SERVICE MANUAL 4 HW60-1201/S/B Chapter 1 General Information 1-1. General Guidelines When servicing,observe the original lead dress.If a short circuit is found, replace all parts which are overheated or damaged by the short circuit.After servicing ,see to it that all the protective devices such as insulation barriers ,insulation papers shields are properly installed .Confirm that the screws,parts and wiring which were removed in order to service are put in the original positions, or whether there are the portions which are deteriorated around the service places serviced or not.
SERVICE MANUAL 5 HW60-1201/S/B Chapter 2 Product Feature 2-1. Features (1). 320mm diameter porthole, door may be open at a 175 degrees. Facilitate view of wash process, facilitate unloading and easy to use with large port. (2). Class A energy-saving Scientific design for tub can reduce the use of water heavy during washing, consequently upgrade the energy efficiency class to A,also use scientific washing (3).
Page 6
Product identification Description of appliance Washing machine Type of appliance(FS = standing, BI = built-in) Supplier own brand HAIER Supplier bar code(Europe) EAN Supplied by HAIER Commercial Brand / Model HAIER Commercial bar code Key-Features Energy efficiency class Washing performance class...
Page 7
SERVICE MANUAL 7 HW60-1201/S/B Auto water cool-down (before drain 90°C boiled water) Water overflow protection Acqua Stop kit Child protection Programs n° 1) Strong action /cotton cycles (90°C/60°C/40°C/30°C/※) n° 2) Normal action / synthetics (90°C/60°C/40°C/30°C/※) n° 3) Delicate action / wool or cashmere cycles (60°C/40°C/30°C/※) n°...
SERVICE MANUAL 17 HW60-1201/S/B 8-4. Joining the Inlet Hose to the Washing Machine 8-5. Drainage Hose 8-6. Connecting to the Power Supply Front Load Washing Machine...
SERVICE MANUAL HW60-1201/S/B Chapter 9 Wiring circuit and Self check 9-1. Wiring circuit Water level sensor FUSE Motor FUSE Front Load Washing Machine...
SERVICE MANUAL HW60-1201/S/B 9-2. Self check Self check 1. How to start Press the "Delay" and " intense” button at the same time, then plug on the machine, "tESt" and the model No will be displayed by turn. Press “start” button, the machine will start a self test program. At first, the model of the machine will be displayed, then the following will be performed.
SERVICE MANUAL 20 HW60-1201/S/B Chapter 10 Error Display and troubleshooting 10-1. Error Display Error message:Door is not properly shut 20s after program is started. Troubleshooting: Shut the door properly Pushing the door to Check Whether Door is properly shut or not Door lock is broken and need replacing, Cut off the power and then turn on again.
SERVICE MANUAL 21 HW60-1201/S/B Error message:Temperature sensor is not properly connected or damaged Troubleshooting: Cut off power and measure the resistance NTC exist open circuit. Replace it multimeter of temperature sensor by , is it between 5-14kΩ ? Check if NTC is connected properly Connect NTC well Check the white wire and black wire of NTC, are they connected well?
Page 22
SERVICE MANUAL 22 HW60-1201/S/B Error message: The required water level is not reached within 6 min Troubleshooting: Connect it well. Check if water is leaking from washer bottom. Inlet pipe. drain pipe or other pipe connection Check if tap is closed or water Open the tap or wait for normal water pressure (usual...
Page 23
SERVICE MANUAL HW60-1201/S/B Put the motor in normal temperature Measure if the resistance of motor about ten minutes, and then test binding by multimeter, is it as followed? again. If the resistance is natural, it [1.78±8%Ω (at 20 C)] 5 -10 is caused by overheated protection.
Page 24
SERVICE MANUAL HW60-1201/S/B Without power ,connect inlet pipe to inlet Replace inlet valve valve, then open the tap and observe if water is entering in dispenser Without starting but electrifying, measure Replace PCB the import voltage of inlet valve, is it between AC 220-240V? Error message: Water level sensor is unnormal.
SERVICE MANUAL 25 HW60-1201/S/B 10-2. Examination & Troubleshooting 10-2-1. Display nothing Troubleshooting: Repair power supply Measure the power supply ,is it exists 220V-240V AC voltage? Press the power switch Is power switch on? Make sure power supply cable Press power switch and check the assembly is connected well and then voltage between two pins of power replace power switch.
SERVICE MANUAL 26 HW60-1201/S/B Troubleshooting Adjust the height of drainpipe to Is the height of drain pipe too high? 80-100 cm Turn filter anticlockwise , open and check if filter is jammed Clean and tighten filter clockwise. Arrange hose and clean Check if hose-connecting cylinder to pump is bent or jammed Turn on power and choose spin...
SERVICE MANUAL 27 HW60-1201/S/B 10-2-5. Water leaking Troubleshooting: Check if water is leaking from the inlet pipe Readjust it or the tap Is drain pipe broken? Replace drainpipe Check if there is foreign material nipped Remove clothes between cushion of sight window and sight window Check if all tubes and tie-in is leaking water, including the connecting of tube...