 Series Service Manual (107 pages)
Hygrometer
Brand:
GE
| Category:
Measuring Instruments
| Size: 6.19 MB
Table of Contents
Table of Contents
5
Making Electrical Connections
10
Installation Instructions for CE Mark Conformity
11
Precautions for Modified or Non-GE Panametrics Cables
12
Connecting the Recorder Outputs
13
Accessing the Channel Cards
13
Setting the Switch Blocks
13
Replacing the Channel Card
14
Connecting the Recorders
14
Connecting the Alarms
15
Connecting Pressure Sensor Inputs
17
Connecting a Pressure Transducer
18
Connecting Pressure Transmitters
20
Accessing the Channel Cards
23
Replacing the Channel Card
24
Connecting Auxiliary Inputs (Optional)
25
Connecting a Personal Computer or Printer
27
Setting the RS232 Switch
27
Connecting the PC or Printer
28
Performing an MH Calibration Test/Adjustment
29
Performing an MH Calibration Test/ Adjustment
29
Preliminary Steps
29
Calibration Procedure
29
Introduction
33
Testing the Alarm Relays
34
Testing the Recorder Outputs
35
Procedure for Testing the Recorder Output
36
Trimming Recorder Outputs
37
Preliminary Steps
37
Procedure for Trimming the Zero Value
38
Procedure for Trimming the Span Value
41
Screen Messages
42
Common Problems
44
Checking/ Replenishing the Delta F Oxygen Cell Electrolyte
46
Adding or Removing a PCMCIA Card
48
Procedure for Adding or Removing a PCMCIA Card
48
Installing a Channel Card
51
Replacing and Recalibrating the Moisture Probes
52
Recalibrating the Pressure Sensors
52
Calibrating the Delta F Oxygen Cell
53
Displaying the Oxygen Content in Ppmv and Μa
53
Checking the Oxygen Cell Calibration
55
Entering the New Span Value
56
Delta F Oxygen Cell Background Gas Correction Factors
57
Correcting for Different Background Gases
57
Entering the Current Multiplier
58
Range Error Description
60
Signal Error Description
60
Calibration Error Description
60
Introduction
63
Moisture Monitor Hints
64
Pressure
65
Response Time
65
Temperature
66
Flow Rate
66
Contaminants
67
Non-Conductive Particulates
67
Conductive Particulates
68
Corrosive Particulates
68
Aluminum Oxide Probe Maintenance
69
Corrosive Gases and Liquids
71
Materials of Construction
72
Calculations and Useful Formulas in Gas Applications
73
Nomenclature
73
Parts Per Million by Volume
74
Parts Per Million by Weight
75
Relative Humidity
75
Weight of Water Per Unit Volume of Carrier Gas
75
Weight of Water Per Unit Weight of Carrier Gas
76
Comparison of PPMV Calculations
83
Liquid Applications
84
Theory of Operation
84
Moisture Content Measurement in Organic Liquids
84
Empirical Calibrations
90
Solids Applications
96
Related Products
GE IC694PSM001-AB
GE IC694ACC200-A
GE Moisture Target Series 6
GE imagine
GE IM-4A
GE IM4D
GE IM4LED
GE IM4
GE IM6
GE IM-5D
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals