Daikin 2MXS40H2V1B Service Manual page 248

Inverter multi for 2 rooms h-series / g-series
Hide thumbs Also See for 2MXS40H2V1B:
Table of Contents
Field Settings
Wireless Remote
1. Hold down the "
Controller
2. Press the "
(Factory Set is
"1")
3. Press the "
4. Press the "
5. Hold down the "
Multiple Settings
When the indoor is controlled by outside controller (central remote controller, etc.), it sometimes
A/b
does not respond to ON/OFF command or temperature setting command from the remote
controller. Check what setting the customer needs and make the multiple setting as shown
below.
Multiple Setting
A: Standard
b: Multiple display
237
" button and the "
4 seconds to enter the field setting mode. ("SETTING" is indicated on the display).
" button and select "A" or "b". Each time the button is pressed, the
display switches between "A" and "b".
" button and "
Address can be set from 1 ~ 6, but set it to 1 ~ 3 and to same address as the receiver. (The
receiver does not work with address 4 ~ 6.)
" button to confirm the setting.
return to the normal display.
Field setting mode
Address
Multiple setting
Remote Controller
Remote Controller
Display
All items are displayed. ON/OFF command and
Operations set only is
displayed shortly after
execution.
" button to set the address.
" button for at least 1 second to exit the field setting mode and
1
A
Controlled by other air
conditioners or devices
temperature setting
command cannot be
accepted. (1 long beep
or 3 short beeps
emitted)
All the commands can be accepted (2 short
beeps)
SiBE121123_A
" button at the same time for at least
(R14401)
Indoor Unit
Other condition
Trial Operation and Field Settings

Hide quick links:

Table of Contents
loading

Table of Contents